Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yankelevitz, D. F.
Right arrow Articles by Henschke, C. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yankelevitz, D. F.
Right arrow Articles by Henschke, C. I.
(Radiology. 1999;212:561-566.)
© RSNA, 1999


Thoracic Imaging

Small Pulmonary Nodules: Evaluation with Repeat CT-Preliminary Experience1

David F. Yankelevitz, MD, Rajiv Gupta, PhD, Binsheng Zhao, DSc and Claudia I. Henschke, PhD, MD

1 From the Department of Radiology, the New York Hospital–Cornell University Medical Center, 525 E 68th St, New York, NY 10021. Received March 19, 1998; revision requested May 19; final revision received October 25; accepted March 16, 1999. Supported in part by National Institutes of Health grant R01-CA-63393 and General Electric Corporate Research and Development. Address reprint requests to D.F.Y. (e-mail: dyankele@mail.med.cornell.edu).

PURPOSE: To assess the use of early repeat computed tomography (CT) of solitary pulmonary nodules to determine nodule growth.

MATERIALS AND METHODS: The authors performed repeat CT of nodule phantoms to assess the accuracy of their measurement technique. They then used this technique to assess nodule growth (nine malignant, six benign) in 15 patients (nine men, six women; age range, 60–79 years; average age, 66 years) who underwent repeat CT as part of their routine clinical protocol. The final diagnosis was established with surgical resection or follow-up for more than 2 years after an indeterminate biopsy.

RESULTS: Results of phantom experiments revealed that the method used to determine area change is sensitive enough to help detect nodule growth if one pixel is added around the entire circumference of a nodule. With use of standard exponential growth curves and known tumor growth rates, malignant growth could be detected in vivo within 30 days. All 15 in vivo nodules were correctly classified with early repeat CT.

CONCLUSION: Preliminary experience with early repeat CT suggests that a single repeat CT scan obtained 30 days after the first scan can depict growth in most malignant tumors as small as 5 mm.

Index terms: Lung neoplasms, CT, 60.12118 • Lung neoplasms, diagnosis, 60.31, 60.32




This article has been cited by other articles:


Home page
RadiologyHome page
Y. Wang, R. J. van Klaveren, H. J. van der Zaag-Loonen, G. H. de Bock, H. A. Gietema, D. M. Xu, A. L. M. Leusveld, H. J. de Koning, E. T. Scholten, J. Verschakelen, et al.
Effect of Nodule Characteristics on Variability of Semiautomated Volume Measurements in Pulmonary Nodules Detected in a Lung Cancer Screening Program
Radiology, August 1, 2008; 248(2): 625 - 631.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. G. Ravenel, W. M. Leue, P. J. Nietert, J. V. Miller, K. K. Taylor, and G. A. Silvestri
Pulmonary Nodule Volume: Effects of Reconstruction Parameters on Automated Measurements--A Phantom Study
Radiology, May 1, 2008; 247(2): 400 - 408.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
C. I. Henschke and D. F. Yankelevitz
CT Screening for Lung Cancer: Update 2007
Oncologist, January 1, 2008; 13(1): 65 - 78.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. Honda, T. Johkoh, H. Sumikawa, A. Inoue, N. Tomiyama, N. Mihara, Y. Fujita, M. Tsubamoto, M. Yanagawa, T. Daimon, et al.
Pulmonary Nodules: 3D Volumetric Measurement with Multidetector CT Effect of Intravenous Contrast Medium
Radiology, December 1, 2007; 245(3): 881 - 887.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. K. Kim, M. Allen-Auerbach, J. Goldin, B. J. Fueger, M. Dahlbom, M. Brown, J. Czernin, and C. Schiepers
Accuracy of PET/CT in Characterization of Solitary Pulmonary Lesions
J. Nucl. Med., February 1, 2007; 48(2): 214 - 220.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Jennings, H. T. Winer-Muram, M. Tann, J. Ying, and I. Dowdeswell
Distribution of Stage I Lung Cancer Growth Rates Determined with Serial Volumetric CT Measurements
Radiology, November 1, 2006; 241(2): 554 - 563.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Plathow, M. Schoebinger, C. Fink, H. Hof, J. Debus, H.-P. Meinzer, and H.-U. Kauczor
Quantification of Lung Tumor Volume and Rotation at 3D Dynamic Parallel MR Imaging with View Sharing: Preliminary Results
Radiology, August 1, 2006; 240(2): 537 - 545.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Yuan, P. M. Vos, and P. L. Cooperberg
Computer-Aided Detection in Screening CT for Pulmonary Nodules.
Am. J. Roentgenol., May 1, 2006; 186(5): 1280 - 1287.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Ko, R. Marcus, E. Bomsztyk, J. S. Babb, C. Stefanescu, M. Kaur, D. P. Naidich, and H. Rusinek
Effect of blood vessels on measurement of nodule volume in a chest phantom.
Radiology, April 1, 2006; 239(1): 79 - 85.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Awai, K. Murao, A. Ozawa, Y. Nakayama, T. Nakaura, D. Liu, K. Kawanaka, Y. Funama, S. Morishita, and Y. Yamashita
Pulmonary Nodules: Estimation of Malignancy at Thin-Section Helical CT--Effect of Computer-aided Diagnosis on Performance of Radiologists
Radiology, April 1, 2006; 239(1): 276 - 284.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S Diederich, D Theegarten, G Stamatis, and R Luthen
Solitary pulmonary nodule with growth and contrast enhancement at CT: inflammatory pseudotumour as an unusual benign cause
Br. J. Radiol., January 1, 2006; 79(937): 76 - 78.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. MacMahon, J. H. M. Austin, G. Gamsu, C. J. Herold, J. R. Jett, D. P. Naidich, E. F. Patz Jr, and S. J. Swensen
Guidelines for Management of Small Pulmonary Nodules Detected on CT Scans: A Statement from the Fleischner Society
Radiology, November 1, 2005; 237(2): 395 - 400.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
C. I. Henschke
Computed Tomography Screening for Lung Cancer: Principles and Results
Clin. Cancer Res., July 1, 2005; 11(13): 4984s - 4987s.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. Goo, T. Tongdee, R. Tongdee, K. Yeo, C. F. Hildebolt, and K. T. Bae
Volumetric Measurement of Synthetic Lung Nodules with Multi-Detector Row CT: Effect of Various Image Reconstruction Parameters and Segmentation Thresholds on Measurement Accuracy
Radiology, June 1, 2005; 235(3): 850 - 856.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
J. L. Mulshine
New Developments in Lung Cancer Screening
J. Clin. Oncol., May 10, 2005; 23(14): 3198 - 3202.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. T. Boll, R. C. Gilkeson, T. R. Fleiter, K. A. Blackham, J. L. Duerk, and J. S. Lewin
Volumetric Assessment of Pulmonary Nodules with ECG-Gated MDCT
Am. J. Roentgenol., November 1, 2004; 183(5): 1217 - 1223.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. Nomori, K. Watanabe, T. Ohtsuka, T. Naruke, K. Suemasu, T. Kobayashi, and K. Uno
Fluorine 18-tagged fluorodeoxyglucose positron emission tomographic scanning to predict lymph node metastasis, invasiveness, or both, in clinical T1 N0 M0 lung adenocarcinoma
J. Thorac. Cardiovasc. Surg., September 1, 2004; 128(3): 396 - 401.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Armato III, G. McLennan, M. F. McNitt-Gray, C. R. Meyer, D. Yankelevitz, D. R. Aberle, C. I. Henschke, E. A. Hoffman, E. A. Kazerooni, H. MacMahon, et al.
Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
Radiology, September 1, 2004; 232(3): 739 - 748.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. F. Schaefer, J. Vollmar, F. Schick, R. Vonthein, M. D. Seemann, H. Aebert, R. Dierkesmann, G. Friedel, and C. D. Claussen
Solitary Pulmonary Nodules: Dynamic Contrast-enhanced MR Imaging--Perfusion Differences in Malignant and Benign Lesions
Radiology, August 1, 2004; 232(2): 544 - 553.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Jennings, H. T. Winer-Muram, R. D. Tarver, and M. O. Farber
Lung Tumor Growth: Assessment with CT--Comparison of Diameter and Cross-sectional Area with Volume Measurements
Radiology, June 1, 2004; 231(3): 866 - 871.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. J. Kostis, D. F. Yankelevitz, A. P. Reeves, S. C. Fluture, and C. I. Henschke
Small Pulmonary Nodules: Reproducibility of Three-dimensional Volumetric Measurement and Estimation of Time to Follow-up CT
Radiology, May 1, 2004; 231(2): 446 - 452.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M.-P. Revel, C. Lefort, A. Bissery, M. Bienvenu, L. Aycard, G. Chatellier, and G. Frija
Pulmonary Nodules: Preliminary Experience with Three-dimensional Evaluation
Radiology, May 1, 2004; 231(2): 459 - 466.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. Nomori, T. Ohtsuka, T. Naruke, and K. Suemasu
Histogram analysis of computed tomography numbers of clinical T1 N0 M0 lung adenocarcinoma, with special reference to lymph node metastasis and tumor invasiveness
J. Thorac. Cardiovasc. Surg., November 1, 2003; 126(5): 1584 - 1589.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. T. Winer-Muram, S. G. Jennings, C. A. Meyer, Y. Liang, A. M. Aisen, R. D. Tarver, and R. C. McGarry
Effect of Varying CT Section Width on Volumetric Measurement of Lung Tumors and Application of Compensatory Equations
Radiology, October 1, 2003; 229(1): 184 - 194.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Ko, H. Rusinek, E. L. Jacobs, J. S. Babb, M. Betke, G. McGuinness, and D. P. Naidich
Small Pulmonary Nodules: Volume Measurement at Chest CT--Phantom Study
Radiology, September 1, 2003; 228(3): 864 - 870.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. P. Wisnivesky, A. I. Mushlin, N. Sicherman, and C. Henschke
The Cost-Effectiveness of Low-Dose CT Screening for Lung Cancer: Preliminary Results of Baseline Screening
Chest, August 1, 2003; 124(2): 614 - 621.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
D. Ost, A. M. Fein, and S. H. Feinsilver
The Solitary Pulmonary Nodule
N. Engl. J. Med., June 19, 2003; 348(25): 2535 - 2542.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. Ohno, H. Hatabu, D. Takenaka, T. Higashino, H. Watanabe, C. Ohbayashi, and K. Sugimura
CT-Guided Transthoracic Needle Aspiration Biopsy of Small (<= 20 mm) Solitary Pulmonary Nodules
Am. J. Roentgenol., June 1, 2003; 180(6): 1665 - 1669.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Takashima, S. Sone, F. Li, Y. Maruyama, M. Hasegawa, and M. Kadoya
Indeterminate Solitary Pulmonary Nodules Revealed at Population-Based CT Screening of the Lung: Using First Follow-Up Diagnostic CT to Differentiate Benign and Malignant Lesions
Am. J. Roentgenol., May 1, 2003; 180(5): 1255 - 1263.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Takashima, Y. Maruyama, M. Hasegawa, T. Yamanda, T. Honda, M. Kadoya, and S. Sone
CT Findings and Progression of Small Peripheral Lung Neoplasms Having a Replacement Growth Pattern
Am. J. Roentgenol., March 1, 2003; 180(3): 817 - 826.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. S. Benjamin, E. A. Drucker, T. C. McLoud, and J.-A. O. Shepard
Small Pulmonary Nodules: Detection at Chest CT and Outcome
Radiology, February 1, 2003; 226(2): 489 - 493.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
C.I. Henschke, D.F. Yankelevitz, D.I. McCauley, D.M. Libby, M.W. Pasmantier, and J.P. Smith
Guidelines for the use of spiral computed tomography in screening for lung cancer
Eur. Respir. J., January 1, 2003; 21(39_suppl): 45S - 51s.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Armato III, F. Li, M. L. Giger, H. MacMahon, S. Sone, and K. Doi
Lung Cancer: Performance of Automated Lung Nodule Detection Applied to Cancers Missed in a CT Screening Program
Radiology, December 1, 2002; 225(3): 685 - 692.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. Suzuki, H. Asamura, M. Kusumoto, H. Kondo, and R. Tsuchiya
"Early" peripheral lung cancer: prognostic significance of ground glass opacity on thin-section computed tomographic scan
Ann. Thorac. Surg., November 1, 2002; 74(5): 1635 - 1639.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. Y. Jeong, D. G. Mitchell, and T. Kamishima
Small (<20 mm) Enhancing Hepatic Nodules Seen on Arterial Phase MR Imaging of the Cirrhotic Liver: Clinical Implications
Am. J. Roentgenol., June 1, 2002; 178(6): 1327 - 1334.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. T. Winer-Muram, S. G. Jennings, R. D. Tarver, A. M. Aisen, M. Tann, D. J. Conces, and C. A. Meyer
Volumetric Growth Rate of Stage I Lung Cancer prior to Treatment: Serial CT Scanning
Radiology, June 1, 2002; 223(3): 798 - 805.
[Abstract] [Full Text] [PDF]


Home page
Ann. N. Y. Acad. Sci.Home page
C. I. HENSCHKE, D. F. YANKELEVITZ, D. M. LIBBY, D. McCAULEY, M. PASMANTIER, N. K. ALTORKI, J. P. SMITH, and O. S. MIETTINEN
Early Lung Cancer Action Project: Annual Screening Using Single-Slice Helical CT
Ann. N.Y. Acad. Sci., December 1, 2001; 952(1): 124 - 134.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
R.J. van Klaveren, J.D.F. Habbema, J.H. Pedersen, H.J. de Koning, M. Oudkerk, and H.C. Hoogsteden
Lung cancer screening by low-dose spiral computed tomography
Eur. Respir. J., November 1, 2001; 18(5): 857 - 866.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G.R. Ferretti, I. Bricault, and M. Coulomb
Virtual tools for imaging of the thorax
Eur. Respir. J., August 1, 2001; 18(2): 381 - 392.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
C. I. Henschke, D. I. McCauley, D. F. Yankelevitz, D. P. Naidich, G. McGuinness, O. S. Miettinen, D. Libby, M. Pasmantier, J. Koizumi, N. Altorki, et al.
Early Lung Cancer Action Project: A Summary of the Findings on Baseline Screening
Oncologist, April 1, 2001; 6(2): 147 - 152.
[Abstract] [Full Text]


Home page
RadiologyHome page
J. P. Ko and M. Betke
Chest CT: Automated Nodule Detection and Assessment of Change over Time--Preliminary Experience
Radiology, January 1, 2001; 218(1): 267 - 273.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
P. M. Boiselle, A. Ernst, and D. D. Karp
Lung Cancer Detection in the 21st Century: Potential Contributions and Challenges of Emerging Technologies
Am. J. Roentgenol., November 1, 2000; 175(5): 1215 - 1221.
[Full Text] [PDF]


Home page
RadiologyHome page
D. F. Yankelevitz, A. P. Reeves, W. J. Kostis, B. Zhao, and C. I. Henschke
Small Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT Evaluation
Radiology, October 1, 2000; 217(1): 251 - 256.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
S. J. Swensen
Functional CT: Lung Nodule Evaluation
RadioGraphics, July 1, 2000; 20(4): 1178 - 1181.
[Full Text] [PDF]


Home page
RadiologyHome page
S. Diederich, D. Wormanns, M. Semik, M. Thomas, H. Lenzen, N. Roos, and W. Heindel
Screening for Early Lung Cancer with Low-Dose Spiral CT: Prevalence in 817 Asymptomatic Smokers
Radiology, March 1, 2002; 222(3): 773 - 781.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1999 by the Radiological Society of North America.