|
|
||||||||
Radiology, Vol 207, 331-337, Copyright © 1998 by Radiological Society of North America
ARTICLES |
Y Yamashita, Y Tang, T Namimoto, K Mitsuzaki and M Takahashi
Department of Radiology, Kumamoto University School of Medicine, Japan.
PURPOSE: To evaluate single-shot T2-weighted magnetic resonance sequences and their role in clinical practice in patients with hepatic lesions. MATERIALS AND METHODS: Prospective comparison of echo-planar and half-Fourier rapid acquisition with relaxation enhancement (RARE) imaging was performed in 80 patients with focal hepatic lesions. Spin- echo (SE) single-shot echo-planar (echo times, 47 and 80 msec) and half- Fourier RARE (echo time, 59 msec) images were compared with turbo SE (repetition time msec/echo time msec = 3,200-7,600/90) images. Quantitative, qualitative, and receiver operating characteristic (ROC) analyses were performed. RESULTS: For liver, signal-to-noise ratios on half-Fourier RARE images were significantly higher than those on echo- planar images (P < .01). For cystic lesions, contrast on half-Fourier RARE and echo-planar images was slightly higher than that on turbo SE images. For solid lesions, contrast on echo-planar images was better than that on half-Fourier RARE or turbo SE images. Artifacts including ghosting, bowel motion, susceptibility difference, and chemical shift were negligible on half-Fourier RARE images in all patients, whereas susceptibility difference and chemical shift of various degrees were seen on all echo-planar images. On the basis of ROC analyses, tumor detection rates were significantly higher with half-Fourier RARE and turbo SE images than with echo-planar images (P < .01). CONCLUSION: Echo-planar images provide sufficient contrast to allow detection of both solid and cystic masses, but severe artifacts preclude routine use. Half-Fourier RARE images are free from artifacts (chemical shift and susceptibility) and diagnostic performance with them is similar to that with turbo SE images.
This article has been cited by other articles:
![]() |
Y. K. Kim, C. S. Kim, G. H. Chung, S. B. Jeon, and J. M. Lee Feasibility of Application of Sensitivity Encoding to the Breath-Hold T2-Weighted Turbo Spin-Echo Sequence for Evaluation of Focal Hepatic Tumors Am. J. Roentgenol., February 1, 2005; 184(2): 497 - 504. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Dromain, T. de Baere, E. Baudin, J. Galline, M. Ducreux, V. Boige, P. Duvillard, A. Laplanche, H. Caillet, P. Lasser, et al. MR Imaging of Hepatic Metastases Caused by Neuroendocrine Tumors: Comparing Four Techniques Am. J. Roentgenol., January 1, 2003; 180(1): 121 - 128. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Masui, M. Katayama, S. Kobayashi, S. Nakayama, A. Nozaki, H. Kabasawa, T. Ito, and H. Sakahara Changes in Myometrial and Junctional Zone Thickness and Signal Intensity: Demonstration with Kinematic T2-weighted MR Imaging Radiology, October 1, 2001; 221(1): 75 - 85. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Terkivatan, J. H. W. de Wilt, R. A. de Man, R. R. van Rijn, P. E. Zondervan, H. W. Tilanus, and J. N. M. IJzermans Indications and Long-term Outcome of Treatment for Benign Hepatic Tumors: A Critical Appraisal Arch Surg, September 1, 2001; 136(9): 1033 - 1038. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hori, T. Murakami, T. Kim, M. Kanematsu, K. Tsuda, S. Takahashi, M. Takamura, H. Hoshi, and H. Nakamura Single Breath-Hold T2-Weighted MR Imaging of the Liver: Value of Single-Shot Fast Spin-Echo and Multishot Spin-Echo Echoplanar Imaging Am. J. Roentgenol., May 1, 2000; 174(5): 1423 - 1431. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. T. Sica, H. Ji, and P. R. Ros CT and MR Imaging of Hepatic Metastases Am. J. Roentgenol., March 1, 2000; 174(3): 691 - 698. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |