Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weg, N.
Right arrow Articles by Gabor, M. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weg, N.
Right arrow Articles by Gabor, M. P.

Radiology, Vol 209, 417-426, Copyright © 1998 by Radiological Society of North America


ARTICLES

Liver lesions: improved detection with dual-detector-array CT and routine 2.5-mm thin collimation

N Weg, MR Scheer and MP Gabor
Dr Noah Weg & Associates, Suffern, NY 10901, USA.

PURPOSE: To determine the feasibility and clinical benefit of routine performance of helical computed tomography (CT) with 2.5-mm collimation for the detection of liver lesions. MATERIALS AND METHODS: Twenty patients with small (< or = 10-mm-diameter) liver lesions (total number of lesions, 167) were evaluated with a dual-detector-array CT scanner during the portal venous phase of contrast material enhancement. The acquisition was performed with 2.5-mm collimation during a single breath hold. The identical data set was used to perform reconstructions with 2.5-mm, 5.0-mm, 7.5-mm, and 10.0-mm section thicknesses with 50% section overlap. Each set of images was evaluated by three radiologists to determine lesion detection rates and conspicuity. RESULTS: Use of 2.5-mm-thick sections resulted in a 46% increase in detection rate versus use of 10.0-mm-thick sections (167 lesions vs 90 lesions), a 33% increase versus use of 7.5-mm-thick sections (167 vs 112), and an 18% increase versus use of 5-mm-thick sections (167 vs 137). Lesion conspicuity and radiologist confidence in lesion detection and characterization of lesion margins increased as section thickness decreased. CONCLUSION: CT of the liver can be performed routinely with 2.5-mm collimation with a dual-detector CT system, yielding greater conspicuity of small lesions and improved lesion detection.


This article has been cited by other articles:


Home page
Ann. Surg. Oncol.Home page
T. M. Pawlik, D. Laheru, R. H. Hruban, J. Coleman, C. L. Wolfgang, K. Campbell, S. Ali, E. K. Fishman, R. D. Schulick, J. M. Herman, et al.
Evaluating the Impact of a Single-Day Multidisciplinary Clinic on the Management of Pancreatic Cancer
Ann. Surg. Oncol., August 1, 2008; 15(8): 2081 - 2088.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al.
Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology
Eur. Heart J., February 2, 2008; 29(4): 531 - 556.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Iezzi, A. R. Cotroneo, A. Filippone, F. Di Fabio, M. Santoro, and M. L. Storto
MDCT Angiography in Abdominal Aortic Aneurysm Treated with Endovascular Repair: Diagnostic Impact of Slice Thickness on Detection of Endoleaks
Am. J. Roentgenol., December 1, 2007; 189(6): 1414 - 1420.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. J. Parrish
Volume CT: State-of-the-Art Reporting
Am. J. Roentgenol., September 1, 2007; 189(3): 528 - 534.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Onishi, T. Murakami, T. Kim, M. Hori, R. Iannaccone, M. Kuwabara, H. Abe, S. Nakata, K. Osuga, K. Tomoda, et al.
Hepatic Metastases: Detection with Multi-Detector Row CT, SPIO-enhanced MR Imaging, and Both Techniques Combined
Radiology, April 1, 2006; 239(1): 131 - 138.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Ward, P. J. Robinson, J. A. Guthrie, S. Downing, D. Wilson, J. P. A. Lodge, K. R. Prasad, G. J. Toogood, and J. I. Wyatt
Liver Metastases in Candidates for Hepatic Resection: Comparison of Helical CT and Gadolinium- and SPIO-enhanced MR Imaging
Radiology, October 1, 2005; 237(1): 170 - 180.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. H. Kim, D. Choi, S. H. Kim, J. H. Lim, W. J. Lee, M. J. Kim, H. K. Lim, and S. J. Lee
Ferucarbotran-Enhanced MRI Versus Triple-Phase MDCT for the Preoperative Detection of Hepatocellular Carcinoma
Am. J. Roentgenol., April 1, 2005; 184(4): 1069 - 1076.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. K. Kim, C. S. Kim, G. H. Chung, S. B. Jeon, and J. M. Lee
Feasibility of Application of Sensitivity Encoding to the Breath-Hold T2-Weighted Turbo Spin-Echo Sequence for Evaluation of Focal Hepatic Tumors
Am. J. Roentgenol., February 1, 2005; 184(2): 497 - 504.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P J Robinson, P Arnold, and D Wilson
Small "indeterminate" lesions on CT of the liver: a follow-up study of stability
Br. J. Radiol., December 1, 2003; 76(912): 866 - 874.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. A. Haider, M. M. Amitai, D. C. Rappaport, M. E. O'Malley, A. E. Hanbidge, M. Redston, G. A. Lockwood, and S. Gallinger
Multi-Detector Row Helical CT in Preoperative Assessment of Small (<=1.5 cm) Liver Metastases: Is Thinner Collimation Better?
Radiology, October 1, 2002; 225(1): 137 - 142.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Kawata, T. Murakami, T. Kim, M. Hori, M. P. Federle, S. Kumano, E. Sugihara, S. Makino, H. Nakamura, and M. Kudo
Multidetector CT: Diagnostic Impact of Slice Thickness on Detection of Hypervascular Hepatocellular Carcinoma
Am. J. Roentgenol., July 1, 2002; 179(1): 61 - 66.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. G. Fletcher, C. D. Johnson, W. R. Krueger, D. A. Ahlquist, H. Nelson, D. Ilstrup, W. S. Harmsen, and K. E. Corcoran
Contrast-Enhanced CT Colonography in Recurrent Colorectal Carcinoma: Feasibility of Simultaneous Evaluation for Metastatic Disease, Local Recurrence, and Metachronous Neoplasia in Colorectal Carcinoma
Am. J. Roentgenol., February 1, 2002; 178(2): 283 - 290.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
H. Ji, J. D. McTavish, K. J. Mortele, W. Wiesner, and P. R. Ros
Hepatic Imaging with Multidetector CT
RadioGraphics, October 1, 2001; 21(90001): S71 - 80.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
U. J. Schoepf, R. D. Bruening, C. Hong, R. Eibel, S. Aydemir, A. Crispin, C. Becker, and M. F. Reiser
Multislice Helical CT of Focal and Diffuse Lung Disease: Comprehensive Diagnosis with Reconstruction of Contiguous and High-Resolution CT Sections from a Single Thin-Collimation Scan
Am. J. Roentgenol., July 1, 2001; 177(1): 179 - 184.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Kim, M. P. Federle, R. L. Baron, M. S. Peterson, and Y. Kawamori
Discrimination of Small Hepatic Hemangiomas from Hypervascular Malignant Tumors Smaller than 3 cm with Three-Phase Helical CT
Radiology, June 1, 2001; 219(3): 699 - 706.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. K. Hara, C. D. Johnson, R. L. MacCarty, T. J. Welch, C. H. McCollough, and W. S. Harmsen
CT Colonography: Single- versus Multi-Detector Row Imaging
Radiology, May 1, 2001; 219(2): 461 - 465.
[Abstract] [Full Text]


Home page
RadiologyHome page
K. Wong, E. K. Paulson, and R. C. Nelson
Breath-hold Three-dimensional CT of the Liver with Multi-Detector Row Helical CT
Radiology, April 1, 2001; 219(1): 75 - 79.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
B. S. Kuszyk, D. A. Bluemke, M. A. Choti, K. M. Horton, C. A. Magee, and E. K. Fishman
Contrast-Enhanced CT of Small Hypovascular Hepatic Tumors: Effect of Lesion Enhancement on Conspicuity in Rabbits
Am. J. Roentgenol., February 1, 2000; 174(2): 471 - 0.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
Skutta, Fürst, Eilers, Ferbert, and Kuhn
Intracranial Stenoocclusive Disease: Double-Detector Helical CT Angiography versus Digital Subtraction
AJNR Am. J. Neuroradiol., May 1, 1999; 20(5): 791 - 799.
[Abstract] [Full Text]


Home page
RadiologyHome page
U. J. Schoepf, N. Holzknecht, T. K. Helmberger, A. Crispin, C. Hong, C. R. Becker, and M. F. Reiser
Subsegmental Pulmonary Emboli: Improved Detection with Thin-Collimation Multi-Detector Row Spiral CT
Radiology, February 1, 2002; 222(2): 483 - 490.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1998 by the Radiological Society of North America.