Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gierada, D. S.
Right arrow Articles by Bae, K. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gierada, D. S.
Right arrow Articles by Bae, K. T.
(Radiology. 1999;210:829-834.)
© RSNA, 1999


Experimental Studies

Gadolinium as a CT Contrast Agent: Assessment in a Porcine Model

David S. Gierada, MD1 and Kyongtae T. Bae, MD, PhD1

1 Mallinckrodt Institute of Radiology, Washington University School of Medicine, Barnes-Jewish Hospital, 216 S Kingshighway Blvd, St Louis, MO 63110.

PURPOSE: To investigate the use of gadolinium as a computed tomographic (CT) contrast agent.

MATERIALS AND METHODS: In vitro attenuation measurements of multiple dilutions of gadodiamide and ioversol were compared. In three pigs, 50-mL boluses of undiluted gadodiamide were injected intravenously at 2 mL/sec, and repeated single-level scans were obtained through the lung bases, liver, and kidneys. The doses of 0.8–1.0 mmol of gadolinium per kilogram of body weight were approximately three times the highest doses currently used in patients. Enhancement was determined from attenuation measurements in the aorta, pulmonary arteries, liver, and kidneys.

RESULTS: In vitro, the attenuation of undiluted gadodiamide (3,069 HU) was equivalent to that of ioversol diluted to 106 mg of iodine per milliliter and at equimolar concentrations was 50% greater than that of ioversol. The magnitude of and time to peak enhancement were 141 HU and 27 seconds (n = 3) for the aorta; 168 HU and 21 seconds (n = 3) for the pulmonary arteries; 23 HU and 65 seconds (n = 2) for the liver; and 63 HU and 32 seconds (n = 1) for the kidneys. Time-attenuation curves revealed a useful duration of enhancement of 20–30 seconds for the aorta and pulmonary arteries.

CONCLUSION: Gadolinium produces good vascular enhancement, adequate renal enhancement, and suboptimal hepatic enhancement. Further study is needed to determine the safety of the gadolinium dose required to produce similar enhancement in patients.

Index terms: Computed tomography (CT), contrast enhancement, 60.12112, 60.12116, 761.12112, 761.12116, 81.12112, 81.12116 • Computed tomography (CT), contrast media, 60.12112, 60.12116, 761.12112, 761.12116, 81.12112, 81.12116 • Contrast media, experimental studies • Gadolinium




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. Chicoskie and R. Tello
Gadolinium-Enhanced MDCT Angiography of the Abdomen: Feasibility and Limitations
Am. J. Roentgenol., June 1, 2005; 184(6): 1821 - 1828.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Remy-Jardin, P. Dequiedt, O. Ertzbischoff, I. Tillie-Leblond, J. Bruzzi, A. Duhamel, and J. Remy
Safety and Effectiveness of Gadolinium-enhanced Multi-Detector Row Spiral CT Angiography of the Chest: Preliminary Results in 37 Patients with Contraindications to Iodinated Contrast Agents
Radiology, June 1, 2005; 235(3): 819 - 826.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. W. Henson, R. G. Nogueira, D. J. Covarrubias, R. G. Gonzalez, and M. H. Lev
Gadolinium-Enhanced CT Angiography of the Circle of Willis and Neck
AJNR Am. J. Neuroradiol., June 1, 2004; 25(6): 969 - 972.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
U. Nyman, B. Elmstahl, P. Leander, M. Nilsson, K. Golman, and T. Almen
Are Gadolinium-based Contrast Media Really Safer than Iodinated Media for Digital Subtraction Angiography in Patients with Azotemia?
Radiology, May 1, 2002; 223(2): 311 - 318.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1999 by the Radiological Society of North America.