|
|
||||||||
Radiology, Vol 207, 657-662, Copyright © 1998 by Radiological Society of North America
ARTICLES |
KT Bae, JP Heiken and JA Brink
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO 63110, USA.
PURPOSE: To investigate how reduction in cardiac output affects the magnitude and timing of aortic and hepatic contrast medium enhancement during abdominal computed tomography (CT). MATERIALS AND METHODS: Eight 20-30-kg pigs underwent CT before and after pharmacologic reduction of cardiac output (measured by means of thermodilution). Each CT study consisted of 53 dynamic images acquired every 5 seconds at a fixed level through the midliver after intravenous injection of contrast medium (concentration, 282 mg of iodine per milliliter; dose, 2 mL per kilogram of body weight; injection rate, 2 mL/sec). Curves of contrast medium enhancement versus time were measured. Changes in the magnitude and timing of aortic and hepatic enhancement were compared with the reduction in cardiac output. RESULTS: With reduction in cardiac output, the time from the injection start to the arrival of the contrast medium bolus in the aorta (P < .01) and the times from injection completion to peak aortic (P < .01) and peak hepatic (P < .01) enhancement increased. As cardiac output decreased, peak aortic enhancement increased proportionally (P < .01). Peak hepatic enhancement increased only slightly and correlated weakly with the decrease in cardiac output (P = .07). CONCLUSION: As cardiac output decreases, the times to the arrival of the contrast medium bolus in the aorta and to peak aortic and hepatic enhancement increase. Reduction in cardiac output results in a substantial increase in peak aortic enhancement but not in peak hepatic enhancement.
This article has been cited by other articles:
![]() |
F. F. Behrendt, A. H. Mahnken, S. Stanzel, P. Seidensticker, E. Jost, R. W. Gunther, and G. Muhlenbruch Intraindividual Comparison of Contrast Media Concentrations for Combined Abdominal and Thoracic MDCT Am. J. Roentgenol., July 1, 2008; 191(1): 145 - 150. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, H. Rusinek, L. Bokacheva, A. J. Huang, N. Oesingmann, Q. Chen, M. Kaur, K. Prince, T. Song, E. L. Kramer, et al. Renal function measurements from MR renography and a simplified multicompartmental model Am J Physiol Renal Physiol, May 1, 2007; 292(5): F1548 - F1559. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kondo, M. Kanematsu, S. Goshima, T. Miyoshi, Y. Shiratori, M. Onozuka, N. Moriyama, and K. T. Bae MDCT of the Pancreas: Optimizing Scanning Delay with a Bolus-Tracking Technique for Pancreatic, Peripancreatic Vascular, and Hepatic Contrast Enhancement Am. J. Roentgenol., March 1, 2007; 188(3): 751 - 756. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Itoh, M. Ikeda, H. Satake, T. Ota, and T. Ishigaki The effect of patient age on contrast enhancement during CT of the pancreatobiliary region. Am. J. Roentgenol., August 1, 2006; 187(2): 505 - 510. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Goshima, M. Kanematsu, H. Kondo, R. Yokoyama, T. Miyoshi, H. Nishibori, H. Kato, H. Hoshi, M. Onozuka, and N. Moriyama MDCT of the liver and hypervascular hepatocellular carcinomas: optimizing scan delays for bolus-tracking techniques of hepatic arterial and portal venous phases. Am. J. Roentgenol., July 1, 2006; 187(1): W25 - W32. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, A. Hatcho, Y. Nakayama, S. Kusunoki, D. Liu, M. Hatemura, Y. Funama, M. Denbo, N. Sato, and Y. Yamashita Simulation of Aortic Peak Enhancement on MDCT Using a Contrast Material Flow Phantom: Feasibility Study Am. J. Roentgenol., February 1, 2006; 186(2): 379 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae Peak Contrast Enhancement in CT and MR Angiography: When Does It Occur and Why? Pharmacokinetic Study in a Porcine Model Radiology, June 1, 2003; 227(3): 809 - 816. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Lee, T. K. Kim, J. H. Byun, H. K. Ha, P. N. Kim, A. Y. Kim, S. G. Lee, and M.-G. Lee Hepatic Arteries in Potential Donors for Living Related Liver Transplantation: Evaluation with Multi-Detector Row CT Angiography Radiology, May 1, 2003; 227(2): 391 - 399. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D. Rubin, A. J. Schmidt, L. J. Logan, and M. C. Sofilos Multi-Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience Radiology, October 1, 2001; 221(1): 146 - 158. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Fleischmann, G. D. Rubin, A. A. Bankier, and K. Hittmair Improved Uniformity of Aortic Enhancement with Customized Contrast Medium Injection Protocols at CT Angiography Radiology, February 1, 2000; 214(2): 363 - 371. [Abstract] [Full Text] |
||||
![]() |
V. S. Lee, N. M. Rofsky, G. A. Krinsky, D. H. Stemerman, and J. C. Weinreb Single-Dose Breath-hold Gadolinium-enhanced Three-dimensional MR Angiography of the Renal Arteries Radiology, April 1, 1999; 211(1): 69 - 78. [Abstract] [Full Text] |
||||
![]() |
D. S. Gierada and K. T. Bae Gadolinium as a CT Contrast Agent: Assessment in a Porcine Model Radiology, March 1, 1999; 210(3): 829 - 834. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |