|
|
||||||||
Neuroradiology |
1 From the Department of Interventional Neuroradiology, Fondation Ophtalmologique Adolphe de Rothschild, 25 rue Manin, 75940 Paris 19, France (C.C., A.W., L.S., M.P., L.C., J.M.) and Department of Neurosurgery, Hopital Beaujon, Clichy, France (A.R.). Received November 12, 1997; revision requested February 16, 1998; revision received July 10; accepted February 12, 1999. Address reprint requests to J.M. (e-mail: moretnri@ fo-rothschild.fr).
PURPOSE: To evaluate the stability of aneurysm occlusion at follow-up angiography after endovascular treatment (EVT) with detachable coils in intracranial berry aneurysms.
MATERIALS AND METHODS: A total of 203 berry aneurysms (<1.5 cm) were treated with EVT. Follow-up angiography at least 3 months later was performed in 169 cases.
RESULTS: Complete occlusion of the aneurysm sac and neck was achieved in 148 aneurysms, subtotal occlusion in 18, and incomplete occlusion in three. Recurrence occurred between 3 and 40 months in 20 (14%) of the 148 totally occluded aneurysms. A second treatment was performed in five cases, was scheduled in one, and failed in one. The small neck remnant increased in size but did not require any retreatment in three cases, and the size of the neck remnant remained stable in 10 cases. Remnant regrowth occurred in six of the 18 subtotally occluded aneurysms. A second treatment was performed in three. Of the 169 cases, last follow-up angiography showed total occlusion in 133 cases, subtotal in 30, and incomplete in six. No rebleeding occurred.
CONCLUSION: A very small recurrence may be observed at the level of the neck of the aneurysm at long-term follow-up angiography despite achieving total occlusion initially with detachable coils.
Index terms: Aneurysm, intracranial, 1728.73 Angiography, 1722.1247 Arteries, therapeutic blockade 1723.1264, 1731.1264, 1733.1264, 174.1264, 175.1264 Brain, hemorrhage, 10.367
This article has been cited by other articles:
![]() |
R.A. Willinsky, J. Peltz, L. da Costa, R. Agid, R.I. Farb, and K.G. terBrugge Clinical and Angiographic Follow-up of Ruptured Intracranial Aneurysms Treated with Endovascular Embolization AJNR Am. J. Neuroradiol., May 1, 2009; 30(5): 1035 - 1040. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Schaafsma, M. E. Sprengers, W. J. van Rooij, M. Sluzewski, C. B.L.M. Majoie, M. J.H. Wermer, and G. J.E. Rinkel Long-Term Recurrent Subarachnoid Hemorrhage After Adequate Coiling Versus Clipping of Ruptured Intracranial Aneurysms Stroke, May 1, 2009; 40(5): 1758 - 1763. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. B. Bederson, E. S. Connolly Jr, H. H. Batjer, R. G. Dacey, J. E. Dion, M. N. Diringer, J. E. Duldner Jr, R. E. Harbaugh, A. B. Patel, and R. H. Rosenwasser Guidelines for the Management of Aneurysmal Subarachnoid Hemorrhage: A Statement for Healthcare Professionals From a Special Writing Group of the Stroke Council, American Heart Association Stroke, March 1, 2009; 40(3): 994 - 1025. [Full Text] [PDF] |
||||
![]() |
A. K. Wakhloo, J. Mandell, M. J. Gounis, C. Brooks, I. Linfante, J. Winer, and J. P. Weaver Stent-Assisted Reconstructive Endovascular Repair of Cranial Fusiform Atherosclerotic and Dissecting Aneurysms: Long-Term Clinical and Angiographic Follow-Up Stroke, December 1, 2008; 39(12): 3288 - 3296. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.E. Sprengers, J. Schaafsma, W.J. van Rooij, M. Sluzewski, G.J.E. Rinkel, B.K. Velthuis, J.C. van Rijn, and C.B. Majoie Stability of Intracranial Aneurysms Adequately Occluded 6 Months after Coiling: A 3T MR Angiography Multicenter Long-Term Follow-Up Study AJNR Am. J. Neuroradiol., October 1, 2008; 29(9): 1768 - 1774. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Anzalone, F. Scomazzoni, M. Cirillo, C. Righi, F. Simionato, M. Cadioli, A. Iadanza, M.A. Kirchin, and G. Scotti Follow-Up of Coiled Cerebral Aneurysms at 3T: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography AJNR Am. J. Neuroradiol., September 1, 2008; 29(8): 1530 - 1536. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Holmin, T. Krings, A. Ozanne, J.-P. Alt, A. Claes, W. Zhao, H. Alvarez, G. Rodesch, and P. Lasjaunias Intradural Saccular Aneurysms Treated by Guglielmi Detachable Bare Coils at a Single Institution Between 1993 and 2005: Clinical Long-Term Follow-Up for a Total of 1810 Patient-Years in Relation to Morphological Treatment Results Stroke, August 1, 2008; 39(8): 2288 - 2297. [Abstract] [Full Text] [PDF] |
||||
![]() |
B.M. Kim, D.I. Kim, Y.S. Shin, E.C. Chung, D.J. Kim, S.H. Suh, S.Y. Kim, S.I. Park, C.S. Choi, and Y.S. Won Clinical Outcome and Ischemic Complication after Treatment of Anterior Choroidal Artery Aneurysm: Comparison between Surgical Clipping and Endovascular Coiling AJNR Am. J. Neuroradiol., February 1, 2008; 29(2): 286 - 290. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Butteriss, A. Gholkar, D. Mitra, D. Birchall, and V. Jayakrishnan Single-Center Experience of Cerecyte Coils in the Treatment of Intracranial Aneurysms: Initial Experience and Early Follow-Up Results AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 53 - 56. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Pierot, X. Leclerc, A. Bonafe, S. Bracard, and for the French Matrix Registry Investigators Endovascular Treatment of Intracranial Aneurysms with Matrix Detachable Coils: Midterm Anatomic Follow-Up from a Prospective Multicenter Registry AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 57 - 61. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.H. Ding, D. Dai, R. Kadirvel, D.A. Lewis, H.J. Cloft, and D.F. Kallmes Relationship Between Aneurysm Volume and Histologic Healing after Coil Embolization in Elastase-Induced Aneurysms: A Retrospective Study AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 98 - 101. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Ries, S. Siemonsen, G. Thomalla, U. Grzyska, H. Zeumer, and J. Fiehler Long-Term Follow-Up of Cerebral Aneurysms after Endovascular Therapy Prediction and Outcome of Retreatment AJNR Am. J. Neuroradiol., October 1, 2007; 28(9): 1755 - 1761. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Abruzzo, T. Tun, and A. Sambanis Efficient Transmicrocatheter Delivery of Functional Fibroblasts with a Bioengineered Collagen Gel-Platinum Microcoil Complex: Toward the Development of Endovascular Cell Therapy for Cerebral Aneurysms AJNR Am. J. Neuroradiol., September 1, 2007; 28(8): 1586 - 1593. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.K. Wakhloo, M.J. Gounis, J.S. Sandhu, N. Akkawi, A.E. Schenck, and I. Linfante Complex-Shaped Platinum Coils for Brain Aneurysms: Higher Packing Density, Improved Biomechanical Stability, and Midterm Angiographic Outcome AJNR Am. J. Neuroradiol., August 1, 2007; 28(7): 1395 - 1400. [Abstract] [Full Text] [PDF] |
||||
![]() |
R.C. Wallace, J.P. Karis, S. Partovi, and D. Fiorella Noninvasive Imaging of Treated Cerebral Aneurysms, Part I: MR Angiographic Follow-Up of Coiled Aneurysms AJNR Am. J. Neuroradiol., June 1, 2007; 28(6): 1001 - 1008. [Abstract] [Full Text] [PDF] |
||||
![]() |
D.F. Kallmes and H.J. Cloft Ready or Not, Here They Come: Randomized Trials Evaluating New Endovascular Aneurysm Therapies AJNR Am. J. Neuroradiol., May 1, 2007; 28(5): 799 - 803. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Campi, N. Ramzi, A. J. Molyneux, P. E. Summers, R. S.C. Kerr, M. Sneade, J. A. Yarnold, J. Rischmiller, and J. V. Byrne Retreatment of Ruptured Cerebral Aneurysms in Patients Randomized by Coiling or Clipping in the International Subarachnoid Aneurysm Trial (ISAT) Stroke, May 1, 2007; 38(5): 1538 - 1544. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.J. Cloft, T. Kaufmann, and D.F. Kallmes Observer Agreement in the Assessment of Endovascular Aneurysm Therapy and Aneurysm Recurrence AJNR Am. J. Neuroradiol., March 1, 2007; 28(3): 497 - 500. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Mitra, A. Herwadkar, C. Soh, and A. Gholkar Follow-Up of Intracranial Aneurysms Treated with Matrix Detachable Coils: A Single-Center Experience AJNR Am. J. Neuroradiol., February 1, 2007; 28(2): 362 - 367. [Abstract] [Full Text] [PDF] |
||||
![]() |
P.E. Schloesser, R.S. Pakbaz, D.I. Levy, S.G. Imbesi, W.H. Wong, and C.W. Kerber Analysis of Complex Framing Coil Stability in a Wide-Necked Aneurysm Model AJNR Am. J. Neuroradiol., February 1, 2007; 28(2): 387 - 389. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.J. Cloft and for the HEAL Investigators HydroCoil for Endovascular Aneurysm Occlusion (HEAL) Study: 3-6 Month Angiographic Follow-Up Results AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 152 - 154. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Pierot, A. Bonafe, S. Bracard, X. Leclerc, and for the French Matrix Registry Investigators Endovascular treatment of intracranial aneurysms with matrix detachable coils: immediate posttreatment results from a prospective multicenter registry. AJNR Am. J. Neuroradiol., September 1, 2006; 27(8): 1693 - 1699. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Raymond, C. Mounayer, I. Salazkin, A. Metcalfe, G. Gevry, C. Janicki, S. Roorda, and P. Leblanc Safety and Effectiveness of Radioactive Coil Embolization of Aneurysms: Effects of Radiation on Recanalization, Clot Organization, Neointima Formation, and Surrounding Nerves in Experimental Models Stroke, August 1, 2006; 37(8): 2147 - 2152. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Gaba, S. A. Ansari, S. S. Roy, F. A. Marden, M. A.G. Viana, and T. W. Malisch Embolization of Intracranial Aneurysms With Hydrogel-Coated Coils Versus Inert Platinum Coils: Effects on Packing Density, Coil Length and Quantity, Procedure Performance, Cost, Length of Hospital Stay, and Durability of Therapy Stroke, June 1, 2006; 37(6): 1443 - 1450. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-H. Li, B.-L. Gao, C. Fang, B.-X. Gu, Y.-S. Cheng, W. Wang, and G. Scotti Angiographic Follow-Up of Cerebral Aneurysms Treated with Guglielmi Detachable Coils: An Analysis of 162 Cases with 173 Aneurysms. AJNR Am. J. Neuroradiol., May 1, 2006; 27(5): 1107 - 1112. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Pierot, C. Delcourt, F. Bouquigny, D. Breidt, B. Feuillet, O. Lanoix, and S. Gallas Follow-up of intracranial aneurysms selectively treated with coils: Prospective evaluation of contrast-enhanced MR angiography. AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 744 - 749. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.J. Cloft and for the HEAL Investigators HydroCoil for Endovascular Aneurysm Occlusion (HEAL) Study: Periprocedural Results. AJNR Am. J. Neuroradiol., February 1, 2006; 27(2): 289 - 292. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Costalat, E. Lebars, L. Sarry, A. Defasque, E. Barbotte, H. Brunel, G. Bourbotte, and A. Bonafe In Vitro Evaluation of 2D-Digital Subtraction Angiography versus 3D-Time-of-Flight in Assessment of Intracranial Cerebral Aneurysm Filling after Endovascular Therapy AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 177 - 184. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. L. Turner, J. N. P. Higgins, A. Gholkar, A. D. Mendelow, A. J. Molyneux, R. S.C. Kerr, S. Chawda, and P. J. Kirkpatrick Intracranial Aneurysms Treated With Endovascular Coils: Detection of Recurrences Using Unenhanced and Contrast-Enhanced Transcranial Color-Coded Duplex Sonography Stroke, December 1, 2005; 36(12): 2654 - 2659. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Iijima, M. Piotin, C. Mounayer, L. Spelle, A. Weill, and J. Moret Endovascular Treatment with Coils of 149 Middle Cerebral Artery Berry Aneurysms Radiology, November 1, 2005; 237(2): 611 - 619. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Goddard, C. J. Moran, D. T. Cross III, and C. P. Derdeyn Absent Relationship between the Coil-Embolization Ratio in Small Aneurysms Treated with a Single Detachable Coil and Outcomes AJNR Am. J. Neuroradiol., September 1, 2005; 26(8): 1916 - 1920. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Linfante, N. M. Akkawi, A. Perlow, V. Andreone, and A. K. Wakhloo Polyglycolide/Polylactide-Coated Platinum Coils for Patients With Ruptured and Unruptured Cerebral Aneurysms: A Single-Center Experience Stroke, September 1, 2005; 36(9): 1948 - 1953. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Gallas, A. Pasco, J.-P. Cottier, J. Gabrillargues, J. Drouineau, C. Cognard, and D. Herbreteau A Multicenter Study of 705 Ruptured Intracranial Aneurysms Treated with Guglielmi Detachable Coils AJNR Am. J. Neuroradiol., August 1, 2005; 26(7): 1723 - 1731. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Lubicz, X. Leclerc, J.-Y. Gauvrit, J.-P. Lejeune, and J.-P. Pruvo Three-Dimensional Packing with Complex Orbit Coils for the Endovascular Treatment of Intracranial Aneurysms AJNR Am. J. Neuroradiol., June 1, 2005; 26(6): 1342 - 1348. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. B. L. M. Majoie, M. E. Sprengers, W. J. J. van Rooij, C. Lavini, M. Sluzewski, J. C. van Rijn, and G. J. den Heeten MR Angiography at 3T versus Digital Subtraction Angiography in the Follow-up of Intracranial Aneurysms Treated with Detachable Coils AJNR Am. J. Neuroradiol., June 1, 2005; 26(6): 1349 - 1356. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. T. Walker, J. Tsai, T. Parish, B. Tzung, A. Shaibani, E. Krupinski, and E. J. Russell MR Angiographic Evaluation of Platinum Coil Packs at 1.5T and 3T: An In Vitro Assessment of Artifact Production: Technical Note AJNR Am. J. Neuroradiol., April 1, 2005; 26(4): 848 - 853. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-Y. Gauvrit, X. Leclerc, M. Pernodet, B. Lubicz, J.-P. Lejeune, D. Leys, and J.-P. Pruvo Intracranial Aneurysms Treated with Guglielmi Detachable Coils: Usefulness of 6-Month Imaging Follow-Up with Contrast-Enhanced MR Angiography AJNR Am. J. Neuroradiol., March 1, 2005; 26(3): 515 - 521. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Slob, M. Sluzewski, W. J. van Rooij, G. Roks, and G. J. E. Rinkel Additional Coiling of Previously Coiled Cerebral Aneurysms: Clinical and Angiographic Results AJNR Am. J. Neuroradiol., September 1, 2004; 25(8): 1373 - 1376. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Levesque, F. Gauthier, J. Raymond, and G. Leclerc 32P-Oligodeoxynucleotide-Coated Coils to Prevent Arterial Recanalization after Embolization AJNR Am. J. Neuroradiol., June 1, 2004; 25(6): 1062 - 1066. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Brown Jr. and D. G. Piepgras Screening for intracranial aneurysms after subarachnoid hemorrhage: Do our patients benefit? Neurology, February 10, 2004; 62(3): 354 - 356. [Full Text] [PDF] |
||||
![]() |
M. J.H. Wermer, E. Buskens, I. C. van der Schaaf, P. M.M. Bossuyt, and G. J.E. Rinkel Yield of screening for new aneurysms after treatment for subarachnoid hemorrhage Neurology, February 10, 2004; 62(3): 369 - 375. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-N. Vallee, L. Pierot, A. Bonafe, F. Turjman, P. Flandroy, J. Berge, G. Rodesch, and S. Bracard Endovascular Treatment of Intracranial Wide-Necked Aneurysms Using Three-Dimensional Coils: Predictors of Immediate Anatomic and Clinical Results AJNR Am. J. Neuroradiol., February 1, 2004; 25(2): 298 - 306. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. J. Cloft and D. F. Kallmes Aneurysm Packing with HydroCoil Embolic System versus Platinum Coils: Initial Clinical Experience AJNR Am. J. Neuroradiol., January 1, 2004; 25(1): 60 - 62. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Raymond, D. Roy, P. Leblanc, S. Roorda, C. Janicki, L. Normandeau, F. Morel, G. Gevry, J.-P. Bahary, M. Chagnon, et al. Endovascular Treatment of Intracranial Aneurysms With Radioactive Coils: Initial Clinical Experience Stroke, December 1, 2003; 34(12): 2801 - 2806. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Raymond, I. Salazkin, A. Metcalfe, F. Guilbert, A. Weill, and D. Roy High-Concentration Ethylene-Vinyl Alcohol Copolymer and Endovascular Treatment of Experimental Aneurysms: Feasibility of Embolization without Protection Devices at the Neck AJNR Am. J. Neuroradiol., October 1, 2003; 24(9): 1778 - 1784. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-P. Cottier, A. Bleuzen-Couthon, S. Gallas, C. B. Vinikoff-Sonier, P. Bertrand, F. Domengie, L. Barantin, and D. Herbreteau Intracranial Aneurysms Treated with Guglielmi Detachable Coils: Is Contrast Material Necessary in the Follow-up with 3D Time-of-Flight MR Angiography? AJNR Am. J. Neuroradiol., October 1, 2003; 24(9): 1797 - 1803. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. P. Broadbent, C. J. Moran, D. T. Cross III, and C. P. Derdeyn Management of Neuroform Stent Dislodgement and Misplacement AJNR Am. J. Neuroradiol., October 1, 2003; 24(9): 1819 - 1822. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Wanke, A. Doerfler, B. Schoch, D. Stolke, and M. Forsting Treatment of Wide-Necked Intracranial Aneurysms with a Self-Expanding Stent System: Initial Clinical Experience AJNR Am. J. Neuroradiol., June 1, 2003; 24(6): 1192 - 1199. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sluzewski, W. J. van Rooij, G. J. E. Rinkel, and D. Wijnalda Endovascular Treatment of Ruptured Intracranial Aneurysms with Detachable Coils: Long-term Clinical and Serial Angiographic Results Radiology, June 1, 2003; 227(3): 720 - 724. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Raymond, F. Guilbert, A. Weill, S. A. Georganos, L. Juravsky, A. Lambert, J. Lamoureux, M. Chagnon, and D. Roy Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable Coils Stroke, June 1, 2003; 34(6): 1398 - 1403. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Han, O-K. Kwon, C. J. Yoon, B. J. Kwon, S. H. Cha, and K.-H. Chang Gas Generation and Clot Formation during Electrolytic Detachment of Guglielmi Detachable Coils: In Vitro Observations and Animal Experiment AJNR Am. J. Neuroradiol., March 1, 2003; 24(3): 539 - 544. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. H. Fujiwara and D. F. Kallmes Healing Response in Elastase-Induced Rabbit Aneurysms after Embolization with a New Platinum Coil System AJNR Am. J. Neuroradiol., August 1, 2002; 23(7): 1137 - 1144. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kiyosue, S. Tanoue, M. Okahara, Y. Hori, T. Nakamura, H. Nagatomi, and H. Mori Anatomic Features Predictive of Complete Aneurysm Occlusion Can Be Determined with Three-Dimensional Digital Subtraction Angiography AJNR Am. J. Neuroradiol., August 1, 2002; 23(7): 1206 - 1213. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Tamatani, Y. Ito, H. Abe, T. Koike, S. Takeuchi, and R. Tanaka Evaluation of the Stability of Aneurysms after Embolization Using Detachable Coils: Correlation between Stability of Aneurysms and Embolized Volume of Aneurysms AJNR Am. J. Neuroradiol., May 1, 2002; 23(5): 762 - 767. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Abruzzo, H. J. Cloft, M. Marek, G. G. Shengelaia, P. B. Snowhill, S. M. Waldrop, and A. Sambanis Interaction of Vascular Smooth Muscle Cells with Collagen-Impregnated Embolization Coils Studied with a Novel Quantitative in Vitro Model AJNR Am. J. Neuroradiol., April 1, 2002; 23(4): 674 - 681. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Short, N. H. Fujiwara, W. F. Marx, G. A. Helm, H. J. Cloft, and D. F. Kallmes Elastase-Induced Saccular Aneurysms in Rabbits: Comparison of Geometric Features with Those of Human Aneurysms AJNR Am. J. Neuroradiol., November 1, 2001; 22(10): 1833 - 1837. [Abstract] [Full Text] [PDF] |
||||
![]() |
Aneurysm Endovascular Therapy AJNR Am. J. Neuroradiol., September 1, 2001; 22(2007): 4S - 7S. [Full Text] [PDF] |
||||
![]() |
D. Roy, G. Milot, and J. Raymond Endovascular Treatment of Unruptured Aneurysms Stroke, September 1, 2001; 32(9): 1998 - 2004. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Boulin and L. Pierot Follow-up of Intracranial Aneurysms Treated with Detachable Coils: Comparison of Gadolinium-enhanced 3D Time-of-Flight MR Angiography and Digital Subtraction Angiography Radiology, April 1, 2001; 219(1): 108 - 113. [Abstract] [Full Text] |
||||
![]() |
W. F. Marx, H. J. Cloft, G. A. Helm, J. G. Short, H. M. Do, M. E. Jensen, and D. F. Kallmes Endovascular Treatment of Experimental Aneurysms by Use of Biologically Modified Embolic Devices: Coil-mediated Intraaneurysmal Delivery of Fibroblast Tissue Allografts AJNR Am. J. Neuroradiol., February 1, 2001; 22(2): 323 - 333. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-P. Cottier, A. Pasco, S. Gallas, J. Gabrillargues, C. Cognard, J. Drouineau, L. Brunereau, and D. Herbreteau Utility of Balloon-assisted Guglielmi Detachable Coiling in the Treatment of 49 Cerebral Aneurysms: A Retrospective, Multicenter Study AJNR Am. J. Neuroradiol., February 1, 2001; 22(2): 345 - 351. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Koivisto, R. Vanninen, H. Hurskainen, T. Saari, J. Hernesniemi, and M. Vapalahti Outcomes of Early Endovascular Versus Surgical Treatment of Ruptured Cerebral Aneurysms : A Prospective Randomized Study Stroke, October 1, 2000; 31(10): 2369 - 2377. [Abstract] [Full Text] [PDF] |
||||