Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Audet, P.
Right arrow Articles by Cusson, J. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Audet, P.
Right arrow Articles by Cusson, J. R.

Radiology, Vol 209, 357-363, Copyright © 1998 by Radiological Society of North America


ARTICLES

Infrarenal aortic stenosis: long-term clinical and hemodynamic results of percutaneous transluminal angioplasty

P Audet, E Therasse, VL Oliva, G Soulez, G Cote, R Wistaff, PV Nguyen, JF Blair, BT Bui and JR Cusson
Dept of Radiology, Univ of Montreal Medical Center, Quebec, Canada.

PURPOSE: To evaluate the safety and long-term clinical and hemodynamic results of percutaneous transluminal angioplasty (PTA) of the infrarenal aorta. MATERIALS AND METHODS: During nearly 10 years, 102 patients with symptomatic infrarenal atherosclerotic aortic stenosis underwent PTA. Follow-up information was available in 92 patients (17 men, 75 women; mean age, 51.9 years). Stenosis involved the aortic bifurcation in 18 patients and only the infrarenal abdominal aorta in 74 patients. Technical success was defined as residual stenosis less than 50% or a pressure gradient less than 10 mm Hg after PTA. Clinical patency was defined as the absence or improvement of symptoms after PTA. Hemodynamic patency was defined as a normal Doppler waveform in the common femoral arteries, an ankle-brachial ratio greater than 0.95, or the absence of a thigh-brachial pressure gradient. RESULTS: Technical success was achieved in 78 patients after PTA. After 10 years, primary clinical and hemodynamic patency rates were 72% and 46%, respectively. After a mean follow-up of 51 months, 15 of the 22 symptomatic recurrences were due to aortic restenosis; 11 of these were treated with repeated PTA with or without stent placement, and three eventually required aortic surgery. No morbidity was encountered. CONCLUSION: Infrarenal aortic PTA proved to be safe and provided durable, long-term clinical improvement. In this group of relatively young patients, the clinical patency rate of PTA was equivalent to that of aortic surgery but with less morbidity.


This article has been cited by other articles:


Home page
RadiologyHome page
E. Therasse, G. Cote, V. L. Oliva, J. R. Cusson, R. Wistaff, P. V. Nguyen, B. T. Bui, P. Perreault, L. Lamarre, and G. Soulez
Infrarenal Aortic Stenosis: Value of Stent Placement after Percutaneous Transluminal Angioplasty Failure
Radiology, June 1, 2001; 219(3): 655 - 662.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.