|
|
||||||||
Gastrointestinal Imaging |
1 From the Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita City, Osaka 565-0871, Japan. From the 1997 RSNA scientific assembly. Received June 17, 1998; revision requested July 30; revision received September 22; accepted December 15. Address reprint requests to T.K. (e-mail: kim@radiol.med.osakau.ac.jp).
PURPOSE: To assess the effects of the intravenous injection rate and dose of contrast material on pancreatic computed tomography (CT).
MATERIALS AND METHODS: A total of 126 patients were divided at random into four groups with different injection rates and doses. Groups 1 and 2 underwent injection of 2 mL per kilogram of body weight of 300 mg of iodine per milliliter of contrast material, and groups 3 and 4 underwent injection of 1.5 mL/kg. The injection rate was 5 mL/sec for groups 1 and 3 and 3 mL/sec for groups 2 and 4. Single-level serial CT scanning was performed at the level of the pancreatic head, and the pancreatic enhancement value was calculated.
RESULTS: The maximum pancreatic enhancement value was 99 HU ± 18 (mean ± SD) for group 1, 90 HU ± 18 for group 2, 86 HU ± 15 for group 3, and 74 HU ± 13 for group 4. There were significant differences in the maximum pancreatic enhancement value between groups 1 and 2 (P = .045), between groups 3 and 4 (P = .001), between groups 1 and 3 (P = .016), and between groups 2 and 4 (P = .001).
CONCLUSION: Both a higher dose and a faster injection rate increased the maximum pancreatic enhancement value.
Index terms: Computed tomography (CT), contrast enhancement, 770.12112, 770.12119 Pancreas, CT, 770.12112, 770.12119 Pancreas, neoplasms, 770.32
This article has been cited by other articles:
![]() |
Y. Yanaga, K. Awai, Y. Nakayama, T. Nakaura, Y. Tamura, M. Hatemura, and Y. Yamashita Pancreas: Patient Body Weight tailored Contrast Material Injection Protocol versus Fixed Dose Protocol at Dynamic CT Radiology, November 1, 2007; 245(2): 475 - 482. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kondo, M. Kanematsu, S. Goshima, T. Miyoshi, Y. Shiratori, M. Onozuka, N. Moriyama, and K. T. Bae MDCT of the Pancreas: Optimizing Scanning Delay with a Bolus-Tracking Technique for Pancreatic, Peripancreatic Vascular, and Hepatic Contrast Enhancement Am. J. Roentgenol., March 1, 2007; 188(3): 751 - 756. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Schueller, W. Schima, C. Schueller-Weidekamm, M. Weber, A. Stift, M. Gnant, and R. Prokesch Multidetector CT of Pancreas: Effects of Contrast Material Flow Rate and Individualized Scan Delay on Enhancement of Pancreas and Tumor Contrast Radiology, November 1, 2006; 241(2): 441 - 448. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Goshima, M. Kanematsu, H. Kondo, R. Yokoyama, T. Miyoshi, H. Kato, Y. Tsuge, Y. Shiratori, H. Hoshi, M. Onozuka, et al. Pancreas: Optimal Scan Delay for Contrast-enhanced Multi-Detector Row CT Radiology, October 1, 2006; 241(1): 167 - 174. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Itoh, M. Ikeda, H. Satake, T. Ota, and T. Ishigaki The effect of patient age on contrast enhancement during CT of the pancreatobiliary region. Am. J. Roentgenol., August 1, 2006; 187(2): 505 - 510. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. T. Johnson and E. K. Fishman IV Contrast Selection for MDCT: Current Thoughts and Practice Am. J. Roentgenol., February 1, 2006; 186(2): 406 - 415. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Imbriaco Reply Am. J. Roentgenol., January 1, 2006; 186(1): 267 - 267. [Full Text] [PDF] |
||||
![]() |
S. M. Erturk Value of the Single-Phase Technique in MDCT Assessment of Pancreatic Tumors Am. J. Roentgenol., January 1, 2006; 186(1): 266 - 267. [Full Text] [PDF] |
||||
![]() |
M. Imbriaco, A. J. Megibow, A. Ragozzino, R. Liuzzi, P. Mainenti, S. Bortone, L. Camera, and M. Salvatore Value of the Single-Phase Technique in MDCT Assessment of Pancreatic Tumors Am. J. Roentgenol., April 1, 2005; 184(4): 1111 - 1117. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Fenchel, T R Fleiter, A J Aschoff, R van Gessel, H-J Brambs, and E M Merkle Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas Br. J. Radiol., October 1, 2004; 77(922): 821 - 830. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Matsuki, H. Kani, F. Tatsugami, S. Yoshikawa, I. Narabayashi, S.-W. Lee, H. Shinohara, E. Nomura, and N. Tanigawa Preoperative Assessment of Vascular Anatomy Around the Stomach by 3D Imaging Using MDCT Before Laparoscopy-Assisted Gastrectomy Am. J. Roentgenol., July 1, 2004; 183(1): 145 - 151. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. L. Bronstein, E. M. Loyer, H. Kaur, H. Choi, C. David, R. A. DuBrow, L. D. Broemeling, K. R. Cleary, and C. Charnsangavej Detection of Small Pancreatic Tumors with Multiphasic Helical CT Am. J. Roentgenol., March 1, 2004; 182(3): 619 - 623. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, K. Hiraishi, and S. Hori Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient Weight Radiology, January 1, 2004; 230(1): 142 - 150. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Fletcher, M. J. Wiersema, M. A. Farrell, J. L. Fidler, L. J. Burgart, T. Koyama, C. D. Johnson, D. H. Stephens, E. M. Ward, and W. S. Harmsen Pancreatic Malignancy: Value of Arterial, Pancreatic, and Hepatic Phase Imaging with Multi-Detector Row CT Radiology, October 1, 2003; 229(1): 81 - 90. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. P. Tamm, P. M. Silverman, C. Charnsangavej, and D. B. Evans Diagnosis, Staging, and Surveillance of Pancreatic Cancer Am. J. Roentgenol., May 1, 2003; 180(5): 1311 - 1323. [Full Text] [PDF] |
||||
![]() |
C. D. Johnson Pancreatic Carcinoma: Developing a Protocol for Multi-Detector Row CT Radiology, July 1, 2001; 220(1): 3 - 4. [Full Text] [PDF] |
||||
![]() |
N. J. McNulty, I. R. Francis, J. F. Platt, R. H. Cohan, M. Korobkin, and A. Gebremariam Multi-Detector Row Helical CT of the Pancreas: Effect of Contrast-enhanced Multiphasic Imaging on Enhancement of the Pancreas, Peripancreatic Vasculature, and Pancreatic Adenocarcinoma Radiology, July 1, 2001; 220(1): 97 - 102. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Yamashita, Y. Komohara, M. Takahashi, M. Uchida, N. Hayabuchi, T. Shimizu, and I. Narabayashi Abdominal Helical CT: Evaluation of Optimal Doses of Intravenous Contrast Material-A Prospective Randomized Study Radiology, September 1, 2000; 216(3): 718 - 723. [Abstract] [Full Text] |
||||