|
|
||||||||
Radiology, Vol 209, 129-134, Copyright © 1998 by Radiological Society of North America
ARTICLES |
TR Bader, AM Herneth, W Blaicher, R Steininger, F Muhlbacher, G Lechner and F Grabenwoger
Department of Radiology, University of Vienna, Austria.
PURPOSE: To compare hepatic perfusion values after orthotopic liver transplantation with those in healthy volunteers. MATERIALS AND METHODS: Dynamic single-section computed tomography (CT) of the liver was performed in 50 participants, including 30 study patients who had undergone orthotopic liver transplantation and had no clinical evidence of postoperative complications (mean age, 53.7 years) and 20 healthy volunteers (control subjects) (mean age, 59.0 years). CT scans were obtained at a single level to include the liver, spleen, aorta, and portal vein. Scans were obtained over 88 seconds (one baseline scan followed by 16 scans every 2 seconds and, then, eight scans every 7 seconds) beginning with the injection of 40 mL of contrast agent (flow rate, 10 mL/sec). On each CT scan, the attenuation of these organs was measured in regions of interest to provide time-attenuation curves. From these data, the arterial, portal venous, and total perfusion of the liver were calculated, and the hepatic perfusion index was assessed. RESULTS: In control subjects and study patients, respectively, mean arterial hepatic perfusion was 0.16 and 0.25 mL/min/mL (P = .001 [two-tailed paired Student t test]), mean portal venous perfusion was 1.22 and 1.26 mL/min/mL, mean total liver perfusion was 1.38 and 1.50 mL/min/mL (difference not significant), and the mean hepatic perfusion index was 0.12 and 0.16 (P = .002). CONCLUSION: Arterial hepatic perfusion was significantly increased after orthotopic liver transplantation, but differences in portal venous and total liver perfusion were not significant. Dynamic single- section CT might also help evaluate hepatic vascular complications, chronic transplant rejection, and hepatic perfusion in liver cirrhosis.
This article has been cited by other articles:
![]() |
S MIYAZAKI, K MURASE, T YOSHIKAWA, S MORIMOTO, Y OHNO, and K SUGIMURA A quantitative method for estimating hepatic blood flow using a dual-input single-compartment model Br. J. Radiol., October 1, 2008; 81(970): 790 - 800. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Ma, A. E. Samir, N.-S. Holalkere, and D. V. Sahani Optimal Arterial Phase Imaging for Detection of Hypervascular Hepatocellular Carcinoma Determined by Continuous Image Capture on 16-MDCT Am. J. Roentgenol., September 1, 2008; 191(3): 772 - 777. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. I. Sainani, O. A. Catalano, N.-S. Holalkere, A. X. Zhu, P. F. Hahn, and D. V. Sahani Cholangiocarcinoma: Current and Novel Imaging Techniques RadioGraphics, September 1, 2008; 28(5): 1263 - 1287. [Abstract] [Full Text] [PDF] |
||||
![]() |
K Murase, S Miyazaki, and X Yang An efficient method for calculating kinetic parameters in a dual-input single-compartment model Br. J. Radiol., May 1, 2007; 80(953): 371 - 375. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Schueller, W. Schima, C. Schueller-Weidekamm, M. Weber, A. Stift, M. Gnant, and R. Prokesch Multidetector CT of Pancreas: Effects of Contrast Material Flow Rate and Individualized Scan Delay on Enhancement of Pancreas and Tumor Contrast Radiology, November 1, 2006; 241(2): 441 - 448. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Weidekamm, M. Cejna, L. Kramer, M. Peck-Radosavljevic, and T. R. Bader Effects of TIPS on Liver Perfusion Measured by Dynamic CT Am. J. Roentgenol., February 1, 2005; 184(2): 505 - 510. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Nakashige, J Horiguchi, A Tamura, T Asahara, F Shimamoto, and K Ito Quantitative measurement of hepatic portal perfusion by multidetector row CT with compensation for respiratory misregistration Br. J. Radiol., September 1, 2004; 77(921): 728 - 734. [Abstract] [Full Text] [PDF] |
||||
![]() |
K A Miles Perfusion CT for the assessment of tumour vascularity: which protocol? Br. J. Radiol., December 1, 2003; 76(suppl_1): S36 - S42. [Abstract] [Full Text] [PDF] |
||||
![]() |
K A Miles and M R Griffiths Perfusion CT: a worthwhile enhancement? Br. J. Radiol., April 1, 2003; 76(904): 220 - 231. [Full Text] [PDF] |
||||
![]() |
B. E. Van Beers, I. Leconte, R. Materne, A. M. Smith, J. Jamart, and Y. Horsmans Hepatic Perfusion Parameters in Chronic Liver Disease: Dynamic CT Measurements Correlated with Disease Severity Am. J. Roentgenol., March 1, 2001; 176(3): 667 - 673. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Fleischmann, G. D. Rubin, A. A. Bankier, and K. Hittmair Improved Uniformity of Aortic Enhancement with Customized Contrast Medium Injection Protocols at CT Angiography Radiology, February 1, 2000; 214(2): 363 - 371. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |