Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shreve, P. D.
Right arrow Articles by Wahl, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shreve, P. D.
Right arrow Articles by Wahl, R. L.

Radiology, Vol 207, 431-437, Copyright © 1998 by Radiological Society of North America


ARTICLES

Oncologic diagnosis with 2-[fluorine-18]fluoro-2-deoxy-D-glucose imaging: dual-head coincidence gamma camera versus positron emission tomographic scanner

PD Shreve, RS Steventon, EC Deters, PV Kison, MD Gross and RL Wahl
Department of Nuclear Medicine, Department of Veterans Affairs Medical Center, Ann Arbor, Mich. 48109-0028, USA.

PURPOSE: To compare the performance of a dual-head single photon emission computed tomographic (SPECT) Anger camera operated in coincidence mode with that of a dedicated positron emission tomographic (PET) scanner in the imaging of cancer with 2-[fluorine-18]fluoro-2- deoxy-D-glucose (FDG). MATERIALS AND METHODS: Thirty-one patients with known or suspected malignant neoplasms underwent imaging with both methods, and the images were read blindly. Diagnostic performance on a lesion-by-lesion basis was compared with attenuation-corrected PET as the standard of reference. RESULTS: Of a total of 109 discrete lesions depicted at PET, 60 (relative sensitivity, 55%) were identified on the coincidence-mode images. Of the nodules or masses depicted at PET, 13 (93%) of 14 lung nodules or masses, 20 (65%) of 31 mediastinal lymph nodes, five (71%) of seven lesions in the neck, five (55%) of nine axillary lymph nodes, 11 (50%) of 22 bone metastases, and six (23%) of 26 abdominal tumor deposits were correctly identified on the coincidence gamma camera images. CONCLUSION: These preliminary findings indicate FDG imaging with a modified dual-detector gamma camera operating in coincidence mode can depict many of the lesions depicted with a PET scanner, particularly in the lungs. Sensitivity for lesions detected at dedicated FDG PET was poor in the abdomen and in all locations outside the lungs for tumor deposits generally less than 1.5 cm in short-axis diameter.


This article has been cited by other articles:


Home page
BloodHome page
T. C. Kwee, R. M. Kwee, and R. A. J. Nievelstein
Imaging in staging of malignant lymphoma: a systematic review
Blood, January 15, 2008; 111(2): 504 - 516.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
M. R. Acker and S. C. Burrell
Utility of 18F-FDG PET in Evaluating Cancers of Lung
J. Nucl. Med. Technol., June 1, 2005; 33(2): 69 - 74.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
E. Even-Sapir, B. Yuzefovich, E. Miller, J.-P. Bouhnik, O. Zak, H. Lerman, G. Lievshitz, and C. Levin
Coincidence Imaging Using 2 Dual-Head {gamma}-Camera Systems, With and Without Attenuation Correction
J. Nucl. Med. Technol., December 1, 2004; 32(4): 190 - 197.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. S. Oturai, J. Mortensen, H. Enevoldsen, A. Eigtved, V. Backer, K. P. Olesen, H. W. Nielsen, H. Hansen, P. Stentoft, and L. Friberg
{gamma}-Camera 18F-FDG PET in Diagnosis and Staging of Patients Presenting with Suspected Lung Cancer and Comparison with Dedicated PET
J. Nucl. Med., August 1, 2004; 45(8): 1351 - 1357.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
M. K. Gould, W. G. Kuschner, C. E. Rydzak, C. C. Maclean, A. N. Demas, H. Shigemitsu, J. K. Chan, and D. K. Owens
Test Performance of Positron Emission Tomography and Computed Tomography for Mediastinal Staging in Patients with Non-Small-Cell Lung Cancer: A Meta-Analysis
Ann Intern Med, December 2, 2003; 139(11): 879 - 892.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
M. K. Gould, G. D. Sanders, P. G. Barnett, C. E. Rydzak, C. C. Maclean, M. B. McClellan, and D. K. Owens
Cost-Effectiveness of Alternative Management Strategies for Patients with Solitary Pulmonary Nodules
Ann Intern Med, May 6, 2003; 138(9): 724 - 735.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
D. J. Kadrmas and P. E. Christian
Comparative Evaluation of Lesion Detectability for 6 PET Imaging Platforms Using a Highly Reproducible Whole-Body Phantom with 22Na Lesions and Localization ROC Analysis
J. Nucl. Med., November 1, 2002; 43(11): 1545 - 1554.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
V. J. Lowe and G. A. Wiseman
Assessment of Lymphoma Therapy Using 18F-FDG PET
J. Nucl. Med., August 1, 2002; 43(8): 1028 - 1030.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
H Zhang, M Tian, N Oriuchi, T Higuchi, S Tanada, and K Endo
Oncological diagnosis using positron coincidence gamma camera with fluorodeoxyglucose in comparison with dedicated PET
Br. J. Radiol., May 31, 2002; 75(893): 409 - 416.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
E. Even-Sapir, H. Lerman, A. Figer, M. Rabau, G. Livshitz, M. Inbar, and M. Gutman
Role of 18F-FDG Dual-Head Gamma-Camera Coincidence Imaging in Recurrent or Metastatic Colorectal Carcinoma
J. Nucl. Med., May 1, 2002; 43(5): 603 - 609.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J.F. Vansteenkiste
Imaging in lung cancer: positron emission tomography scan
Eur. Respir. J., February 1, 2002; 19(35_suppl): 49S - 60s.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. Maurea, M. Klain, C. Mainolfi, M. Ziviello, and M. Salvatore
The Diagnostic Role of Radionuclide Imaging in Evaluation of Patients with Nonhypersecreting Adrenal Masses
J. Nucl. Med., June 1, 2001; 42(6): 884 - 892.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. S. Gambhir, J. Czernin, J. Schwimmer, D. H. S. Silverman, R. E. Coleman, and M. E. Phelps
A Tabulated Summary of the FDG PET Literature
J. Nucl. Med., May 1, 2001; 42(90050): 1S - 93.
[Full Text] [PDF]


Home page
Eur Respir JHome page
J.F. Vansteenkiste and S.G. Stroobants
The role of positron emission tomography with 18F-fluoro-2-deoxy-D-glucose in respiratory oncology
Eur. Respir. J., April 1, 2001; 17(4): 802 - 820.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Tatsumi, H. Kitayama, H. Sugahara, N. Tokita, H. Nakamura, Y. Kanakura, and T. Nishimura
Whole-Body Hybrid PET with 18F-FDG in the Staging of Non-Hodgkin's Lymphoma
J. Nucl. Med., April 1, 2001; 42(4): 601 - 608.
[Abstract] [Full Text]


Home page
Br. J. Radiol.Home page
N J Bird, S E Old, and R W Barber
Gamma camera positron emission tomography
Br. J. Radiol., April 1, 2001; 74(880): 303 - 306.
[Full Text] [PDF]


Home page
JAMAHome page
M. K. Gould, C. C. Maclean, W. G. Kuschner, C. E. Rydzak, and D. K. Owens
Accuracy of Positron Emission Tomography for Diagnosis of Pulmonary Nodules and Mass Lesions: A Meta-analysis
JAMA, February 21, 2001; 285(7): 914 - 924.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Delbeke, W. H. Martin, J. A. Patton, and M. P. Sandler
Value of Iterative Reconstruction,AttenuationCorrection,and Image Fusion in the Interpretation of FDG PET Images with an Integrated Dual-Head Coincidence Camera and X-Ray-based Attenuation Maps
Radiology, January 1, 2001; 218(1): 163 - 171.
[Abstract] [Full Text]


Home page
JNMHome page
V. Bousson, J.-L. Moretti, P. Weinmann, N. Safi, F. Tamgac, C. Groiselle, V. de Beco, Y. Hillali, D. Valeyre, and J.-L. Breau
Assessment of Malignancy in Pulmonary Lesions: FDG Dual-Head Coincidence Gamma Camera Imaging in Association with Serum Tumor Marker Measurement
J. Nucl. Med., November 1, 2000; 41(11): 1801 - 1807.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
K. Fukuchi, K. Hayashida, H. Moriwaki, K. Fukushima, N. Kume, T. Katafuchi, M. Sago, M. Takamiya, and Y. Ishida
Brain Fluorine-18 Fluorodeoxyglucose Imaging with Dual-Head Coincidence Gamma Camera:Comparison with Dedicated Ring-Detector PositronEmission Tomography
AJNR Am. J. Neuroradiol., January 1, 2000; 21(1): 99 - 104.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. E. Coleman, C. M. Laymon, and T. G. Turkington
FDG Imaging of Lung Nodules: A Phantom Study Comparing SPECT, Camera-based PET, and Dedicated PET
Radiology, March 1, 1999; 210(3): 823 - 828.
[Abstract] [Full Text]


Home page
ChestHome page
J. E. Blum, H. Handmaker, and N. A. Rinne
The Utility of a Somatostatin-Type Receptor Binding Peptide Radiopharmaceutical (P829) in the Evaluation of Solitary Pulmonary Nodules
Chest, January 1, 1999; 115(1): 224 - 232.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.