Radiology, Vol 209, 411-416, Copyright © 1998 by Radiological Society of North America
ARTICLES |
JE Jacobs, BA Birnbaum and CP Langlotz
Department of Radiology, University of Pennsylvania Medical Center, Philadelphia 19104, USA.
PURPOSE: To evaluate the belief that the frequencies of contrast material extravasation and minor, nonidiosyncratic contrast material reactions correlate with intravenous injection rates. MATERIALS AND METHODS: Complications of 6,660 consecutive injections of contrast material for computed tomography were prospectively recorded. Ionic (n = 4,851) or nonionic (n = 1,809) contrast material was injected at 0.5- 4.0 mL/sec. The injection rate was 1.9 mL/sec or less in group 1 (n = 2,899), 2.0-2.9 mL/sec in group 2 (n = 2,475), and 3.0-4.0 mL/sec in group 3 (n = 1,286). RESULTS: The extravasation rate (0.6%) did not differ significantly between the groups. The reaction rate (8.4%) also did not differ significantly between the groups. The rate of minor reactions (8.0%) was higher with ionic (9.9%) than nonionic (2.9%) contrast material (relative risk = 3.4). The rate of major reactions (0.4%) did not vary significantly with type of contrast material. The rate of nausea or vomiting (3.8%) did not differ significantly between the groups but was higher with ionic (4.9%) than nonionic (1.1%) contrast material (relative risk = 4.5). The rate of severe warmth (2.1%) was significantly higher in group 3 (2.8%) than group 1 (2.0%) or 2 (1.8%). CONCLUSION: No correlations exist between injection rate and extravasation rate or overall reaction rate.
This article has been cited by other articles:
![]() |
F. F. Behrendt, A. H. Mahnken, S. Stanzel, P. Seidensticker, E. Jost, R. W. Gunther, and G. Muhlenbruch Intraindividual Comparison of Contrast Media Concentrations for Combined Abdominal and Thoracic MDCT Am. J. Roentgenol., July 1, 2008; 191(1): 145 - 150. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. L. Wang, R. H. Cohan, J. H. Ellis, S. Adusumilli, and N. R. Dunnick Frequency, Management, and Outcome of Extravasation of Nonionic Iodinated Contrast Medium in 69 657 Intravenous Injections Radiology, April 1, 2007; 243(1): 80 - 87. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Amaral, J. Traubici, G. BenDavid, G. Reintamm, and A. Daneman Safety of power injector use in children as measured by incidence of extravasation. Am. J. Roentgenol., August 1, 2006; 187(2): 580 - 583. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Schima, R. Hammerstingl, C. Catalano, L. Marti-Bonmati, E. J. Rummeny, F. T. Montero, A. Dirisamer, B. Westermayer, M. Bellomi, D. Brisbois, et al. Quadruple-phase MDCT of the liver in patients with suspected hepatocellular carcinoma: effect of contrast material flow rate. Am. J. Roentgenol., June 1, 2006; 186(6): 1571 - 1579. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.-F. Ko, C.-C. Huang, S.-H. Ng, T.-Y. Lee, M.-J. Hsieh, F.-Y. Lee, M.-C. Chen, S.-M. Sheen-Chen, and C.-H. Lee MDCT Angiography for Evaluation of the Complete Vascular Tree of Hemodialysis Fistulas Am. J. Roentgenol., November 1, 2005; 185(5): 1268 - 1274. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, M. Inoue, Y. Yagyu, M. Watanabe, T. Sano, S. Nin, R. Koike, Y. Nishimura, and Y. Yamashita Moderate versus High Concentration of Contrast Material for Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast at Multi-Detector Row CT Radiology, December 1, 2004; 233(3): 682 - 688. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. T. Cochran, K. Bomyea, and J. W. Sayre Trends in Adverse Events After IV Administration of Contrast Media Am. J. Roentgenol., June 1, 2001; 176(6): 1385 - 1388. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Birnbaum, R. C. Nelson, J. L. Chezmar, and S. N. Glick Extravasation Detection Accessory: Clinical Evaluation in 500 Patients Radiology, August 1, 1999; 212(2): 431 - 438. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |