Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Feu, J.
Right arrow Articles by Alegret, X.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Feu, J.
Right arrow Articles by Alegret, X.

Radiology, Vol 205, 831-835, Copyright © 1997 by Radiological Society of North America


ARTICLES

Metastatic breast carcinoma in axillary lymph nodes: in vitro US detection

J Feu, F Tresserra, R Fabregas, B Navarro, PJ Grases, JC Suris, A Fernandez-Cid and X Alegret
Department of Radiology, Institut Universitari Dexeus, Barcelona, Spain.

PURPOSE: To establish the ultrasonographic (US) characteristics of benign versus metastatic lymph nodes. MATERIALS AND METHODS: One hundred fifty-eight axillary lymph nodes in 40 patients (age range, 31- 73 years) surgically treated for breast cancer have been studied in vitro with a 7.5-MHz US probe in a water bath. The long-to-short axis ratio and the hilar and cortical characteristics were evaluated; the US findings were correlated with the histopathologic findings. To estimate the long-to-short axis ratio, all lymph nodes were measured. RESULTS: Of the 158 lymph nodes, 45 showed histopathologic evidence of metastasis; 38 of the 45 revealed US signs of malignancy. The signs that caused malignancy to be suspected were a long-to-short axis ratio of less than 1.5, absence of a hilus, and disruption of the cortical zone. The most specific sign for the diagnosis of metastasis was absence of the hilus. The increase in the long-to-short axis ratio was the finding that caused the most false-negative interpretations. Signs of malignancy were more accurate in lymph nodes 10 mm or larger than they were in lymph nodes smaller than 10 mm. CONCLUSION: Findings of in vitro US studies of axillary adenopathy provide the basis for the evaluation of lymph node metastasis in vivo before surgery, especially in those lymph nodes 10 mm or larger.


This article has been cited by other articles:


Home page
BMJHome page
P. D Britton
Breast imaging
BMJ, September 17, 2008; 337(sep17_2): a1313 - a1313.
[Full Text]


Home page
Am. J. Roentgenol.Home page
D. G. Bedi, R. Krishnamurthy, S. Krishnamurthy, B. S. Edeiken, H. Le-Petross, B. D. Fornage, R. L. Bassett Jr., and K. K. Hunt
Cortical Morphologic Features of Axillary Lymph Nodes as a Predictor of Metastasis in Breast Cancer: In Vitro Sonographic Study
Am. J. Roentgenol., September 1, 2008; 191(3): 646 - 652.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
A MOORE, M HESTER, M-W NAM, Y M BRILL, P McGRATH, H WRIGHT, K WEISINGER, E ROMOND, and L M SAMAYOA
Distinct lymph nodal sonographic characteristics in breast cancer patients at high risk for axillary metastases correlate with the final axillary stage
Br. J. Radiol., August 1, 2008; 81(968): 630 - 636.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
J. L. Hinson, P. McGrath, A. Moore, J. T. Davis, Y. M. Brill, E. Samoilova, M. Cibull, M. Hester, E. Romond, K. Weisinger, et al.
The Critical Role of Axillary Ultrasound and Aspiration Biopsy in the Management of Breast Cancer Patients with Clinically Negative Axilla
Ann. Surg. Oncol., January 1, 2008; 15(1): 250 - 255.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
H. Abe, R. A. Schmidt, C. A. Sennett, A. Shimauchi, and G. M. Newstead
US-guided Core Needle Biopsy of Axillary Lymph Nodes in Patients with Breast Cancer: Why and How to Do It
RadioGraphics, October 1, 2007; 27(suppl_1): S91 - S99.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
J. H. Shin, H.-Y. Choi, B.-I. Moon, and S. H. Sung
In Vitro Sonographic Evaluation of Sentinel Lymph Nodes for Detecting Metastasis in Breast Cancer: Comparison With Histopathologic Results
J. Ultrasound Med., July 1, 2004; 23(7): 923 - 928.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
L. Rubaltelli, Y. Khadivi, A. Tregnaghi, R. Stramare, F. Ferro, S. Borsato, U. Fiocco, F. Adami, and C. R. Rossi
Evaluation of Lymph Node Perfusion Using Continuous Mode Harmonic Ultrasonography With a Second-Generation Contrast Agent
J. Ultrasound Med., June 1, 2004; 23(6): 829 - 836.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
I. Bedrosian, D. Bedi, H. M. Kuerer, B. D. Fornage, L. Harker, M. I. Ross, F. C. Ames, S. Krishnamurthy, B. S. Edeiken-Monroe, F. Meric, et al.
Impact of Clinicopathological Factors on Sensitivity of Axillary Ultrasonography in the Detection of Axillary Nodal Metastases in Patients With Breast Cancer
Ann. Surg. Oncol., November 1, 2003; 10(9): 1025 - 1030.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
I. Gunhan-Bilgen, E. E. Ustun, and A. Memis
Inflammatory Breast Carcinoma: Mammographic, Ultrasonographic, Clinical, and Pathologic Findings in 142 Cases
Radiology, June 1, 2002; 223(3): 829 - 838.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. T. Yang, J. Chang, and C. Metreweli
Patients with Breast Cancer: Differences in Color Doppler Flow and Gray-Scale US Features of Benign and Malignant Axillary Lymph Nodes
Radiology, May 1, 2000; 215(2): 568 - 573.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.