Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leclerc, X.
Right arrow Articles by Pruvo, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leclerc, X.
Right arrow Articles by Pruvo, J. P.
(Radiology. 1999;210:673-682.)
© RSNA, 1999


Vascular and Interventional Radiology

Internal Carotid Arterial Stenosis: CT Angiography with Volume Rendering

Xavier Leclerc, MD1, Olivier Godefroy, MD, PhD2, Christian Lucas, MD2, Jean-François Benhaim, MD1, Thierry Saint Michel, PhD1, Didier Leys, MD2 and Jean Pierre Pruvo, MD1

1 Departments of Neuroradiology (X.L., J.F.B., T.S.M., J.P.P.)
2 Neurology (O.G., C.L., D.L.), Hôpital Roger Salengro, Boulevard du Professeur Leclercq, 59037 Lille, France.

PURPOSE: To determine the reliability of helical computed tomography (CT) with volume rendering for evaluation of internal carotid arterial stenosis.

MATERIALS AND METHODS: In 22 patients, 44 carotid arteries were evaluated with helical CT and selective conventional angiography. CT data were displayed on volume-rendered and maximum intensity projection (MIP) images. Stenoses were measured separately on axial, volume-rendered, and MIP images and on conventional angiograms. Each artery was then graded as having no stenosis, mild (<30%) stenosis, moderate (30%–70%) stenosis, severe (>70%) stenosis, near occlusion, or occlusion.

RESULTS: One case of stenosis was not assessable at axial CT because of an inappropriate scanning plane; four cases were not assessable at MIP CT because of mural calcifications. All carotid arteries were assessable on volume-rendered images despite no depiction of the residual lumen at the site of narrowing in three cases of near occlusion. Correlations between angiography and helical CT were good. Axial, volume-rendered, and MIP images enabled correct classification of stenosis in 88%, 89%, and 90% of arteries, respectively. CT with volume rendering was slightly more sensitive for determining candidates for endarterectomy (ie, those with >70% stenosis and near occlusion); sensitivity was 100% and specificity, 92%.

CONCLUSION: CT angiography with volume rendering enabled accurate evaluation of carotid disease, even when dense calcifications were present. However, no definite advantage over currently available techniques for CT measurement of stenosis severity was found.

Index terms: Carotid arteries, angiography, 1722.1247, 1722.127 • Carotid arteries, CT, 1722.12112, 1722.12115, 1722.12116, 1722.12117 • Carotid arteries, stenosis or obstruction, 1722.7211, 1722.7212, 1722.7213, 1722.7214, 1722.7215 • Computed tomography (CT), maximum intensity projection, 1722.12115 • Computed tomography (CT), volume rendering, 1722.12112, 1722.12115, 1722.12116, 1722.12117




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
L.S. Babiarz, J.M. Romero, E.K. Murphy, B. Brobeck, P.W. Schaefer, R.G. Gonzalez, and M.H. Lev
Contrast-Enhanced MR Angiography Is Not More Accurate Than Unenhanced 2D Time-of-Flight MR Angiography for Determining >=70% Internal Carotid Artery Stenosis
AJNR Am. J. Neuroradiol., April 1, 2009; 30(4): 761 - 768.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Saba and G. Mallarini
MDCTA of Carotid Plaque Degree of Stenosis: Evaluation of Interobserver Agreement
Am. J. Roentgenol., January 1, 2008; 190(1): W41 - W46.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. K. Chen, P. T. Johnson, K. M. Horton, and E. K. Fishman
Unsuspected Mesenteric Arterial Abnormality: Comparison of MDCT Axial Sections to Interactive 3D Rendering
Am. J. Roentgenol., October 1, 2007; 189(4): 807 - 813.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
L. Saba, G. Caddeo, R. Sanfilippo, R. Montisci, and G. Mallarini
CT and Ultrasound in the Study of Ulcerated Carotid Plaque Compared with Surgical Results: Potentialities and Advantages of Multidetector Row CT Angiography
AJNR Am. J. Neuroradiol., June 1, 2007; 28(6): 1061 - 1066.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
L. Saba, G. Caddeo, R. Sanfilippo, R. Montisci, and G. Mallarini
Efficacy and Sensitivity of Axial Scans and Different Reconstruction Methods in the Study of the Ulcerated Carotid Plaque Using Multidetector-Row CT Angiography: Comparison with Surgical Results
AJNR Am. J. Neuroradiol., April 1, 2007; 28(4): 716 - 723.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Lell, C. Fellner, U. Baum, T. Hothorn, R. Steiner, W. Lang, W. Bautz, and F.A. Fellner
Evaluation of Carotid Artery Stenosis with Multisection CT and MR Imaging: Influence of Imaging Modality and Postprocessing
AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 104 - 110.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
E. K. Fishman, D. R. Ney, D. G. Heath, F. M. Corl, K. M. Horton, and P. T. Johnson
Volume rendering versus maximum intensity projection in CT angiography: what works best, when, and why.
RadioGraphics, May 1, 2006; 26(3): 905 - 922.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. de Monye, F. Cademartiri, T. T. de Weert, D. A. M. Siepman, D. W. J. Dippel, and A. van Der Lugt
Sixteen-Detector Row CT Angiography of Carotid Arteries: Comparison of Different Volumes of Contrast Material with and without a Bolus Chaser
Radiology, November 1, 2005; 237(2): 555 - 562.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Suzuki, S. Furui, and T. Kaminaga
Accuracy of Automated CT Angiography Measurement of Vascular Diameter in Phantoms: Effect of Size of Display Field of View, Density of Contrast Medium, and Wall Thickness
Am. J. Roentgenol., June 1, 2005; 184(6): 1940 - 1944.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Berg, Z. Zhang, A. Ikonen, P. Sipola, R. Kalviainen, H. Manninen, and R. Vanninen
Multi-Detector Row CT Angiography in the Assessment of Carotid Artery Disease in Symptomatic Patients: Comparison with Rotational Angiography and Digital Subtraction Angiography
AJNR Am. J. Neuroradiol., May 1, 2005; 26(5): 1022 - 1034.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
M. J.W. Koelemay, P. J. Nederkoorn, J. B. Reitsma, and C. B. Majoie
Systematic Review of Computed Tomographic Angiography for Assessment of Carotid Artery Disease
Stroke, October 1, 2004; 35(10): 2306 - 2312.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
T. Wessels, J. U. Harrer, S. Stetter, M. Mull, and C. Klotzsch
Three-Dimensional Assessment of Extracranial Doppler Sonography in Carotid Artery Stenosis Compared With Digital Subtraction Angiography
Stroke, August 1, 2004; 35(8): 1847 - 1851.
[Abstract] [Full Text] [PDF]


Home page
Mayo Clin Proc.Home page
D. W. Dodick, I. Meissner, F. B. Meyer, and H. J. Cloft
Evaluation and Management of Asymptomatic Carotid Artery Stenosis
Mayo Clin. Proc., July 1, 2004; 79(7): 937 - 944.
[Abstract] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Suzuki, S. Furui, T. Kaminaga, and T. Yamauchi
Measurement of Vascular Diameter In Vitro by Automated Software for CT Angiography: Effects of Inner Diameter, Density of Contrast Medium, and Convolution Kernel
Am. J. Roentgenol., May 1, 2004; 182(5): 1313 - 1317.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Rilinger, H Seifarth, R Sokiranski, S Kramer, F Liewald, J Goerich, A Tomzcak, and C E E Nierhoff
Virtual intra-arterial angioscopy (VIA) of the carotid artery based on helical CT data
Br. J. Radiol., November 1, 2003; 76(911): 792 - 797.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R. A. Bucek, M. Reiter, A. Dirisamer, M. Haumer, A. Fritz, E. Minar, and J. Lammer
Three-Dimensional Color Doppler Sonography in Carotid Artery Stenosis
AJNR Am. J. Neuroradiol., August 1, 2003; 24(7): 1294 - 1299.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. Alvarez-Linera, J. Benito-Leon, J. Escribano, J. Campollo, and R. Gesto
Prospective Evaluation of Carotid Artery Stenosis: Elliptic Centric Contrast-Enhanced MR Angiography and Spiral CT Angiography Compared with Digital Subtraction Angiography
AJNR Am. J. Neuroradiol., May 1, 2003; 24(5): 1012 - 1019.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
T. Hirai, Y. Korogi, K. Ono, M. Nagano, K. Maruoka, S. Uemura, and M. Takahashi
Prospective Evaluation of Suspected Stenoocclusive Disease of the Intracranial Artery: Combined MR Angiography and CT Angiography Compared with Digital Subtraction Angiography
AJNR Am. J. Neuroradiol., January 1, 2002; 23(1): 93 - 101.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. A. Addis, K. D. Hopper, T. A. Iyriboz, Y. Liu, S. W. Wise, C. J. Kasales, J. S. Blebea, and D. T. Mauger
CT Angiography: In Vitro Comparison of Five Reconstruction Methods
Am. J. Roentgenol., November 1, 2001; 177(5): 1171 - 1176.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
O. Coskun, M. Hamon, G. Catroux, L. Gosme, P. Courthéoux, and J. Théron
Carotid-cavernous Fistulas: Diagnosis with Spiral CT Angiography
AJNR Am. J. Neuroradiol., April 1, 2000; 21(4): 712 - 716.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
X. Leclerc, J. Y. Gauvrit, and J. P. Pruvo
Usefulness of CT Angiography with Volume Rendering After Carotid Angioplasty and Stenting
Am. J. Roentgenol., March 1, 2000; 174(3): 820 - 822.
[Full Text] [PDF]


Home page
RadiologyHome page
T. Hirai, Y. Korogi, K. Ono, Y. Murata, M. Takahashi, K. Suginohara, and S. Uemura
Maximum Stenosis of Extracranial Internal Carotid Artery: Effect of Luminal Morphology on Stenosis Measurement by Using CT Angiography and Conventional DSA
Radiology, December 1, 2001; 221(3): 802 - 809.
[Abstract] [Full Text] [PDF]