Radiology, Vol 206, 791-798, Copyright © 1998 by Radiological Society of North America
ARTICLES |
ER Niendorf, TM Grist, FT Lee Jr, PC Brazy and GE Santyr
Department of Medical Physics, University of Wisconsin-Madison 53792, USA.
PURPOSE: To compare the accuracy of a noninvasive magnetic resonance (MR) imaging method to rapidly determine single-kidney glomerular filtration rate (GFR) relative to findings with an accepted standard of reference. MATERIALS AND METHODS: Simultaneous inulin and MR imaging measurements of renal excretory function were performed in six small swine. Renal extraction fraction of gadopentetate dimeglumine was determined with T1 measurements of flowing blood in the renal vein and in a systemic vessel 10-300 minutes after administration. These data were correlated with standard inulin-derived measurements of single- kidney GFR obtained during the same intervals as the MR imaging measurements. Gradient-echo (GRE) and echo-planar imaging were investigated for in vivo measurement of extraction fraction. RESULTS: The MR imaging-derived measurements of extraction fraction and single- kidney GFR were not significantly different from the inulin-determined measures (P > .18). The MR imaging extraction fraction and single- kidney GFR measurements correlated with inulin-derived measurements of the same parameters (r = .74 to .89, P < .0007). CONCLUSION: T1 measurement methods with GRE and echo-planar imaging are acceptable techniques with which to measure renal excretory function in a rapid and noninvasive manner in this model. Rapid measurements of single- kidney GFR should enable studies of the response of renal hemodynamics to pharmaceutical manipulation.
This article has been cited by other articles:
![]() |
P.-H. Vivier, M. Dolores, I. Gardin, P. Zhang, C. Petitjean, and J.-N. Dacher In Vitro Assessment of a 3D Segmentation Algorithm Based on the Belief Functions Theory in Calculating Renal Volumes by MRI Am. J. Roentgenol., September 1, 2008; 191(3): W127 - W134. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. R. Martin, P. Sharma, K. Salman, R. A. Jones, J. D. Grattan-Smith, H. Mao, T. C. Lauenstein, B. K. Burrow, D. L. Tudorascu, and J. R. Votaw Individual Kidney Blood Flow Measured with Contrast-enhanced First-Pass Perfusion MR Imaging Radiology, January 1, 2008; 246(1): 241 - 248. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Park, T. K. Rhee, T. A. Cashen, W. Shin, B. E. Schirf, J. A. Gehl, A. C. Larson, P. V. Prasad, D. Li, T. J. Carroll, et al. Renal Artery Stenosis in Swine: Feasibility of MR Assessment of Renal Function during Percutaneous Transluminal Angioplasty Radiology, July 1, 2007; 244(1): 144 - 150. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, H. Rusinek, L. Bokacheva, A. J. Huang, N. Oesingmann, Q. Chen, M. Kaur, K. Prince, T. Song, E. L. Kramer, et al. Renal function measurements from MR renography and a simplified multicompartmental model Am J Physiol Renal Physiol, May 1, 2007; 292(5): F1548 - F1559. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. V. Prasad Functional MRI of the kidney: tools for translational studies of pathophysiology of renal disease Am J Physiol Renal Physiol, May 1, 2006; 290(5): F958 - F974. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Jones, K. Easley, S. B. Little, H. Scherz, A. J. Kirsch, and J. D. Grattan-Smith Dynamic Contrast-Enhanced MR Urography in the Evaluation of Pediatric Hydronephrosis: Part 1, Functional Assessment Am. J. Roentgenol., December 1, 2005; 185(6): 1598 - 1607. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Sommer, E. W. Olcott, L. C. Chow, R. R. Saket, and P. Schraedley-Desmond Measurement of Renal Extraction Fraction with Contrast-enhanced CT Radiology, September 1, 2005; 236(3): 1029 - 1033. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Mizzi and J Moss Renovascular hypertension Imaging, August 1, 2005; 17(1): 44 - 52. [Full Text] [PDF] |
||||
![]() |
H. S. Teh, E. S. Ang, W. C. Wong, S. B. Tan, A. G. S. Tan, S. M. Chng, M. B. K. Lin, and J. S. K. Goh MR Renography Using a Dynamic Gradient-Echo Sequence and Low-Dose Gadopentetate Dimeglumine as an Alternative to Radionuclide Renography Am. J. Roentgenol., August 1, 2003; 181(2): 441 - 450. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, H. Rusinek, M. E. Noz, P. Lee, M. Raghavan, and E. L. Kramer Dynamic Three-dimensional MR Renography for the Measurement of Single Kidney Function: Initial Experience Radiology, April 1, 2003; 227(1): 289 - 294. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. H. Coulam, J. H. Lee, K. L. Wedding, D. M. Spielman, N. J. Pelc, S. T. Kee, B. B. Hill, D. M. Bouley, G. C. Derby, B. D. Myers, et al. Noninvasive Measurement of Extraction Fraction and Single-Kidney Glomerular Filtration Rate with MR Imaging in Swine with Surgically Created Renal Arterial Stenoses Radiology, April 1, 2002; 223(1): 76 - 82. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. O. Schoenberg, M. V. Knopp, F. Londy, S. Krishnan, I. Zuna, N. Lang, M. Essig, H. Hawighorst, J. H. Maki, D. Stafford-Johnson, et al. Morphologic and Functional Magnetic Resonance Imaging of Renal Artery Stenosis: A Multireader Tricenter Study J. Am. Soc. Nephrol., January 1, 2002; 13(1): 158 - 169. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Omary, K. P. Henseler, O. Unal, L. J. Maciolek, J. P. Finn, D. Li, A. A. Nemcek Jr., R. L. Vogelzang, and T. M. Grist Comparison of Intraarterial and IV Gadolinium-Enhanced MR Angiography with Digital Subtraction Angiography for the Detection of Renal Artery Stenosis in Pigs Am. J. Roentgenol., January 1, 2002; 178(1): 119 - 123. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Krier, E. L. Ritman, Z. Bajzer, J. C. Romero, A. Lerman, and L. O. Lerman Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function Am J Physiol Renal Physiol, October 1, 2001; 281(4): F630 - F638. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. O. Lerman and M. Rodriguez-Porcel Functional Assessment of the Circulation of the Single Kidney Hypertension, September 1, 2001; 38(3): 625 - 629. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. O. SCHOENBERG, M. BOCK, F. KALLINOWSKI, and A. JUST Correlation of Hemodynamic Impact and Morphologic Degree of Renal Artery Stenosis in a Canine Model J. Am. Soc. Nephrol., December 1, 2000; 11(12): 2190 - 2198. [Abstract] [Full Text] |
||||
![]() |
Q. Dong, S. O. Schoenberg, R. C. Carlos, M. Neimatallah, K. J. Cho, D. M. Williams, S. N. Kazanjian, and M. R. Prince Diagnosis of Renal Vascular Disease with MR Angiography RadioGraphics, November 1, 1999; 19(6): 1535 - 1554. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Katzberg, T. M. Grist, E. R. Niendorf, F. T. Lee Jr, P. C. Brazy, and G. R. Santyr Noninvasive Measurement of Renal Hemodynamic Functions with Gadolinium-enhanced MR Imaging • Dr Grist and colleagues respond: Radiology, January 1, 1999; 210(1): 287 - 288. [Full Text] |
||||
![]() |
V. S. Lee, H. Rusinek, G. Johnson, N. M. Rofsky, G. A. Krinsky, and J. C. Weinreb MR Renography with Low-Dose Gadopentetate Dimeglumine: Feasibility Radiology, November 1, 2001; 221(2): 371 - 379. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |