|
|
||||||||
Radiology, Vol 206, 717-720, Copyright © 1998 by Radiological Society of North America
ARTICLES |
JE Meyer, DN Smith, SC Lester, PJ DiPiro, CM Denison, SC Harvey, RL Christian, A Richardson and WD Ko
Department of Radiology, Brigham and Women's Hospital, Boston, MA 02115, USA.
PURPOSE: To classify lesions initially considered nonmalignant at large- needle core biopsy that were subsequently surgically excised or sampled at repeat biopsy. MATERIALS AND METHODS: From August 1, 1991, to December 31, 1996, 1,032 breast abnormalities (214 malignant and 818 nonmalignant lesions) were sampled at large-needle core biopsy. Of the nonmalignant lesions, 112 (14%) abnormalities were studied. Twenty-four abnormalities were subsequently excised because of discordant imaging and pathologic findings; 41 may have been missed at biopsy (25 were surgically excised, and 16 were sampled at repeat biopsy); 40 were surgically excised as recommended by the pathologist; and seven were excised for other indications. RESULTS: None of 24 abnormalities excised because of discordant findings was malignant. Among the 41 possibly missed lesions, infiltrating ductal carcinoma was found in one lesion that was removed surgically and in one sampled at repeat biopsy. Among the 40 lesions recommended for excision by the pathologist, 16 malignancies were found (ductal carcinoma in situ, 11; infiltrating ductal carcinoma, three; phyllodes tumor, two). None of the remaining seven lesions was malignant. CONCLUSION: Correlation of the technical quality of the biopsy, imaging features, and pathologic findings resulted in 96 surgical excisions and 16 repeat biopsies of lesions initially considered nonmalignant. Eighteen additional malignancies were identified.
This article has been cited by other articles:
![]() |
G. Schueller, S. Jaromi, L. Ponhold, M. Fuchsjaeger, M. Memarsadeghi, M. Rudas, M. Weber, L. Liberman, and T. H. Helbich US-guided 14-gauge Core-Needle Breast Biopsy: Results of a Validation Study in 1352 Cases Radiology, August 1, 2008; 248(2): 406 - 413. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-M. Lee, J. B. Kaplan, M. P. Murray, L. Bartella, E. A. Morris, S. Joo, D. D. Dershaw, and L. Liberman Imaging Histologic Discordance at MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., October 1, 2007; 189(4): 852 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. F. Dillon, E. W. McDermott, A. D. Hill, A. O'Doherty, N. O'Higgins, and C. M. Quinn Predictive Value of Breast Lesions of "Uncertain Malignant Potential" and "Suspicious for Malignancy" Determined by Needle Core Biopsy Ann. Surg. Oncol., February 1, 2007; 14(2): 704 - 711. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis? Radiology, September 1, 2005; 236(3): 801 - 809. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. K. Komenaka, M. El-Tamer, E. Pile-Spellman, and H. Hibshoosh Core Needle Biopsy as a Diagnostic Tool to Differentiate Phyllodes Tumor From Fibroadenoma Arch Surg, September 1, 2003; 138(9): 987 - 990. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Pfarl, T. H. Helbich, C. C. Riedl, T. Wagner, M. Gnant, M. Rudas, and L. Liberman Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study Am. J. Roentgenol., December 1, 2002; 179(6): 1503 - 1507. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Brenner, R. J. Jackman, S. H. Parker, W. P. Evans III, L. Philpotts, B. M. Deutch, M. C. Lechner, D. Lehrer, P. Sylvan, R. Hunt, et al. Percutaneous Core Needle Biopsy of Radial Scars of the Breast: When Is Excision Necessary? Am. J. Roentgenol., November 1, 2002; 179(5): 1179 - 1184. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Jackman, R. L. Birdwell, and D. M. Ikeda Atypical Ductal Hyperplasia: Can Some Lesions Be Defined as Probably Benign after Stereotactic 11-gauge Vacuum-assisted Biopsy, Eliminating the Recommendation for Surgical Excision? Radiology, August 1, 2002; 224(2): 548 - 554. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Wunderbaldinger, G. Wolf, K. Turetschek, and T. H. Helbich Comparison of Sitting Versus Prone Position for Stereotactic Large-Core Breast Biopsy in Surgically Proven Lesions Am. J. Roentgenol., May 1, 2002; 178(5): 1221 - 1225. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Margolin, J. W. T. Leung, R. P. Jacobs, and S. R. Denny Percutaneous Imaging-Guided Core Breast Biopsy: 5 Years' Experience in a Community Hospital Am. J. Roentgenol., September 1, 2001; 177(3): 559 - 564. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. K. Kuhl, N. Morakkabati, C. C. Leutner, A. Schmiedel, E. Wardelmann, and H. H. Schild MR Imaging-guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging Alone Radiology, July 1, 2001; 220(1): 31 - 39. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, C. L. Benton, D. D. Dershaw, A. F. Abramson, L. R. LaTrenta, and E. A. Morris Learning Curve for Stereotactic Breast Biopsy: How Many Cases Are Enough? Am. J. Roentgenol., March 1, 2001; 176(3): 721 - 727. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Jackman, F. Burbank, S. H. Parker, W. P. Evans III, M. C. Lechner, T. R. Richardson, A. A. Smid, H. B. Borofsky, C. H. Lee, H. M. Goldstein, et al. Stereotactic Breast Biopsy of Nonpalpable Lesions: Determinants of Ductal Carcinoma in Situ Underestimation Rates Radiology, February 1, 2001; 218(2): 497 - 502. [Abstract] [Full Text] |
||||
![]() |
L. Liberman, L. A. Ernberg, A. Heerdt, M. F. Zakowski, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and D. D. Dershaw Palpable Breast Masses: Is There a Role for Percutaneous Imaging-Guided Core Biopsy? Am. J. Roentgenol., September 1, 2000; 175(3): 779 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. E. Burak Jr, K. E. Owens, M. B. Tighe, L. Kemp, S. A. Dinges, C. L. Hitchcock, and J. Olsen Vacuum-Assisted Stereotactic Breast Biopsy: Histologic Underestimation of Malignant Lesions Arch Surg, June 1, 2000; 135(6): 700 - 703. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
H. E. Reynolds Core Needle Biopsy of Challenging Benign Breast Conditions: A Comprehensive Literature Review Am. J. Roentgenol., May 1, 2000; 174(5): 1245 - 1250. [Full Text] [PDF] |
||||
![]() |
J. E. Meyer, D. N. Smith, S. C. Lester, C. Kaelin, P. J. DiPiro, C. M. Denison, R. L. Christian, S. C. Harvey, D.-L. G. Selland, and S. M. Durfee Large-Core Needle Biopsy of Nonpalpable Breast Lesions JAMA, May 5, 1999; 281(17): 1638 - 1641. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Harvey, C. M. Denison, S. C. Lester, P. J. DiPiro, D. N. Smith, and J. E. Meyer Fibrous Nodules Found at Large-Core Needle Biopsy of the Breast: Imaging Features Radiology, May 1, 1999; 211(2): 535 - 540. [Abstract] [Full Text] |
||||
![]() |
R. J. Jackman, K. W. Nowels, J. Rodriguez-Soto, F. A. Marzoni Jr, S. I. Finkelstein, and M. J. Shepard Stereotactic, Automated, Large-Core Needle Biopsy of Nonpalpable Breast Lesions: False-Negative and Histologic Underestimation Rates after Long-term Follow-up Radiology, March 1, 1999; 210(3): 799 - 805. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |