Genitourinary Imaging |
1 From the Department of Radiology, Hospital of the University of Pennsylvania, 3400 Spruce St, Philadelphia, PA 19104. Received April 8, 1998; revision requested June 29; revision received August 26; accepted October 20. Address reprint requests to B.A.B.
PURPOSE: To evaluate a bolus-tracking technique in helical computed tomography (CT) for identifying the onset of the nephrographic phase and to determine the effect of varying the volume and injection rate of contrast material on nephrographic phase onset.
MATERIALS AND METHODS: Seventy-five patients underwent bolus tracking of contrast material followed by helical renal CT. In 50 patients, 150 mL of 60% iodinated contrast material (iohexol or iothalamate meglumine) was injected at either 2 mL/sec (25 patients [group 1]) or 3 mL/sec (25 patients [group 2]). In 25 patients who had previously undergone nephrectomy, 100 mL of 60% iodinated contrast material was injected at 3 mL/sec (group 3). Nephrographic phase onset was determined by visually assessing the transition to a homogeneous nephrogram during a monitoring scan series starting 40 seconds after injection.
RESULTS: Nephrographic phase onset ranged from 60 to 136 seconds (mean, 89 seconds ± 17 [± SD]). Statistically significant differences in mean onset times were observed among groups 1 (103 seconds ± 12), 2 (91 seconds ± 16), and 3 (75 seconds ± 9) (P < .001). Multiple regression analysis showed patient age, contrast material volume, and injection rate to be independent predictors of nephrographic phase onset. Contrast material volume, patient age, and patient weight were independent predictors of the degree of renal enhancement.
CONCLUSION: Nephrographic phase onset is highly dependent on methods of contrast material administration and patient characteristics.
Index terms: Computed tomography (CT), helical, 81.12114, 81.12115, 81.30 Computed tomography (CT), technology, 81.12114, 81.12115, 81.30 Kidney neoplasms, CT, 81.12114, 81.12115 Kidney neoplasms, diagnosis, 81.12114, 81.12115
This article has been cited by other articles:
![]() |
H. Arakawa, T. Kohno, T. Hiki, and Y. Kaji CT Pulmonary Angiography and CT Venography: Factors Associated with Vessel Enhancement Am. J. Roentgenol., July 1, 2007; 189(1): 156 - 161. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, C. Tao, S. Gurel, C. Hong, F. Zhu, T. A. Gebke, M. Milite, and C. F. Hildebolt Effect of Patient Weight and Scanning Duration on Contrast Enhancement during Pulmonary Multidetector CT Angiography Radiology, February 1, 2007; 242(2): 582 - 589. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Birnbaum, D. D. Maki, D. P. Chakraborty, J. E. Jacobs, and J. S. Babb Renal Cyst Pseudoenhancement: Evaluation with an Anthropomorphic Body CT Phantom Radiology, October 1, 2002; 225(1): 83 - 90. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kawashima, C. M. Sandler, R. D. Ernst, E. P. Tamm, S. M. Goldman, and E. K. Fishman CT Evaluation of Renovascular Disease RadioGraphics, September 1, 2000; 20(5): 1321 - 1340. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Maki, B. A. Birnbaum, D. P. Chakraborty, J. E. Jacobs, B. M. Carvalho, and G. T. Herman Renal Cyst Pseudoenhancement: Beam-hardening Effects on CT Numbers Radiology, November 1, 1999; 213(2): 468 - 472. [Abstract] [Full Text] |
||||