Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kanematsu, M.
Right arrow Articles by Nakamura, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kanematsu, M.
Right arrow Articles by Nakamura, H.

Radiology, Vol 206, 167-175, Copyright © 1998 by Radiological Society of North America


ARTICLES

Focal hepatic lesion detection: comparison of four T2-weighted MR imaging pulse sequences

M Kanematsu, H Hoshi, T Murakami, Y Inaba, M Hori, Y Nandate, R Yokoyama and H Nakamura
Department of Radiology, Gifu University School of Medicine, Japan.

PURPOSE: To evaluate T2-weighted magnetic resonance (MR) imaging with conventional spin-echo, breath-hold fast spin-echo, respiratory- triggered fast spin-echo, and breath-hold multishot spin-echo echo- planar sequences for detection of focal hepatic lesions. MATERIALS AND METHODS: T2-weighted MR images obtained with the four sequences in 56 patients with 107 solid and 124 nonsolid lesions were retrospectively analyzed. Image review was conducted on a liver segment-by-segment basis; a total of 408 liver segments were reviewed separately and independently for solid and nonsolid lesions by three radiologists. Diagnostic accuracy was evaluated with receiver operating characteristic analysis. RESULTS: Lesion-to-liver contrast-to-noise ratio was highest with multishot echo-planar images of both solid and nonsolid lesions. Diagnostic accuracy for solid lesions was statistically significantly better with conventional spin-echo images than with any other type of image (P < .0001). Diagnostic accuracy for nonsolid lesions was statistically significantly better with respiratory-triggered fast spin-echo images than with any other type of image (P < .0001). Image quality was best with breath-hold fast spin- echo images. CONCLUSION: Conventional spin-echo MR imaging should not be replaced with breath-hold fast spin-echo or multishot spin-echo echo- planar imaging, despite the shorter acquisition times that are possible with the latter two sequences.


This article has been cited by other articles:


Home page
RadiologyHome page
M. Kanematsu, S. Goshima, H. K. Hussain, T. D. Johnson, H. V. Nghiem, and I. R. Francis
Does T2-weighted MR Imaging Really Add No Value in Detection and Characterization of Focal Lesions in Cirrhotic Liver? * Dr Hussain and colleagues respond:
Radiology, February 1, 2005; 234(2): 638 - 640.
[Full Text]


Home page
RadiologyHome page
A. S. Arbab, T. Ichikawa, H. Sou, T. Araki, H. Nakajima, K. Ishigame, T. Yoshikawa, and H. Kumagai
Ferumoxides-enhanced Double-Echo T2-weighted MR Imaging in Differentiating Metastases from Nonsolid Benign Lesions of the Liver
Radiology, October 1, 2002; 225(1): 151 - 158.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Augui, O. Vignaux, C. Argaud, J. Coste, H. Gouya, and P. Legmann
Liver: T2-weighted MR Imaging with Breath-hold Fast-Recovery Optimized Fast Spin-Echo Compared with Breath-hold Half-Fourier and Non-Breath-hold Respiratory-triggered Fast Spin-Echo Pulse Sequences
Radiology, June 1, 2002; 223(3): 853 - 859.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. A. Bluemke, E. K. Paulson, M. A. Choti, S. DeSena, and P. A. Clavien
Detection of Hepatic Lesions in Candidates for Surgery: Comparison of Ferumoxides-Enhanced MR Imaging and Dual-Phase Helical CT
Am. J. Roentgenol., December 1, 2000; 175(6): 1653 - 1658.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Hori, T. Murakami, T. Kim, M. Kanematsu, K. Tsuda, S. Takahashi, M. Takamura, H. Hoshi, and H. Nakamura
Single Breath-Hold T2-Weighted MR Imaging of the Liver: Value of Single-Shot Fast Spin-Echo and Multishot Spin-Echo Echoplanar Imaging
Am. J. Roentgenol., May 1, 2000; 174(5): 1423 - 1431.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Kondo, M. Kanematsu, H. Hoshi, T. Murakami, T. Kim, M. Hori, M. Matsuo, and H. Nakamura
Preoperative Detection of Malignant Hepatic Tumors: Comparison of Combined Methods of MR Imaging with Combined Methods of CT
Am. J. Roentgenol., April 1, 2000; 174(4): 947 - 954.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Kanematsu, H. Hoshi, M. N. J. M. Wasser, M. E. J. Pijl, E. L. van Persijn van Meerten, J.-W. C. Gratama, and J. L. Bloem
Can Inversion-Recovery Gradient- and Spin-Echo T2-weighted MR Imaging Be an Alternative to Fast Spin-Echo Imaging with Fat Suppression? • Dr Wasser and colleagues respond:
Radiology, July 1, 1999; 212(1): 291 - 291.
[Full Text]


Home page
RadiologyHome page
M. Kanematsu, H. Hoshi, K. Itoh, T. Murakami, M. Hori, H. Kondo, R. Yokoyama, and H. Nakamura
Focal Hepatic Lesion Detection: Comparison of Four Fat-suppressed T2-weighted MR Imaging Pulse Sequences
Radiology, May 1, 1999; 211(2): 363 - 371.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. C. Semelka, N. C. Balci, B. O. de Beeck, and C. Reinhold
Evaluation of a 10-minute Comprehensive MR Imaging Examination of the Upper Abdomen
Radiology, April 1, 1999; 211(1): 189 - 195.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.