Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bakker, J.
Right arrow Articles by Beek, F. J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bakker, J.
Right arrow Articles by Beek, F. J. A.
(Radiology. 1999;211:623-628.)
© RSNA, 1999


Genitourinary Imaging

Renal Volume Measurements: Accuracy and Repeatability of US Compared with That of MR Imaging1

Jeannette Bakker, MD, Marco Olree, MD, Robert Kaatee, MD, Eduard E. de Lange, MD, Karel G. M. Moons, PhD, Jaap J. Beutler, MD and Frederik J. A. Beek, MD

1 From the Departments of Radiology (J.B., M.O., R.K., F.J.A.B.) and Nephrology (J.J.B.), University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands; the Department of Radiology, University of Virginia Health Sciences Center, Charlottesville (E.E.d.L.); and the Julius Centre for Patient Oriented Research, University Utrecht, the Netherlands (K.G.M.M.). Received March 31, 1998; revision requested June 16; revision received August 27; accepted January 20, 1999. Address reprint requests to J.B.

PURPOSE: To determine the accuracy and repeatability of ultrasonography (US) with the ellipsoid formula in calculating the renal volume.

MATERIALS AND METHODS: The renal volumes in 20 volunteers aged 19–51 years were determined by using US with the ellipsoid formula and magnetic resonance (MR) imaging with the voxel-count method by two independent observers for each modality. The observers performed all measurements twice, with an interval between the first and second examinations. The voxel-count method was the reference standard. Repeatability was evaluated by calculating the SD of the difference (method of Bland and Altman).

RESULTS: Renal volume was underestimated with US by 45 mL (25%) on average. A comparable underestimation was found when the ellipsoid formula was applied to MR images. This indicates that the inaccuracy of US renal volume measurements (a) occured because the kidney does not resemble an ellipsoid and (b) was not primarily related to the imaging modality. Intra- and interobserver variations in US volume measurements were poor; the SD of the difference was 21–32 mL. For comparison, the SD of the difference in reference-standard measurements was 5–10 mL.

CONCLUSION: Use of US with the ellipsoid formula is not appropriate for accurate and reproducible calculation of renal volume.

Index terms: Kidney, MR, 81.121416 • Kidney, US, 81.12989, 81.92 • Magnetic resonance (MR), volume measurement, 81.121416 • Ultrasound (US), comparative studies, 81.12989




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
P.-H. Vivier, M. Dolores, I. Gardin, P. Zhang, C. Petitjean, and J.-N. Dacher
In Vitro Assessment of a 3D Segmentation Algorithm Based on the Belief Functions Theory in Calculating Renal Volumes by MRI
Am. J. Roentgenol., September 1, 2008; 191(3): W127 - W134.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S J Gandy, K Armoogum, R S Nicholas, T B McLeay, and J G Houston
A clinical MRI investigation of the relationship between kidney volume measurements and renal function in patients with renovascular disease
Br. J. Radiol., January 1, 2007; 80(949): 12 - 20.
[Abstract] [Full Text] [PDF]


Home page
CJASNHome page
B. Cheong, R. Muthupillai, M. F. Rubin, and S. D. Flamm
Normal Values for Renal Length and Volume as Measured by Magnetic Resonance Imaging
Clin. J. Am. Soc. Nephrol., January 1, 2007; 2(1): 38 - 45.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
G. Zerbini, R. Bonfanti, F. Meschi, E. Bognetti, P. L. Paesano, L. Gianolli, M. Querques, A. Maestroni, G. Calori, A. Del Maschio, et al.
Persistent Renal Hypertrophy and Faster Decline of Glomerular Filtration Rate Precede the Development of Microalbuminuria in Type 1 Diabetes
Diabetes, September 1, 2006; 55(9): 2620 - 2625.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
W. L. Henrich, R. L. Clark, J. P. Kelly, V. M. Buckalew, A. Fenves, W. F. Finn, J. I. Shapiro, P. L. Kimmel, P. Eggers, L. E. Agodoa, et al.
Non-Contrast-Enhanced Computerized Tomography and Analgesic-Related Kidney Disease: Report of the National Analgesic Nephropathy Study
J. Am. Soc. Nephrol., May 1, 2006; 17(5): 1472 - 1480.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. W. Farraher, H. Jara, K. J. Chang, A. Hou, and J. A. Soto
Liver and Spleen Volumetry with Quantitative MR Imaging and Dual-Space Clustering Segmentation
Radiology, October 1, 2005; 237(1): 322 - 328.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. W. van den Dool, M. N. Wasser, J. W. de Fijter, J. Hoekstra, and R. J. van der Geest
Functional Renal Volume: Quantitative Analysis at Gadolinium-enhanced MR Angiography--Feasibility Study in Healthy Potential Kidney Donors
Radiology, July 1, 2005; 236(1): 189 - 195.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. Hermoye, I. Laamari-Azjal, Z. Cao, L. Annet, J. Lerut, B. M. Dawant, and B. E. Van Beers
Liver Segmentation in Living Liver Transplant Donors: Comparison of Semiautomatic and Manual Methods
Radiology, January 1, 2005; 234(1): 171 - 178.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Widjaja, J W Oxtoby, T L Hale, P W Jones, P N Harden, and I W McCall
Ultrasound measured renal length versus low dose CT volume in predicting single kidney glomerular filtration rate
Br. J. Radiol., September 1, 2004; 77(921): 759 - 764.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. S. Teh, E. S. Ang, W. C. Wong, S. B. Tan, A. G. S. Tan, S. M. Chng, M. B. K. Lin, and J. S. K. Goh
MR Renography Using a Dynamic Gradient-Echo Sequence and Low-Dose Gadopentetate Dimeglumine as an Alternative to Radionuclide Renography
Am. J. Roentgenol., August 1, 2003; 181(2): 441 - 450.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1999 by the Radiological Society of North America.