Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heilo, A.
Right arrow Articles by Solheim, O. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heilo, A.
Right arrow Articles by Solheim, O. P.
(Radiology. 1999;211:657-659.)
© RSNA, 1999


Vascular and Interventional Radiology

Malignant Pleural Mesothelioma: US-guided Histologic Core-Needle Biopsy1

Arne Heilo, MD, Anna Elisabeth Stenwig, MD and Øyvin Pleym Solheim, MD

1 From the Departments of Radiology (A.H.), Pathology (A.E.S.), and Oncology (Ø.P.S.), the Norwegian Radium Hospital, Ullernchausséen 70, N-0310 Oslo, Norway. Received October 6, 1997; revision requested December 16; revision received September 10, 1998; accepted December 11. Address reprint requests to A.H.

PURPOSE: To assess the clinical use of ultrasonographically (US) guided core-needle biopsy, performed with a one-hand automatic sampling technique, in the diagnosis of malignant pleural mesothelioma (MPM).

MATERIALS AND METHODS: The authors reviewed the findings in 70 patients with a tentative diagnosis of MPM who underwent US-guided core-needle biopsy at our institution during the past 10 years.

RESULTS: Fifty-two of the 70 patients who underwent automatic high-speed core-needle biopsy at our institution had MPM; 18 had other disorders. The correct diagnosis was made in 56 patients. Twelve of 14 inadequate biopsy specimens were false-negative for MPM. There were no false-positive biopsy results. In the detection of MPM, US-guided core-needle biopsy had a sensitivity of 77%, specificity of 88%, accuracy of 80%, positive predictive value of 100%, and negative predictive value of 57%. There were no serious complications.

CONCLUSION: US-guided core-needle biopsy is highly effective in the diagnosis of MPM. Owing to its simplicity, low cost, and few side effects, it could be the biopsy method of choice for detection of this condition.

Index terms: Biopsies, technology • Mesothelioma, 66.3254 • Pleura, biopsy, 66.1263, 66.12985 • Pleura, neoplasms, 66.3254 • Ultrasound (US), guidance, 66.12985




This article has been cited by other articles:


Home page
RadiologyHome page
P. P. Agarwal, J. M. Seely, F. R. Matzinger, R. M. MacRae, R. A. Peterson, D. E. Maziak, and C. J. Dennie
Pleural Mesothelioma: Sensitivity and Incidence of Needle Track Seeding after Image-guided Biopsy versus Surgical Biopsy
Radiology, November 1, 2006; 241(2): 589 - 594.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
S. Beckh, P. L. Bolcskei, and K.-D. Lessnau
Real-Time Chest Ultrasonography: A Comprehensive Review for the Pulmonologist
Chest, November 1, 2002; 122(5): 1759 - 1773.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
D.-M. Koh, S. Burke, N. Davies, and S. P. G. Padley
Transthoracic US of the Chest: Clinical Uses and Applications
RadioGraphics, January 1, 2002; 22(1): e1 - e1.
[Abstract] [Full Text]


Home page
ChestHome page
R. F. Adams, W. Gray, R. J. O. Davies, and F. V. Gleeson
Percutaneous Image-Guided Cutting Needle Biopsy of the Pleura in the Diagnosis of Malignant Mesothelioma
Chest, December 1, 2001; 120(6): 1798 - 1802.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. F. Adams and F. V. Gleeson
Percutaneous Image-guided Cutting-Needle Biopsy of the Pleura in the Presence of a Suspected Malignant Effusion
Radiology, May 1, 2001; 219(2): 510 - 514.
[Abstract] [Full Text]


Home page
Eur Respir JHome page
B. Ghaye and R.F. Dondelinger
Imaging guided thoracic interventions
Eur. Respir. J., March 1, 2001; 17(3): 507 - 528.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1999 by the Radiological Society of North America.