Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Starck, G.
Right arrow Articles by Ekholm, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Starck, G.
Right arrow Articles by Ekholm, S.

Radiology, Vol 209, 397-403, Copyright © 1998 by Radiological Society of North America


ARTICLES

Radiation dose reduction in CT: application to tissue area and volume determination

G Starck, L Lonn, A Cederblad, M Alpsten, L Sjostrom and S Ekholm
Division of Medical Physics and Medical Engineering, Sahlgrenska University Hospital, MR Centre, Gothenburg, Sweden.

PURPOSE: To study the potential for radiation dose reduction in computed tomographic (CT) determination of adipose and muscle tissue area and volume, which is an application in which lower spatial resolution or higher image noise can be accepted. MATERIALS AND METHODS: Measurements in vivo (in a healthy man aged 52 years; weight, 80 kg) and in phantoms were performed with two standard clinical CT scanners. Tissue areas were determined, and measurement uncertainties were analyzed. Comparisons were made with simulated and theoretic data. RESULTS: A 25-fold reduction in radiation dose was achieved and resulted in an effective dose of 13 microSv per section; an accuracy of greater than 5% in area measurements was maintained. The dose savings achieved in this study were close to those that are theoretically possible. CONCLUSION: Further dose reduction to about 1 microSv may be possible for this application. Large dose reductions are possible in CT determinations of tissue area and volume, which makes this application available also in large randomized studies in which high-performance clinical standard scanners are used. This work demonstrates that modern CT technology may have a large potential for dose reduction in specific applications.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
J BRANDBERG, L LONN, E BERGELIN, L SJOSTROM, E FORSSELL-ARONSSON, and G STARCK
Accurate tissue area measurements with considerably reduced radiation dose achieved by patient-specific CT scan parameters
Br. J. Radiol., October 1, 2008; 81(970): 801 - 808.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. J. Golding
Multi-slice computed tomography (MSCT): the dose challenge of the new revolution
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 303 - 307.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Itoh, M. Ikeda, Y. Mori, K. Suzuki, A. Sawaki, S. Iwano, H. Satake, S. Arahata, T. Isomura, M. Ozaki, et al.
Lung: Feasibility of a Method for Changing Tube Current during Low-Dose Helical CT
Radiology, September 1, 2002; 224(3): 905 - 912.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
G Starck, L Lonn, A Cederblad, E Forssell-Aronsson, L Sjostrom, and M Alpsten
A method to obtain the same levels of CT image noise for patients of various sizes, to minimize radiation dose
Br. J. Radiol., February 1, 2002; 75(890): 140 - 150.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S J Golding and P C Shrimpton
Radiation dose in CT: are we meeting the challenge?
Br. J. Radiol., January 1, 2002; 75(889): 1 - 4.
[Full Text] [PDF]


Home page
RadiologyHome page
W. Huda, E. M. Scalzetti, and G. Levin
Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CT
Radiology, November 1, 2000; 217(2): 430 - 435.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.