|
|
||||||||
Radiology, Vol 209, 689-695, Copyright © 1998 by Radiological Society of North America
ARTICLES |
HP McAdams, SM Palmer, JJ Erasmus, EF Patz, JE Connolly, PC Goodman, DM Delong and VF Tapson
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA.
PURPOSE: To compare the accuracy of virtual bronchoscopy (VB) with that of axial computed tomography (CT) in the assessment of bronchial anastomotic complications in lung transplant recipients. MATERIALS AND METHODS: Twenty-seven bronchial anastomoses in 17 patients were evaluated with helical CT. Axial CT and VB images were evaluated for surface irregularity and the presence, length, and severity of stenosis. Findings were correlated with the results of fiberoptic bronchoscopy (FOB). RESULTS: There were 12 anastomotic stenoses at FOB. Pooled accuracy (among all four readers) of VB and axial CT for diagnosis of clinically relevant stenosis was 97% and 80%, respectively, at the right bronchial anastomoses and 92% and 75%, respectively, at the left bronchial anastomoses. Pooled accuracy of VB and Axial CT for stenosis length was 72% and 62%, respectively, at the right anastomoses and 81% and 69%, respectively, at the left anastomoses. These differences were not statistically significant. Both the VB and axial CT images showed surface irregularities when anastomotic infection (n = 2) or dehiscence (n = 1) was present but resulted in an overdiagnosis of mucosal abnormalities when anastomoses were normal. CONCLUSION: VB was slightly more accurate than axial CT for diagnosis of clinically relevant stenoses at bronchial anastomoses in lung transplant recipients. However, because VB is not 100% accurate and has no role in the diagnosis of infection or dehiscence, it probably will not replace FOB for assessment of bronchial anastomotic complications in this population.
This article has been cited by other articles:
![]() |
R. R. Gill, A. C. Poh, P. C. Camp, J. M. Allen, M. T. Delano, F. L. Jacobson, A. Hunsaker, and Y. L. Colson MDCT Evaluation of Central Airway and Vascular Complications of Lung Transplantation Am. J. Roentgenol., October 1, 2008; 191(4): 1046 - 1056. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. M. Horton, M. R. Horton, and E. K. Fishman Advanced Visualization of Airways with 64-MDCT: 3D Mapping and Virtual Bronchoscopy Am. J. Roentgenol., December 1, 2007; 189(6): 1387 - 1396. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Schertler, D. Lardinois, T. Boehm, W. Weder, S. Wildermuth, and H. Alkadhi Lung transplantation in Kartagener syndrome and situs inversus: Potential of multidetector row computed tomography and three-dimensional postprocessing J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 814 - 815. [Full Text] [PDF] |
||||
![]() |
D. Shitrit, P. Valdsislav, A. Grubstein, D. Bendayan, M. Cohen, and M. R. Kramer Accuracy of Virtual Bronchoscopy for Grading Tracheobronchial Stenosis: Correlation With Pulmonary Function Test and Fiberoptic Bronchoscopy Chest, November 1, 2005; 128(5): 3545 - 3550. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Jones and T. Athanasiou Is Virtual Bronchoscopy an Efficient Diagnostic Tool for the Thoracic Surgeon? Ann. Thorac. Surg., January 1, 2005; 79(1): 365 - 374. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Kosucu, A. Ahmetoglu, I. Koramaz, F. Orhan, O. Ozdemir, H. Dinc, A. Okten, and H. R. Gumele Low-Dose MDCT and Virtual Bronchoscopy in Pediatric Patients with Foreign Body Aspiration Am. J. Roentgenol., December 1, 2004; 183(6): 1771 - 1777. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Onodera, T. Omatsu, S. Takeuchi, N. Shinagawa, K. Yamazaki, T. Nishioka, and K. Miyasaka Enhanced Virtual Bronchoscopy Using the Pulmonary Artery: Improvement in Route Mapping for Ultraselective Transbronchial Lung Biopsy Am. J. Roentgenol., October 1, 2004; 183(4): 1103 - 1110. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Ernst, D. Feller-Kopman, H. D. Becker, and A. C. Mehta Central Airway Obstruction Am. J. Respir. Crit. Care Med., June 15, 2004; 169(12): 1278 - 1297. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. De Wever, V. Vandecaveye, S. Lanciotti, and J.A. Verschakelen Multidetector CT-generated virtual bronchoscopy: an illustrated review of the potential clinical indications Eur. Respir. J., May 1, 2004; 23(5): 776 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Lacasse, S. Martel, A. Hebert, G. Carrier, and B. Raby Accuracy of virtual bronchoscopy to detect endobronchial lesions Ann. Thorac. Surg., May 1, 2004; 77(5): 1774 - 1780. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. H. Meyer, T. Krueger, D. Lepori, M. Dusmet, J.-D. Aubert, P. Pasche, and H.-B. Ris Closure of large intrathoracic airway defects using extrathoracic muscle flaps Ann. Thorac. Surg., February 1, 2004; 77(2): 397 - 404. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Prince, D. R. Duhamel, D. L. Levin, J. H. Harrell, and P. J. Friedman Nonneoplastic Lesions of the Tracheobronchial Wall: Radiologic Findings with Bronchoscopic Correlation RadioGraphics, October 1, 2002; 22(90001): S215 - 230. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Boiselle, K. F. Reynolds, and A. Ernst Multiplanar and Three-Dimensional Imaging of the Central Airways with Multidetector CT Am. J. Roentgenol., August 1, 2002; 179(2): 301 - 308. [Full Text] [PDF] |
||||
![]() |
P. M. Boiselle and A. Ernst Recent Advances in Central Airway Imaging* Chest, May 1, 2002; 121(5): 1651 - 1660. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. R. Ferretti, F. Thony, J.-L. Bosson, C. Pison, F. Arbib, and M. Coulomb Benign Abnormalities and Carcinoid Tumors of the Central Airways: Diagnostic Impact of CT Bronchography Am. J. Roentgenol., May 1, 2000; 174(5): 1307 - 1313. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |