Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Albrecht, T.
Right arrow Articles by Schlief, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Albrecht, T.
Right arrow Articles by Schlief, R.

Radiology, Vol 207, 339-347, Copyright © 1998 by Radiological Society of North America


ARTICLES

Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion: preliminary experience

T Albrecht, A Urbank, M Mahler, A Bauer, CJ Dore, MJ Blomley, DO Cosgrove and R Schlief
Department of Imaging, Hammersmith Hospital, Imperial College, School of Medicine, London, England.

PURPOSE: To investigate whether continuous infusion of an echo- enhancing contrast agent for up to 15 minutes can provide uniform and prolonged enhancement. MATERIALS AND METHODS: Six volunteers each received one bolus and three infusions of a microbubble contrast agent over 6-15 minutes at (a) a standard rate (mean, 2.08 mL/min), (b) a fast rate at twice the standard rate, and (c) a slow rate at half the standard rate. Spectral Doppler intensitometry of the femoral artery was performed for all infusions. Spectral Doppler ultrasound (US) scans of the femoral artery and color Doppler US scans of the carotid artery were subjectively assessed. RESULTS: All infusions provided an equilibrium plateau of constant prolonged enhancement starting after 1- 2 minutes and lasting until the end of the infusion. Enhancement at the plateau was +13 dB (slow rate), +17.1 dB (standard rate), and +18.3 dB (fast rate) compared with baseline. Saturation artifacts with infusions were markedly fewer than those with bolus injections. Dose effectiveness (duration of enhancement that measured at least 7.5 dB per gram of contrast agent) was markedly improved with the infusions, from 0.8 min/g for the bolus to 2.6 min/g for the slow infusion. CONCLUSION: Continuous infusion of the microbubble contrast agent provided prolonged and uniform enhancement of Doppler signals and improved image quality by minimizing saturation artifacts.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
T. Holscher, J.A. Sattin, R. Raman, W. Wilkening, C.V. Fanale, S.E. Olson, R.F. Mattrey, and P.D. Lyden
Real-Time Cerebral Angiography: Sensitivity of a New Contrast-Specific Ultrasound Technique
AJNR Am. J. Neuroradiol., April 1, 2007; 28(4): 635 - 639.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. Quaia, A. Palumbo, S. Rossi, F. Degobbis, S. Cernic, G. Tona, and M. Cova
Comparison of visual and quantitative analysis for characterization of insonated liver tumors after microbubble contrast injection.
Am. J. Roentgenol., June 1, 2006; 186(6): 1560 - 1570.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P S Sidhu, P L Allan, F Cattin, D O Cosgrove, A H Davies, D D Do, S Karakagil, J Langholz, D A Legemate, A Martegani, et al.
Diagnostic efficacy of SonoVue(R), a second generation contrast agent, in the assessment of extracranial carotid or peripheral arteries using colour and spectral Doppler ultrasound: a multicentre study
Br. J. Radiol., January 1, 2006; 79(937): 44 - 51.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Okada, C. W. Hoffmann, K. J. Wolf, and T. Albrecht
Bolus versus Continuous Infusion of Microbubble Contrast Agent for Liver US: Initial Experience
Radiology, December 1, 2005; 237(3): 1063 - 1067.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
H Maruyama, S Matsutani, H Saisho, Y Mine, N Kamiyama, T Hirata, and M Sasamata
Real-time blood-pool images of contrast enhanced ultrasound with Definity in the detection of tumour nodules in the liver
Br. J. Radiol., June 1, 2005; 78(930): 512 - 518.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D Cosgrove
Angiogenesis imaging - ultrasound
Br. J. Radiol., December 1, 2003; 76(suppl_1): S43 - S49.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
H. Maruyama, S. Matsutani, H. Saisho, Y. Mine, H. Yuki, and K. Miyata
Extra-Low Acoustic Power Harmonic Images of the Liver With Perflutren: Novel Imaging for Real-Time Observation of Liver Perfusion
J. Ultrasound Med., September 1, 2003; 22(9): 931 - 938.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M.-R. Orden, J. S. Jurvelin, and P. P. Kirkinen
Kinetics of a US Contrast Agent in Benign and Malignant Adnexal Tumors
Radiology, February 1, 2003; 226(2): 405 - 410.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. Lassau, S. Koscielny, M.-F. Avril, A. Margulis, P. Duvillard, T. de Baere, A. Roche, and J. Leclere
Prognostic Value of Angiogenesis Evaluated with High-Frequency and Color Doppler Sonography for Preoperative Assessment of Melanomas
Am. J. Roentgenol., June 1, 2002; 178(6): 1547 - 1551.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
L. Agati, S. Funaro, M. Madonna, C. Volponi, G. Veneroso, and G. Tonti
Clinical utility of contrast echocardiography in the management of patients with acute myocardial infarction
Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C27 - C34.
[Abstract] [PDF]


Home page
Eur Heart J SupplHome page
G. Deklunder
Role of ultrasound and contrast-enhanced ultrasound in patients with cerebrovascular disease
Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C51 - C55.
[Abstract] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Schiedermaier, G. Layer, and T. Sauerbruch
Impact of the Continuous Infusion of Levovist on Color Doppler Sonography in Portal Hypertension
Am. J. Roentgenol., January 1, 2002; 178(1): 61 - 65.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Kuntz-Hehner, J. Goenechea, C. Pohl, T. Schlosser, C. Veltmann, C. Lentz, S. Lohmaier, A. Ehlgen, H. Omran, H. Becher, et al.
Continuous-Infusion Contrast-enhanced US: In Vitro Studies of Infusion Techniques with Different Contrast Agents
Radiology, September 1, 2001; 220(3): 647 - 654.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. F. Meloni, S. N. Goldberg, T. Livraghi, F. Calliada, P. Ricci, M. Rossi, D. Pallavicini, and R. Campani
Hepatocellular Carcinoma Treated with Radiofrequency Ablation: Comparison of Pulse Inversion Contrast-Enhanced Harmonic Sonography, Contrast-Enhanced Power Doppler Sonography, and Helical CT
Am. J. Roentgenol., August 1, 2001; 177(2): 375 - 380.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Holscher, F. Schlachetzki, A. Bauer, L. Rosin, B. Gotz, and U. Bogdahn
Echo-enhanced Transcranial Color-coded US: Clinical Usefulness of Intravenous Infusion versus Bolus Injection of SH U 508A
Radiology, June 1, 2001; 219(3): 823 - 827.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
M. Rohrberg and R. Brodhun
Measurement of Vasomotor Reserve in the Transcranial Doppler-CO2 Test Using an Ultrasound Contrast Agent (Levovist)
Stroke, June 1, 2001; 32(6): 1298 - 1303.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
M. J K Blomley, J. C Cooke, E. C Unger, M. J Monaghan, and D. O Cosgrove
Science, medicine, and the future: Microbubble contrast agents: a new era in ultrasound
BMJ, May 19, 2001; 322(7296): 1222 - 1225.
[Full Text]


Home page
StrokeHome page
R. A. Boyajian, S. M. Otis, D.W. Droste, R. Jurgens, R. Tietje, E.B. Ringelstein, and S. Weber
Continuous Infusion Versus Bolus Injection Of Ultrasound Contrast Agents in Vascular Doppler Flow Imaging Response
Stroke, September 1, 2000; 31 (9): 2266 - 2278.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
H. G. Khan, P. Gailloud, R. O. Bude, J.-B. Martin, K. T. Szopinski, C. Khaw, D. A. Rüfenacht, and K. J. Murphy
The Effect of Contrast Material on Transcranial Doppler Evaluation of Normal Middle Cerebral Artery Peak Systolic Velocity
AJNR Am. J. Neuroradiol., February 1, 2000; 21(2): 386 - 390.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. N. Goldberg, R. C. Walovitch, J. A. Straub, M. T. Shore, and G. S. Gazelle
Radio-frequency-induced Coagulation Necrosis in Rabbits: Immediate Detection at US with a Synthetic Microsphere Contrast Agent
Radiology, November 1, 1999; 213(2): 438 - 444.
[Abstract] [Full Text]


Home page
RadiologyHome page
F. Frauscher, G. Janetschek, G. Helweg, H. Strasser, G. Bartsch, and D. z. Nedden
Crossing Vessels at the Ureteropelvic Junction: Detection with Contrast-enhanced Color Doppler Imaging
Radiology, March 1, 1999; 210(3): 727 - 731.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.