Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kwak, S. M.
Right arrow Articles by Resnick, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kwak, S. M.
Right arrow Articles by Resnick, D.

Radiology, Vol 208, 375-380, Copyright © 1998 by Radiological Society of North America


ARTICLES

Glenohumeral joint: comparison of shoulder positions at MR arthrography

SM Kwak, RR Brown, D Trudell and D Resnick
Department of Radiology, Veterans Administration Medical Center, San Diego, USA.

PURPOSE: To compare neutral, external rotation, and abduction external rotation positions of the glenohumeral joint during magnetic resonance (MR) arthrography in the assessment of the joint capsule, biceps-labral complex, and glenohumeral ligaments. MATERIALS AND METHODS: MR imaging with intraarticular administration of gadopentetate dimeglumine was performed in 10 adult cadaveric glenohumeral joints. Fat-suppressed oblique coronal, oblique sagittal, and axial. T1-weighted spin-echo imaging and axial three-dimensional spoiled gradient-recalled imaging were performed with each shoulder in the neutral, external rotation, and abduction external rotation positions. Shoulders were sectioned in the planes that yielded optimal MR images. Anatomic and MR imaging findings were correlated. RESULTS: The biceps-labral complex was best visualized on oblique coronal and axial images obtained in external rotation. Oblique axial abduction external rotation imaging best delineated the inferior glenohumeral ligament but did not improve assessment of the superior and middle glenohumeral ligaments in comparison with findings in neutral and external rotation. CONCLUSION: Although MR arthrography of the glenohumeral joint clearly delineates the biceps-labral complex and glenohumeral ligaments, external rotation of the shoulder optimizes visualization of the former structures. Abduction external rotation is the best position for evaluation of the inferior glenohumeral ligament and anterior capsular attachment.


This article has been cited by other articles:


Home page
RadioGraphicsHome page
L. S. Steinbach, W. E. Palmer, and M. E. Schweitzer
Special Focus Session: MR Arthrography
RadioGraphics, September 1, 2002; 22(5): 1223 - 1246.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Sugimoto, K. Suzuki, K.-i. Mihara, H. Kubota, and H. Tsutsui
MR Arthrography of Shoulders after Suture-Anchor Bankart Repair
Radiology, July 1, 2002; 224(1): 105 - 111.
[Abstract] [Full Text]


Home page
RadiologyHome page
M. V. Hammar, G. B. Wintzell, K. G. O. Åström, S. Larsson, and A. Elvin
Role of US in the Preoperative Evaluation of Patients with Anterior Shoulder Instability
Radiology, April 1, 2001; 219(1): 29 - 34.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.