Radiology, Vol 207, 339-347, Copyright © 1998 by Radiological Society of North America
ARTICLES |
T Albrecht, A Urbank, M Mahler, A Bauer, CJ Dore, MJ Blomley, DO Cosgrove and R Schlief
Department of Imaging, Hammersmith Hospital, Imperial College, School of Medicine, London, England.
PURPOSE: To investigate whether continuous infusion of an echo- enhancing contrast agent for up to 15 minutes can provide uniform and prolonged enhancement. MATERIALS AND METHODS: Six volunteers each received one bolus and three infusions of a microbubble contrast agent over 6-15 minutes at (a) a standard rate (mean, 2.08 mL/min), (b) a fast rate at twice the standard rate, and (c) a slow rate at half the standard rate. Spectral Doppler intensitometry of the femoral artery was performed for all infusions. Spectral Doppler ultrasound (US) scans of the femoral artery and color Doppler US scans of the carotid artery were subjectively assessed. RESULTS: All infusions provided an equilibrium plateau of constant prolonged enhancement starting after 1- 2 minutes and lasting until the end of the infusion. Enhancement at the plateau was +13 dB (slow rate), +17.1 dB (standard rate), and +18.3 dB (fast rate) compared with baseline. Saturation artifacts with infusions were markedly fewer than those with bolus injections. Dose effectiveness (duration of enhancement that measured at least 7.5 dB per gram of contrast agent) was markedly improved with the infusions, from 0.8 min/g for the bolus to 2.6 min/g for the slow infusion. CONCLUSION: Continuous infusion of the microbubble contrast agent provided prolonged and uniform enhancement of Doppler signals and improved image quality by minimizing saturation artifacts.
This article has been cited by other articles:
![]() |
T. Holscher, J.A. Sattin, R. Raman, W. Wilkening, C.V. Fanale, S.E. Olson, R.F. Mattrey, and P.D. Lyden Real-Time Cerebral Angiography: Sensitivity of a New Contrast-Specific Ultrasound Technique AJNR Am. J. Neuroradiol., April 1, 2007; 28(4): 635 - 639. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Quaia, A. Palumbo, S. Rossi, F. Degobbis, S. Cernic, G. Tona, and M. Cova Comparison of visual and quantitative analysis for characterization of insonated liver tumors after microbubble contrast injection. Am. J. Roentgenol., June 1, 2006; 186(6): 1560 - 1570. [Abstract] [Full Text] [PDF] |
||||
![]() |
P S Sidhu, P L Allan, F Cattin, D O Cosgrove, A H Davies, D D Do, S Karakagil, J Langholz, D A Legemate, A Martegani, et al. Diagnostic efficacy of SonoVue(R), a second generation contrast agent, in the assessment of extracranial carotid or peripheral arteries using colour and spectral Doppler ultrasound: a multicentre study Br. J. Radiol., January 1, 2006; 79(937): 44 - 51. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Okada, C. W. Hoffmann, K. J. Wolf, and T. Albrecht Bolus versus Continuous Infusion of Microbubble Contrast Agent for Liver US: Initial Experience Radiology, December 1, 2005; 237(3): 1063 - 1067. [Abstract] [Full Text] [PDF] |
||||
![]() |
H Maruyama, S Matsutani, H Saisho, Y Mine, N Kamiyama, T Hirata, and M Sasamata Real-time blood-pool images of contrast enhanced ultrasound with Definity in the detection of tumour nodules in the liver Br. J. Radiol., June 1, 2005; 78(930): 512 - 518. [Abstract] [Full Text] [PDF] |
||||
![]() |
D Cosgrove Angiogenesis imaging - ultrasound Br. J. Radiol., December 1, 2003; 76(suppl_1): S43 - S49. [Full Text] [PDF] |
||||
![]() |
H. Maruyama, S. Matsutani, H. Saisho, Y. Mine, H. Yuki, and K. Miyata Extra-Low Acoustic Power Harmonic Images of the Liver With Perflutren: Novel Imaging for Real-Time Observation of Liver Perfusion J. Ultrasound Med., September 1, 2003; 22(9): 931 - 938. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-R. Orden, J. S. Jurvelin, and P. P. Kirkinen Kinetics of a US Contrast Agent in Benign and Malignant Adnexal Tumors Radiology, February 1, 2003; 226(2): 405 - 410. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Lassau, S. Koscielny, M.-F. Avril, A. Margulis, P. Duvillard, T. de Baere, A. Roche, and J. Leclere Prognostic Value of Angiogenesis Evaluated with High-Frequency and Color Doppler Sonography for Preoperative Assessment of Melanomas Am. J. Roentgenol., June 1, 2002; 178(6): 1547 - 1551. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Agati, S. Funaro, M. Madonna, C. Volponi, G. Veneroso, and G. Tonti Clinical utility of contrast echocardiography in the management of patients with acute myocardial infarction Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C27 - C34. [Abstract] [PDF] |
||||
![]() |
G. Deklunder Role of ultrasound and contrast-enhanced ultrasound in patients with cerebrovascular disease Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C51 - C55. [Abstract] [PDF] |
||||
![]() |
P. Schiedermaier, G. Layer, and T. Sauerbruch Impact of the Continuous Infusion of Levovist on Color Doppler Sonography in Portal Hypertension Am. J. Roentgenol., January 1, 2002; 178(1): 61 - 65. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kuntz-Hehner, J. Goenechea, C. Pohl, T. Schlosser, C. Veltmann, C. Lentz, S. Lohmaier, A. Ehlgen, H. Omran, H. Becher, et al. Continuous-Infusion Contrast-enhanced US: In Vitro Studies of Infusion Techniques with Different Contrast Agents Radiology, September 1, 2001; 220(3): 647 - 654. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. F. Meloni, S. N. Goldberg, T. Livraghi, F. Calliada, P. Ricci, M. Rossi, D. Pallavicini, and R. Campani Hepatocellular Carcinoma Treated with Radiofrequency Ablation: Comparison of Pulse Inversion Contrast-Enhanced Harmonic Sonography, Contrast-Enhanced Power Doppler Sonography, and Helical CT Am. J. Roentgenol., August 1, 2001; 177(2): 375 - 380. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Holscher, F. Schlachetzki, A. Bauer, L. Rosin, B. Gotz, and U. Bogdahn Echo-enhanced Transcranial Color-coded US: Clinical Usefulness of Intravenous Infusion versus Bolus Injection of SH U 508A Radiology, June 1, 2001; 219(3): 823 - 827. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Rohrberg and R. Brodhun Measurement of Vasomotor Reserve in the Transcranial Doppler-CO2 Test Using an Ultrasound Contrast Agent (Levovist) Stroke, June 1, 2001; 32(6): 1298 - 1303. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J K Blomley, J. C Cooke, E. C Unger, M. J Monaghan, and D. O Cosgrove Science, medicine, and the future: Microbubble contrast agents: a new era in ultrasound BMJ, May 19, 2001; 322(7296): 1222 - 1225. [Full Text] |
||||
![]() |
R. A. Boyajian, S. M. Otis, D.W. Droste, R. Jurgens, R. Tietje, E.B. Ringelstein, and S. Weber Continuous Infusion Versus Bolus Injection Of Ultrasound Contrast Agents in Vascular Doppler Flow Imaging Response Stroke, September 1, 2000; 31 (9): 2266 - 2278. [Full Text] [PDF] |
||||
![]() |
H. G. Khan, P. Gailloud, R. O. Bude, J.-B. Martin, K. T. Szopinski, C. Khaw, D. A. Rüfenacht, and K. J. Murphy The Effect of Contrast Material on Transcranial Doppler Evaluation of Normal Middle Cerebral Artery Peak Systolic Velocity AJNR Am. J. Neuroradiol., February 1, 2000; 21(2): 386 - 390. [Abstract] [Full Text] |
||||
![]() |
S. N. Goldberg, R. C. Walovitch, J. A. Straub, M. T. Shore, and G. S. Gazelle Radio-frequency-induced Coagulation Necrosis in Rabbits: Immediate Detection at US with a Synthetic Microsphere Contrast Agent Radiology, November 1, 1999; 213(2): 438 - 444. [Abstract] [Full Text] |
||||
![]() |
F. Frauscher, G. Janetschek, G. Helweg, H. Strasser, G. Bartsch, and D. z. Nedden Crossing Vessels at the Ureteropelvic Junction: Detection with Contrast-enhanced Color Doppler Imaging Radiology, March 1, 1999; 210(3): 727 - 731. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |