Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Doerfler, A.
Right arrow Articles by Forsting, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Doerfler, A.
Right arrow Articles by Forsting, M.

Radiology, Vol 206, 211-217, Copyright © 1998 by Radiological Society of North America


ARTICLES

Are iodinated contrast agents detrimental in acute cerebral ischemia? An experimental study in rats

A Doerfler, T Engelhorn, R von Kummer, J Weber, M Knauth, S Heiland, K Sartor and M Forsting
Department of Neuroradiology, University of Essen Medical School, Germany.

PURPOSE: To study the effects of iothalamate sodium and two dosages of iopromide in acute cerebral ischemia on infarction volume, neurologic performance, and mortality in a rat model of middle cerebral artery occlusion. MATERIALS AND METHODS: Sixty-four rats underwent endovascular occlusion of the middle cerebral artery. Four hours later, 16 animals received iothalamate sodium (588 mg iodine per kilogram); 16, iopromide as a single bolus (518 mg iodine per kilogram); and 16, iopromide as a double bolus (1,036 mg iodine per kilogram). Sixteen animals received equivolumetric saline (control group). Neurologic score and body weight were recorded every 8 hours. Twenty-four hours after occlusion, all animals were killed; brains were stained to assess the infarction size. RESULTS: Single and double doses of iopromide did not affect infarction volume or neurologic performance. Iothalamate caused an increase in infarction volume and worsening of the neurologic score (p < .05). Mortality rate was 25% in the iothalamate group, 12% in the control group, and 6% in the iopromide groups. CONCLUSION: Bolus injection of the nonionic iopromide does not statistically significantly affect infarction volume or cerebral ischemia symptoms. Nonionic rather than ionic contrast agents should be preferred during acute cerebral ischemia.


This article has been cited by other articles:


Home page
StrokeHome page
P. Khatri, J. P. Broderick, J. C. Khoury, J. A. Carrozzella, T. A. Tomsick, and for the IMS I and II Investigators
Microcatheter Contrast Injections During Intra-Arterial Thrombolysis May Increase Intracranial Hemorrhage Risk
Stroke, December 1, 2008; 39(12): 3283 - 3287.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Wintermark, W. S. Smith, N. U. Ko, M. Quist, P. Schnyder, and W. P. Dillon
Dynamic Perfusion CT: Optimizing the Temporal Resolution and Contrast Volume for Calculation of Perfusion CT Parameters in Stroke Patients
AJNR Am. J. Neuroradiol., May 1, 2004; 25(5): 720 - 729.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. G. Nabavi, S. P. Kloska, E.-M. Nam, M. Freund, C. G. Gaus, E. Klotz, W. Heindel, and E. B. Ringelstein
MOSAIC: Multimodal Stroke Assessment Using Computed Tomography: Novel Diagnostic Approach for the Prediction of Infarction Size and Clinical Outcome
Stroke, December 1, 2002; 33(12): 2819 - 2826.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
P. Schramm, P. D. Schellinger, J. B. Fiebach, S. Heiland, O. Jansen, M. Knauth, W. Hacke, and K. Sartor
Comparison of CT and CT Angiography Source Images With Diffusion-Weighted Imaging in Patients With Acute Stroke Within 6 Hours After Onset
Stroke, October 1, 2002; 33(10): 2426 - 2432.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
M. A. Ezzeddine, M. H. Lev, C. T. McDonald, G. Rordorf, J. Oliveira-Filho, F. G. Aksoy, J. Farkas, A. Z. Segal, L. H. Schwamm, R. G. Gonzalez, et al.
CT Angiography With Whole Brain Perfused Blood Volume Imaging: Added Clinical Value in the Assessment of Acute Stroke
Stroke, April 1, 2002; 33(4): 959 - 966.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Wintermark, J.-P. Thiran, P. Maeder, P. Schnyder, and R. Meuli
Simultaneous Measurement of Regional Cerebral Blood Flow by Perfusion CT and Stable Xenon CT: A Validation Study
AJNR Am. J. Neuroradiol., May 1, 2001; 22(5): 905 - 914.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
T. E. Mayer, G. F. Hamann, J. Baranczyk, B. Rosengarten, E. Klotz, M. Wiesmann, U. Missler, G. Schulte-Altedorneburg, and H. J. Brueckmann
Dynamic CT Perfusion Imaging of Acute Stroke
AJNR Am. J. Neuroradiol., August 1, 2000; 21(8): 1441 - 1449.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. von Kummer, N. J. Beauchamp Jr, P. B. Barker, P. Y. Wang, and P. C. M. vanZijl
CT of Acute Cerebral Ischemia Dr Beauchamp and colleagues respond:
Radiology, August 1, 2000; 216(2): 611 - 613.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.