Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kakinuma, R.
Right arrow Articles by Moriyama, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kakinuma, R.
Right arrow Articles by Moriyama, N.
(Radiology. 1999;212:61-66.)
© RSNA, 1999


Thoracic Imaging

Detection Failures in Spiral CT Screening for Lung Cancer: Analysis of CT Findings1

Ryutaro Kakinuma, MD, Hironobu Ohmatsu, MD, Masahiro Kaneko, MD, Kenji Eguchi, MD, Tsuguo Naruke, MD, Kanji Nagai, MD, Yutaka Nishiwaki, MD, Akira Suzuki, MD and Noriyuki Moriyama, MD

1 From the Department of Thoracic Oncology, National Cancer Center Hospital East, 6-5-1 Kashiwa-no-ha, Kashiwa 277-8577, Japan (R.K., H.O., K.N., Y.N.); the Departments of Endoscopy (M.K.), Surgery (T.N.), and Radiology (N.M.), National Cancer Center Hospital, Tokyo, Japan; the National Shikoku Cancer Center Hospital, Matsuyama, Japan (K.E.); and the Japan Anti-Tuberculosis Association, Shizuoka Branch, Japan (A.S.). Received April 3, 1998; revision requested June 5; revision received September 16; accepted December 9. Supported in part by a grant-in-aid for cancer research from the Ministry of Health and Welfare, by a grant for scientific research expenses for health and welfare programs from the Foundation for the Promotion of Cancer Research, and by the New 10-year Strategy for Cancer Control (researching new technology for diagnostic purposes). Address reprint requests to R.K. (e-mail: rkaki@east.ncc.go.jp).

PURPOSE: To clarify the computed tomographic (CT) findings and the progression of minute lung cancers that were missed at initial spiral CT screening but were later detected.

MATERIALS AND METHODS: The findings from seven patients with lung cancer that was missed at the initial spiral CT screening were reviewed. Retrospective CT findings, time to detection, cell type, and pathologic stage were evaluated.

RESULTS: Minute lung cancers missed at early spiral CT included a nodule among the shadows of old tuberculosis (n = 2), a faint nodule with high attenuation in the center of the nodule (n = 1), an increase in attenuation just adjacent to an axial peripheral pulmonary vessel (n = 1) and adjacent to a craniocaudal peripheral pulmonary vessel (n = 1), and a minute faint nodule (n = 2). The time to detection ranged from 6 to 18 months. At pathologic examination, six cancers were stage I, and one was stage II.

CONCLUSION: Minute nodules of lung cancer that are near the threshold of detectability may be missed at spiral CT screening. It is important to examine noncalcified nodules with thin-section CT even when lesions from prior disease, such as those from old tuberculosis, exist and to evaluate the shadows of pulmonary vessels carefully. A follow-up examination is highly recommended.

Index terms: Cancer screening, 60.321 • Diagnostic radiology, observer performance, 60.321 • Lung neoplasms, CT, 60.12115, 60.12118 • Lung neoplasms, diagnosis, 60.3211, 60.3212




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. Girvin and J. P. Ko
Pulmonary Nodules: Detection, Assessment, and CAD
Am. J. Roentgenol., October 1, 2008; 191(4): 1057 - 1069.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
U Shaikh and H. Lewis-Jones
VOMIT victim of medical investigative technology
BMJ, January 5, 2008; 336(7634): 8 - 8.
[Full Text] [PDF]


Home page
RadiologyHome page
C. Wittram, A. C. Waltman, J.-A. O. Shepard, E. Halpern, and L. R. Goodman
Discordance between CT and Angiography in the PIOPED II Study
Radiology, September 1, 2007; 244(3): 883 - 889.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Das, G. Muhlenbruch, A. H. Mahnken, T. G. Flohr, L. Gundel, S. Stanzel, T. Kraus, R. W. Gunther, and J. E. Wildberger
Small Pulmonary Nodules: Effect of Two Computer-aided Detection Systems on Radiologist Performance.
Radiology, November 1, 2006; 241(2): 564 - 571.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Haller, C. Kaiser, P. Buser, G. Bongartz, and J. Bremerich
Coronary artery imaging with contrast-enhanced MDCT: extracardiac findings.
Am. J. Roentgenol., July 1, 2006; 187(1): 105 - 110.
[Abstract] [Full Text] [PDF]


Home page
Infect. Immun.Home page
M. S. Lionakis, J. Lahdenranta, J. Sun, W. Liu, R. E. Lewis, N. D. Albert, R. Pasqualini, W. Arap, and D. P. Kontoyiannis
Development of a Ligand-Directed Approach To Study the Pathogenesis of Invasive Aspergillosis
Infect. Immun., November 1, 2005; 73(11): 7747 - 7758.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Li, H. Arimura, K. Suzuki, J. Shiraishi, Q. Li, H. Abe, R. Engelmann, S. Sone, H. MacMahon, and K. Doi
Computer-aided Detection of Peripheral Lung Cancers Missed at CT: ROC Analyses without and with Localization
Radiology, November 1, 2005; 237(2): 684 - 690.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K. Peldschus, P. Herzog, S. A. Wood, J. I. Cheema, P. Costello, and U. J. Schoepf
Computer-Aided Diagnosis as a Second Reader: Spectrum of Findings in CT Studies of the Chest Interpreted as Normal
Chest, September 1, 2005; 128(3): 1517 - 1523.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. D. Rubin, J. K. Lyo, D. S. Paik, A. J. Sherbondy, L. C. Chow, A. N. Leung, R. Mindelzun, P. K. Schraedley-Desmond, S. E. Zinck, D. P. Naidich, et al.
Pulmonary Nodules on Multi-Detector Row CT Scans: Performance Comparison of Radiologists and Computer-aided Detection
Radiology, January 1, 2005; 234(1): 274 - 283.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Armato III, G. McLennan, M. F. McNitt-Gray, C. R. Meyer, D. Yankelevitz, D. R. Aberle, C. I. Henschke, E. A. Hoffman, E. A. Kazerooni, H. MacMahon, et al.
Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
Radiology, September 1, 2004; 232(3): 739 - 748.
[Abstract] [Full Text] [PDF]


Home page
Jpn J Clin OncolHome page
Y.-H. Yu, W.-H. Hsu, N.-Y. Hsu, T.-Y. Lin, T.-C. Hsia, S.-S. Sun, and C.-H. Kao
The Use of Dual Phase 201Tl SPECT for Differentiating Pulmonary Malignancies from Benign Lesions
Jpn. J. Clin. Oncol., August 1, 2004; 34(8): 445 - 451.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Berlin
Potential Legal Ramifications of Whole-Body CT Screening: Taking a Peek into Pandora's Box
Am. J. Roentgenol., February 1, 2003; 180(2): 317 - 322.
[Full Text] [PDF]


Home page
ChestHome page
P. B. Bach, M. J. Kelley, R. C. Tate, and D. C. McCrory
Screening for Lung Cancer: A Review of the Current Literature
Chest, January 1, 2003; 123(1_suppl): 72S - 82S.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Li, S. Sone, H. Abe, H. MacMahon, S. G. Armato III, and K. Doi
Lung Cancers Missed at Low-Dose Helical CT Screening in a General Population: Comparison of Clinical, Histopathologic, and Imaging Findings
Radiology, December 1, 2002; 225(3): 673 - 683.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Garg, R. L. Keith, T. Byers, K. Kelly, A. L. Kerzner, D. A. Lynch, and Y. E. Miller
Randomized Controlled Trial with Low-Dose Spiral CT for Lung Cancer Screening: Feasibility Study and Preliminary Results
Radiology, November 1, 2002; 225(2): 506 - 510.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. F. Gruden, S. Ouanounou, S. Tigges, S. D. Norris, and T. S. Klausner
Incremental Benefit of Maximum-Intensity-Projection Images on Observer Detection of Small Pulmonary Nodules Revealed by Multidetector CT
Am. J. Roentgenol., July 1, 2002; 179(1): 149 - 157.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
T. Sobue, N. Moriyama, M. Kaneko, M. Kusumoto, T. Kobayashi, R. Tsuchiya, R. Kakinuma, H. Ohmatsu, K. Nagai, H. Nishiyama, et al.
Screening for Lung Cancer With Low-Dose Helical Computed Tomography: Anti-Lung Cancer Association Project
J. Clin. Oncol., February 15, 2002; 20(4): 911 - 920.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
S. J. SWENSEN, J. R. JETT, J. A. SLOAN, D. E. MIDTHUN, T. E. HARTMAN, A.-M. SYKES, G. L. AUGHENBAUGH, F. E. ZINK, S. L. HILLMAN, G. R. NOETZEL, et al.
Screening for Lung Cancer with Low-Dose Spiral Computed Tomography
Am. J. Respir. Crit. Care Med., February 15, 2002; 165(4): 508 - 513.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
C. Schaefer-Prokop and M. Prokop
New imaging techniques in the treatment guidelines for lung cancer
Eur. Respir. J., February 1, 2002; 19(35_suppl): 71S - 83s.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
R.J. van Klaveren, J.D.F. Habbema, J.H. Pedersen, H.J. de Koning, M. Oudkerk, and H.C. Hoogsteden
Lung cancer screening by low-dose spiral computed tomography
Eur. Respir. J., November 1, 2001; 18(5): 857 - 866.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
F. R. Hirsch, W. A. Franklin, A. F. Gazdar, and P. A. Bunn Jr.
Early Detection of Lung Cancer: Clinical Perspectives of Recent Advances in Biology and Radiology
Clin. Cancer Res., January 1, 2001; 7(1): 5 - 22.
[Abstract] [Full Text]


Home page
RadiologyHome page
J. P. Ko and M. Betke
Chest CT: Automated Nodule Detection and Assessment of Change over Time--Preliminary Experience
Radiology, January 1, 2001; 218(1): 267 - 273.
[Abstract] [Full Text]