1 From the Departments of Radiology (M.C., C.E.B., G.A.T., P.S.D.) and Urology (R.G., A.B.B.), Children's Hospital and Harvard Medical School, 300 Longwood Ave, Boston, MA 02115. Received August 26, 1998; revision requested September 23; final revision received November 23; accepted March 29, 1999. G.A.T. supported in part by Alliance Pharmaceutical, San Diego, Calif, and Acuson, Mountain View, Calif. Address reprint requests to G.A.T. (e-mail: taylor_g@a1.tch.harvard.edu).
PURPOSE: To evaluate contrast agentenhanced harmonic ultrasonographic (US) imaging and Doppler hemodynamics during acute urinary obstruction.
MATERIALS AND METHODS: In 12 piglets, the distal ureter was obstructed for 60 minutes, followed by intravenous injection of furosemide. In six piglets, ureteral pressure was further elevated to mean arterial pressure, and in six other piglets ureteral obstruction was released. Contrast-enhanced harmonic imaging was performed, and interlobar resistive index (RI) and renal blood flow were determined at baseline and during each experimental condition. A bolus injection curve was constructed by plotting mean pixel intensity versus time, and the area under this normalized curve was compared with renal blood flow values.
RESULTS: Ureteral obstruction and high ureteral pressure reduced cortical renal blood flow to 88% and 66%, respectively, of baseline values. Administration of contrast agent resulted in marked homogeneous enhancement of the renal cortex. The area under the curve diminished during ureteral obstruction and correlated well with mean cortical blood flow. RI correlated well with renal perfusion pressure but poorly with changes in renal blood flow.
CONCLUSION: Contrast-enhanced harmonic US imaging depicts changes in renal blood flow during acute obstruction. Interlobar RI is a good predictor of renal perfusion pressure but not of changes in renal blood flow.
Index terms: Kidney, stenosis or obstruction, 81.145, 81.84 Kidney, US, 81.12981, 81.12982, 81.12984, 81.12988 Renal arteries, US, 963.12981, 963.12982, 963.12984, 963.12988, 963.762 Ultrasound (US), Doppler studies, 963.12984 Ultrasound (US), harmonic study Ureter, stenosis or obstruction, 82.145, 82.84
This article has been cited by other articles:
![]() |
S. B. Park, J. K. Kim, and K.-S. Cho Complications of Renal Transplantation: Ultrasonographic Evaluation J. Ultrasound Med., May 1, 2007; 26(5): 615 - 633. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. H. Heine, B. Reichart, C. Ulrich, H. Kohler, and M. Girndt Do ultrasound renal resistance indices reflect systemic rather than renal vascular damage in chronic kidney disease? Nephrol. Dial. Transplant., January 1, 2007; 22(1): 163 - 170. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Kim, H. W. Eun, H. J. Lee, D. E. Goo, and D. L. Choi Clinical Use of Renal Perfusion Imaging by Means of Harmonic Sonography With a Microbubble Contrast Agent in Patients After Renal Transplantation: Preliminary Study J. Ultrasound Med., June 1, 2005; 24(6): 755 - 762. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. Tublin, R. O. Bude, and J. F. Platt The Resistive Index in Renal Doppler Sonography: Where Do We Stand? Am. J. Roentgenol., April 1, 2003; 180(4): 885 - 892. [Full Text] [PDF] |
||||