Radiology, Vol 206, 711-715, Copyright © 1998 by Radiological Society of North America
ARTICLES |
L Liberman, DD Dershaw, PP Rosen, EA Morris, AF Abramson and PI Borgen
Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021, USA.
PURPOSE: To determine whether complete percutaneous removal of a malignant lesion detected at mammography ensures complete excision of the carcinoma histopathologically. MATERIALS AND METHODS: A retrospective review was performed of 135 lesions in which stereotactic biopsy was performed with a directional, vacuum biopsy instrument and an 11-gauge probe followed by mammography. Carcinoma was diagnosed at stereotactic biopsy in 51 (38%) lesions. In 15 (29%) carcinomas, the lesion seen at mammography was removed at stereotactic biopsy. Surgical findings were available for correlation with biopsy and imaging findings in all 15 cases. Mammographic and histopathologic findings were reviewed. RESULTS: Mammographic findings were calcifications in 11 lesions and a mass in four lesions. The median lesion size was 0.7 cm (range, 0.2-1.4 cm), and the median number of biopsy specimens was 15 (range, 10-22 specimens). Histopathologic findings at stereotactic biopsy were ductal carcinoma in situ in 12 lesions and infiltrating ductal carcinoma in three. Surgery revealed residual carcinoma in 11 (73%) of 15 lesions, including all three infiltrating ductal carcinomas and eight of 12 ductal carcinoma in situ lesions. CONCLUSION: Complete removal of the mammographic lesion does not ensure complete excision of the carcinoma.
This article has been cited by other articles:
![]() |
A. P. Lourenco, M. B. Mainiero, E. Lazarus, D. Giri, and B. Schepps Stereotactic Breast Biopsy: Comparison of Histologic Underestimation Rates with 11- and 9-Gauge Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., November 1, 2007; 189(5): W275 - W279. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy Radiology, September 1, 2004; 232(3): 897 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Birdwell and R. J. Jackman Clip or Marker Migration 5-10 Weeks after Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Report of Two Cases Radiology, November 1, 2003; 229(2): 541 - 544. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. E. March, B. F. Coughlin, R. B. Barham, R. A. Goulart, S. V. Klein, M. E. Bur, J. L. Frank, and G. Makari-Judson Breast Masses: Removal of All US Evidence during Biopsy by Using a Handheld Vacuum-assisted Device--Initial Experience Radiology, May 1, 2003; 227(2): 549 - 555. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, J. B. Kaplan, E. A. Morris, A. F. Abramson, J. H. Menell, and D. D. Dershaw To Excise or To Sample the Mammographic Target: What Is the Goal of Stereotactic II-Gauge Vacuum-Assisted Breast Biopsy? Am. J. Roentgenol., September 1, 2002; 179(3): 679 - 683. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Perez-Fuentes, I. R. Longobardi, V. F. Acosta, C. E. Marin, and L. Liberman Sonographically Guided Directional Vacuum-Assisted Breast Biopsy: Preliminary Experience in Venezuela Am. J. Roentgenol., December 1, 2001; 177(6): 1459 - 1463. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Guenin, M. L. R. Darling, D. N. Smith, and S. C. Lester Less Is Not More in Stereotactic Biopsy Am. J. Roentgenol., July 1, 2001; 177(1): 250 - 251. [Full Text] [PDF] |
||||
![]() |
R. F. Brem, J. M. Schoonjans, S. N. Goodman, A. Nolten, F. B. Askin, and O. M. B. Gatewood Nonpalpable Breast Cancer: Percutaneous Diagnosis with 11- and 8-gauge Stereotactic Vacuum-assisted Biopsy Devices Radiology, June 1, 2001; 219(3): 793 - 796. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. L. R. Darling, D. N. Smith, S. C. Lester, C. Kaelin, D.-L. G. Selland, C. M. Denison, P. J. DiPiro, D. I. Rose, E. Rhei, and J. E. Meyer Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision Am. J. Roentgenol., November 1, 2000; 175(5): 1341 - 1346. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Philpotts, C. H. Lee, L. J. Horvath, R. C. Lange, D. Carter, and I. Tocino Underestimation of Breast Cancer with II-Gauge Vacuum Suction Biopsy Am. J. Roentgenol., October 1, 2000; 175(4): 1047 - 1050. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
R. J. Brenner Lesions Entirely Removed during Stereotactic Biopsy: Preoperative Localization on the Basis of Mammographic Landmarks and Feasibility of Freehand Technique-Initial Experience Radiology, February 1, 2000; 214(2): 585 - 590. [Abstract] [Full Text] |
||||
![]() |
R. J. Jackman, K. W. Nowels, J. Rodriguez-Soto, F. A. Marzoni Jr, S. I. Finkelstein, and M. J. Shepard Stereotactic, Automated, Large-Core Needle Biopsy of Nonpalpable Breast Lesions: False-Negative and Histologic Underestimation Rates after Long-term Follow-up Radiology, March 1, 1999; 210(3): 799 - 805. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |