Technical Developments |
1 Departments of Radiology (E.E.d.L., J.P.M., J.R.B., J.K.S., C.D.T.)
2 Internal Medicine (J.D.T.)
3 Surgery (T.M.D.), University of Virginia Health Sciences Center, Box 170, 1000 Lee St, Charlottesville, VA 22908
4 Magnetic Imaging Technologies, Durham, NC (P.L.B.)
5 Department of Physics, Princeton University, Princeton, NJ (G.D.C.).
Thirty-two magnetic resonance imaging examinations of the lungs were performed in 16 subjects after inhalation of 12 L of helium 3 gas that was laser polarized to 10%25%. The distribution of the gas was generally uniform, with visualization of the fissures in most cases. Ventilation defects were demonstrated in smokers and in a subject with allergies. The technique has potential for evaluating small airways disease.
Index terms: Helium Lung, MR, 60.12143 Magnetic resonance (MR), contrast enhancement, 60.121412, 60.12143 Magnetic resonance (MR), nuclei other than H, 60.121412, 60.12147
This article has been cited by other articles:
![]() |
A. Evans, D. G. McCormack, G. Santyr, and G. Parraga Mapping and quantifying hyperpolarized 3He magnetic resonance imaging apparent diffusion coefficient gradients J Appl Physiol, August 1, 2008; 105(2): 693 - 699. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Lutey, S. S. Lefrak, J. C. Woods, T. Tanoli, J. D. Quirk, A. Bashir, D. A. Yablonskiy, M. S. Conradi, S. T. Bartel, T. K. Pilgram, et al. Hyperpolarized 3He MR Imaging: Physiologic Monitoring Observations and Safety Considerations in 100 Consecutive Subjects Radiology, August 1, 2008; 248(2): 655 - 661. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. A. Altes, M. Eichinger, and M. Puderbach Magnetic Resonance Imaging of the Lung in Cystic Fibrosis Proceedings of the ATS, August 1, 2007; 4(4): 321 - 327. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. E. de Lange, T. A. Altes, J. T. Patrie, J. D. Gaare, J. J. Knake, J. P. Mugler III, and T. A. Platts-Mills Evaluation of Asthma With Hyperpolarized Helium-3 MRI: Correlation With Clinical Severity and Spirometry. Chest, October 1, 2006; 130(4): 1055 - 1062. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. A. Hoffman, B. A. Simon, and G. McLennan State of the Art. A Structural and Functional Assessment of the Lung via Multidetector-Row Computed Tomography: Phenotyping Chronic Obstructive Pulmonary Disease Proceedings of the ATS, August 1, 2006; 3(6): 519 - 532. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. J. R. van Beek and J. M. Wild Hyperpolarized 3-Helium Magnetic Resonance Imaging to Probe Lung Function Proceedings of the ATS, December 1, 2005; 2(6): 528 - 532. [Abstract] [Full Text] [PDF] |
||||
![]() |
C Hill and E J R van Beek MRI of the chest: present and future Imaging, October 1, 2004; 16(1): 61 - 70. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. P. Schuster, A. Kovacs, J. Garbow, and D. Piwnica-Worms Recent Advances in Imaging the Lungs of Intact Small Animals Am. J. Respir. Cell Mol. Biol., February 1, 2004; 30(2): 129 - 138. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Tooker, K. S. Hong, E. L. McKinstry, P. Costello, F. A. Jolesz, and M. S. Albert Distal Airways in Humans: Dynamic Hyperpolarized 3He MR Imaging--Feasibility Radiology, May 1, 2003; 227(2): 575 - 579. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. L. CROXTON, G. G. WEINMANN, R. M. SENIOR, and J. R. HOIDAL Future Research Directions in Chronic Obstructive Pulmonary Disease Am. J. Respir. Crit. Care Med., March 15, 2002; 165(6): 838 - 844. [Full Text] [PDF] |
||||
![]() |
H.U. Kauczor, X.J. Chen, E.J.R. van Beek, and W.G. Schreiber Pulmonary ventilation imaged by magnetic resonance: at the doorstep of clinical application Eur. Respir. J., May 1, 2001; 17(5): 1008 - 1023. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. J. Chen, L. W. Hedlund, H. E. Moller, M. S. Chawla, R. R. Maronpot, and G. A. Johnson Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion PNAS, October 10, 2000; 97(21): 11478 - 11481. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Maki, W. B. Gefter, and A. Alavi Recent Advances in Pulmonary Imaging Chest, November 1, 1999; 116(5): 1388 - 1402. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Salerno, E. E. de Lange, T. A. Altes, J. D. Truwit, J. R. Brookeman, and J. P. Mugler III Emphysema: Hyperpolarized Helium 3 Diffusion MR Imaging of the Lungs Compared with Spirometric Indexes—Initial Experience Radiology, January 1, 2002; 222(1): 252 - 260. [Abstract] [Full Text] [PDF] |
||||