|
|
||||||||
Radiology, Vol 206, 45-48, Copyright © 1998 by Radiological Society of North America
ARTICLES |
JA Jacobson, A Powell, JG Craig, JA Bouffard and MT van Holsbeeck
Department of Radiology, Henry Ford Hospital, Detroit, MI 48202, USA.
PURPOSE: To evaluate the use of ultrasound (US) for detection of wooden foreign bodies implanted in cadaveric specimens. MATERIALS AND METHODS: Wooden foreign bodies were randomly placed in the plantar soft tissues of three cadaver feet by using 5-mm-long incisions. Ten foreign bodies were 2.5 x 1.0 mm (length x diameter); 10 were 5.0 x 1.0 mm. Ten incisions were performed without implantation of foreign bodies. Three musculoskeletal radiologists independently performed US in blinded fashion and recorded the presence of a foreign body. Each used 7.5- and 10-MHz linear-array transducers and was informed of the possible presence of a foreign body. RESULTS: Sensitivity and specificity for detection of 2.5-mm-long foreign bodies were 86.7% and 96.7%, respectively. Sensitivity and specificity for detection of 5.0-mm-long foreign bodies were 93.3% and 96.7%, respectively. Overall sensitivity was 90.0%, with specificity of 96.7%, accuracy of 92.3%, positive predictive value of 98.0%, and negative predictive value of 83.0%. CONCLUSION: US can be used effectively to locate wooden foreign bodies as small as 2.5 mm in length. Given that many foreign bodies are radiographically undetectable, the accuracy and availability of US make it an excellent modality for evaluation of radiolucent foreign bodies.
This article has been cited by other articles:
![]() |
S. Asad, K. Bae, K.-N. Jeon, J.-M. Cho, T.-B. Shin, Y.-T. Joo, and H.-J. Kim Appendicitis Caused by a Foreign Body of Dental Origin: Diagnosis With Ultrasonography J. Ultrasound Med., July 1, 2007; 26(7): 967 - 970. [Full Text] [PDF] |
||||
![]() |
D. L. Isaacs Detection of a Ballpoint Pen in a Patient's Abdomen by Sonography. J. Ultrasound Med., August 1, 2006; 25(8): 1095 - 1098. [Full Text] [PDF] |
||||
![]() |
T. S. Gibbs The Use of Sonography in the Identification, Localization, and Removal of Soft Tissue Foreign Bodies Journal of Diagnostic Medical Sonography, January 1, 2006; 22(1): 5 - 21. [Abstract] [PDF] |
||||
![]() |
K. C. Davae, C. M. Sofka, E. DiCarlo, and R. S. Adler Value of Power Doppler Imaging and the Hypoechoic Halo in the Sonographic Detection of Foreign Bodies: Correlation With Histopathologic Findings J. Ultrasound Med., December 1, 2003; 22(12): 1309 - 1313. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Soudack, A. Nachtigal, and D. Gaitini Clinically Unsuspected Foreign Bodies: The Importance of Sonography J. Ultrasound Med., December 1, 2003; 22(12): 1381 - 1385. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. P. Fessell, D. A. Jamadar, J. A. Jacobson, E. M. Caoili, Q. Dong, S. S. Pai, and M. T. van Holsbeeck Sonography of Dorsal Ankle and Foot Abnormalities Am. J. Roentgenol., December 1, 2003; 181(6): 1573 - 1581. [Full Text] [PDF] |
||||
![]() |
G. Moschilla and W. Breidahl Sonography of the Finger Am. J. Roentgenol., June 1, 2002; 178(6): 1451 - 1457. [Full Text] [PDF] |
||||
![]() |
T. D. Boyse, D. P. Fessell, J. A. Jacobson, J. Lin, M. T. van Holsbeeck, and C. W. Hayes US of Soft-Tissue Foreign Bodies and Associated Complications with Surgical Correlation RadioGraphics, September 1, 2001; 21(5): 1251 - 1256. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. K. Horton, J. A. Jacobson, A. Powell, D. P. Fessell, and C. W. Hayes Sonography and Radiography of Soft-Tissue Foreign Bodies Am. J. Roentgenol., May 1, 2001; 176(5): 1155 - 1159. [Full Text] [PDF] |
||||
![]() |
J. Lin, J. A. Jacobson, D. P. Fessell, W. J. Weadock, and C. W. Hayes An Illustrated Tutorial of Musculoskeletal Sonography: Part 4, Musculoskeletal Masses, Sonographically Guided Interventions, and Miscellaneous Topics Am. J. Roentgenol., December 1, 2000; 175(6): 1711 - 1719. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |