Radiology, Vol 209, 111-116, Copyright © 1998 by Radiological Society of North America
ARTICLES |
JE Silberzweig, ML Marin, LH Hollier, HA Mitty, RE Parsons, JM Cooper and J Ahn
Department of Radiology, Mount Sinai Medical Center, New York, NY, USA.
PURPOSE: To evaluate aortoiliac aneurysms repaired with endovascular stent-grafts complicated by hemodynamically significant graft stenosis. MATERIALS AND METHODS: Fifty-four patients (52 men, two women; age range, 41-90 years; mean age, 75 years) with aneurysms of the infrarenal aorta (n = 36) or iliac artery (n = 18) underwent repair by means of placement of an endovascular stent-graft. Technical success was evaluated angiographically during and after placement. At follow-up (range, 12-44 months), all patients underwent sequential duplex ultrasonography, helical computed tomography, and physical examination. RESULTS: Stent-grafts were placed successfully in all cases. Stenosis at the internal iliac arterial origin was identified at angiography in 17 patients (31%). Supplemental intragraft stents were placed in 11 patients, and stent-graft angioplasty alone was performed in one patient. Intragraft stents were placed percutaneously in five patients when stenosis was discovered during follow-up. CONCLUSION: Supplemental intragraft stents were required in 31% of aortoiliac endovascular stent- grafts to correct stent-graft stenosis and preserve long-term function. Placement of a fully supported stent-graft is necessary to repair an aortoiliac aneurysm.
This article has been cited by other articles:
![]() |
M. Schoder, L. Zaunbauer, T. Holzenbein, D. Fleischmann, M. Cejna, G. Kretschmer, S. Thurnher, and J. Lammer Internal Iliac Artery Embolization Before Endovascular Repair of Abdominal Aortic Aneurysms: Frequency, Efficacy, and Clinical Results Am. J. Roentgenol., September 1, 2001; 177(3): 599 - 605. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Silberzweig, M. L. Marin, L. H. Hollier, H. A. Mitty, and T. L. Connelly Balloon-Expandable Common Iliac Artery Occluder Device for Endovascular Aneurysm Repair Vascular and Endovascular Surgery, July 1, 2001; 35(4): 263 - 271. [Abstract] [PDF] |
||||
![]() |
T. Mita, T. Arita, N. Matsunaga, M. Furukawa, N. Zempo, K. Esato, and M. Matsuzaki Complications of Endovascular Repair for Thoracic and Abdominal Aortic Aneurysm: An Imaging Spectrum RadioGraphics, September 1, 2000; 20(5): 1263 - 1278. [Abstract] [Full Text] [PDF] |
||||
![]() |