Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyer, J. E.
Right arrow Articles by Ko, W. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyer, J. E.
Right arrow Articles by Ko, W. D.

Radiology, Vol 206, 717-720, Copyright © 1998 by Radiological Society of North America


ARTICLES

Large-needle core biopsy: nonmalignant breast abnormalities evaluated with surgical excision or repeat core biopsy

JE Meyer, DN Smith, SC Lester, PJ DiPiro, CM Denison, SC Harvey, RL Christian, A Richardson and WD Ko
Department of Radiology, Brigham and Women's Hospital, Boston, MA 02115, USA.

PURPOSE: To classify lesions initially considered nonmalignant at large- needle core biopsy that were subsequently surgically excised or sampled at repeat biopsy. MATERIALS AND METHODS: From August 1, 1991, to December 31, 1996, 1,032 breast abnormalities (214 malignant and 818 nonmalignant lesions) were sampled at large-needle core biopsy. Of the nonmalignant lesions, 112 (14%) abnormalities were studied. Twenty-four abnormalities were subsequently excised because of discordant imaging and pathologic findings; 41 may have been missed at biopsy (25 were surgically excised, and 16 were sampled at repeat biopsy); 40 were surgically excised as recommended by the pathologist; and seven were excised for other indications. RESULTS: None of 24 abnormalities excised because of discordant findings was malignant. Among the 41 possibly missed lesions, infiltrating ductal carcinoma was found in one lesion that was removed surgically and in one sampled at repeat biopsy. Among the 40 lesions recommended for excision by the pathologist, 16 malignancies were found (ductal carcinoma in situ, 11; infiltrating ductal carcinoma, three; phyllodes tumor, two). None of the remaining seven lesions was malignant. CONCLUSION: Correlation of the technical quality of the biopsy, imaging features, and pathologic findings resulted in 96 surgical excisions and 16 repeat biopsies of lesions initially considered nonmalignant. Eighteen additional malignancies were identified.


This article has been cited by other articles:


Home page
RadiologyHome page
G. Schueller, S. Jaromi, L. Ponhold, M. Fuchsjaeger, M. Memarsadeghi, M. Rudas, M. Weber, L. Liberman, and T. H. Helbich
US-guided 14-gauge Core-Needle Breast Biopsy: Results of a Validation Study in 1352 Cases
Radiology, August 1, 2008; 248(2): 406 - 413.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J.-M. Lee, J. B. Kaplan, M. P. Murray, L. Bartella, E. A. Morris, S. Joo, D. D. Dershaw, and L. Liberman
Imaging Histologic Discordance at MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy
Am. J. Roentgenol., October 1, 2007; 189(4): 852 - 859.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
M. F. Dillon, E. W. McDermott, A. D. Hill, A. O'Doherty, N. O'Higgins, and C. M. Quinn
Predictive Value of Breast Lesions of "Uncertain Malignant Potential" and "Suspicious for Malignancy" Determined by Needle Core Biopsy
Ann. Surg. Oncol., February 1, 2007; 14(2): 704 - 711.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen
Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis?
Radiology, September 1, 2005; 236(3): 801 - 809.
[Abstract] [Full Text] [PDF]


Home page
Arch SurgHome page
I. K. Komenaka, M. El-Tamer, E. Pile-Spellman, and H. Hibshoosh
Core Needle Biopsy as a Diagnostic Tool to Differentiate Phyllodes Tumor From Fibroadenoma
Arch Surg, September 1, 2003; 138(9): 987 - 990.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Pfarl, T. H. Helbich, C. C. Riedl, T. Wagner, M. Gnant, M. Rudas, and L. Liberman
Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study
Am. J. Roentgenol., December 1, 2002; 179(6): 1503 - 1507.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. J. Brenner, R. J. Jackman, S. H. Parker, W. P. Evans III, L. Philpotts, B. M. Deutch, M. C. Lechner, D. Lehrer, P. Sylvan, R. Hunt, et al.
Percutaneous Core Needle Biopsy of Radial Scars of the Breast: When Is Excision Necessary?
Am. J. Roentgenol., November 1, 2002; 179(5): 1179 - 1184.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman, R. L. Birdwell, and D. M. Ikeda
Atypical Ductal Hyperplasia: Can Some Lesions Be Defined as Probably Benign after Stereotactic 11-gauge Vacuum-assisted Biopsy, Eliminating the Recommendation for Surgical Excision?
Radiology, August 1, 2002; 224(2): 548 - 554.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Wunderbaldinger, G. Wolf, K. Turetschek, and T. H. Helbich
Comparison of Sitting Versus Prone Position for Stereotactic Large-Core Breast Biopsy in Surgically Proven Lesions
Am. J. Roentgenol., May 1, 2002; 178(5): 1221 - 1225.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. R. Margolin, J. W. T. Leung, R. P. Jacobs, and S. R. Denny
Percutaneous Imaging-Guided Core Breast Biopsy: 5 Years' Experience in a Community Hospital
Am. J. Roentgenol., September 1, 2001; 177(3): 559 - 564.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, N. Morakkabati, C. C. Leutner, A. Schmiedel, E. Wardelmann, and H. H. Schild
MR Imaging-guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging Alone
Radiology, July 1, 2001; 220(1): 31 - 39.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, C. L. Benton, D. D. Dershaw, A. F. Abramson, L. R. LaTrenta, and E. A. Morris
Learning Curve for Stereotactic Breast Biopsy: How Many Cases Are Enough?
Am. J. Roentgenol., March 1, 2001; 176(3): 721 - 727.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman, F. Burbank, S. H. Parker, W. P. Evans III, M. C. Lechner, T. R. Richardson, A. A. Smid, H. B. Borofsky, C. H. Lee, H. M. Goldstein, et al.
Stereotactic Breast Biopsy of Nonpalpable Lesions: Determinants of Ductal Carcinoma in Situ Underestimation Rates
Radiology, February 1, 2001; 218(2): 497 - 502.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
L. Liberman, L. A. Ernberg, A. Heerdt, M. F. Zakowski, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and D. D. Dershaw
Palpable Breast Masses: Is There a Role for Percutaneous Imaging-Guided Core Biopsy?
Am. J. Roentgenol., September 1, 2000; 175(3): 779 - 787.
[Abstract] [Full Text] [PDF]


Home page
Arch SurgHome page
W. E. Burak Jr, K. E. Owens, M. B. Tighe, L. Kemp, S. A. Dinges, C. L. Hitchcock, and J. Olsen
Vacuum-Assisted Stereotactic Breast Biopsy: Histologic Underestimation of Malignant Lesions
Arch Surg, June 1, 2000; 135(6): 700 - 703.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman
Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium
Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. E. Reynolds
Core Needle Biopsy of Challenging Benign Breast Conditions: A Comprehensive Literature Review
Am. J. Roentgenol., May 1, 2000; 174(5): 1245 - 1250.
[Full Text] [PDF]


Home page
JAMAHome page
J. E. Meyer, D. N. Smith, S. C. Lester, C. Kaelin, P. J. DiPiro, C. M. Denison, R. L. Christian, S. C. Harvey, D.-L. G. Selland, and S. M. Durfee
Large-Core Needle Biopsy of Nonpalpable Breast Lesions
JAMA, May 5, 1999; 281(17): 1638 - 1641.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. C. Harvey, C. M. Denison, S. C. Lester, P. J. DiPiro, D. N. Smith, and J. E. Meyer
Fibrous Nodules Found at Large-Core Needle Biopsy of the Breast: Imaging Features
Radiology, May 1, 1999; 211(2): 535 - 540.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. J. Jackman, K. W. Nowels, J. Rodriguez-Soto, F. A. Marzoni Jr, S. I. Finkelstein, and M. J. Shepard
Stereotactic, Automated, Large-Core Needle Biopsy of Nonpalpable Breast Lesions: False-Negative and Histologic Underestimation Rates after Long-term Follow-up
Radiology, March 1, 1999; 210(3): 799 - 805.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.