Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Semelka, R. C.
Right arrow Articles by Mauro, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Semelka, R. C.
Right arrow Articles by Mauro, M. A.
(Radiology. 1999;213:86-91.)
© RSNA, 1999


Gastrointestinal Imaging

Liver Metastases: Comparison of Current MR Techniques and Spiral CT during Arterial Portography for Detection in 20 Surgically Staged Cases1

Richard C. Semelka, MD, William G. Cance, MD, Hani B. Marcos, MD and Matthew A. Mauro, MD

1 From the Departments of Radiology (R.C.S., H.B.M., M.A.M.) and Surgery (W.G.C.), University of North Carolina at Chapel Hill, CB 7510, Chapel Hill, NC 27599-7510. Received September 4, 1998; revision requested October 26; final revision received January 7, 1999; accepted April 28. Address reprint requests to R.C.S. (e-mail: richsem@med.unc.edu).

PURPOSE: To compare spiral computed tomography during arterial portography (CTAP) with current magnetic resonance (MR) imaging, including hepatic arterial–dominant phase, gadolinium-enhanced, spoiled gradient-echo imaging, for the prospective detection of liver metastases in 20 patients who subsequently underwent surgery to confirm findings.

MATERIALS AND METHODS: Twenty patients underwent spiral CTAP and MR imaging within 1 week. Spiral CTAP and MR images were interpreted separately in blinded fashion. All patients subsequently had intraoperative confirmation. Sensitivity, specificity, and positive and negative predictive values were determined for lesion detection and segmental distribution.

RESULTS: CTAP and MR images demonstrated, respectively, 54 and 60 true-positive lesions, six and one false-positive lesions, 15 and 22 true-negative (ie, benign) lesions, and eight and two false-negative lesions. CTAP and MR images demonstrated, respectively, 57 and 62 true-positive segmental involvements, six and one false-positive segmental involvements, 89 and 95 true-negative segmental involvements, and eight and two false-negative segmental involvements. No significant difference in lesion detection was observed.

CONCLUSION: Spiral CTAP and MR imaging were approximately equivalent for lesion detection in patients who were evaluated preoperatively for resection of liver metastases. The lower cost and fewer problems with artifacts may suggest that MR imaging is the preferred modality for preoperative assessment of patients for surgical treatment of liver metastases.

Index terms: Computed tomography (CT), comparative studies • Liver neoplasms, CT, 761.12114, 761.12115 • Liver neoplasms, metastases, 761.33 • Liver neoplasms, MR, 761.121411, 761.121412, 761.121415, 761.12143 • Magnetic resonance (MR), comparative studies • Portography, 95.1242




This article has been cited by other articles:


Home page
RadiologyHome page
J. Schnorr, S. Wagner, C. Abramjuk, R. Drees, T. Schink, E. A. Schellenberger, H. Pilgrimm, B. Hamm, and M. Taupitz
Focal Liver Lesions: SPIO-, Gadolinium-, and Ferucarbotran-enhanced Dynamic T1-weighted and Delayed T2-weighted MR Imaging in Rabbits
Radiology, July 1, 2006; 240(1): 90 - 100.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. P. Hosch, S. M. Schmidt, S. Plaza, C. Dechow, J. Schmidt, S. Ley, G. W. Kauffmann, and J. Hansmann
Comparison of CT during arterial portography and MR during arterial portography in the detection of liver metastases.
Am. J. Roentgenol., June 1, 2006; 186(6): 1502 - 1511.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Ward, P. J. Robinson, J. A. Guthrie, S. Downing, D. Wilson, J. P. A. Lodge, K. R. Prasad, G. J. Toogood, and J. I. Wyatt
Liver Metastases in Candidates for Hepatic Resection: Comparison of Helical CT and Gadolinium- and SPIO-enhanced MR Imaging
Radiology, October 1, 2005; 237(1): 170 - 180.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Bipat, M. S. van Leeuwen, E. F. I. Comans, M. E. J. Pijl, P. M. M. Bossuyt, A. H. Zwinderman, and J. Stoker
Colorectal Liver Metastases: CT, MR Imaging, and PET for Diagnosis--Meta-analysis
Radiology, October 1, 2005; 237(1): 123 - 131.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
P Manoharan and J Ward
MRI in the assessment of focal liver lesions in the non-cirrhotic patient
Imaging, September 1, 2004; 16(4): 338 - 350.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
D. V. Sahani and S. P. Kalva
Imaging the Liver
Oncologist, July 1, 2004; 9(4): 385 - 397.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Filippone, R. Ambrosini, M. Fuschi, T. Marinelli, D. Genovesi, and L. Bonomo
Preoperative T and N Staging of Colorectal Cancer: Accuracy of Contrast-enhanced Multi-Detector Row CT Colonography--Initial Experience
Radiology, April 1, 2004; 231(1): 83 - 90.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M.-J. Kim, J. H. Kim, J.-J. Chung, M. S. Park, J. S. Lim, and Y. T. Oh
Focal Hepatic Lesions: Detection and Characterization with Combination Gadolinium- and Superparamagnetic Iron Oxide-enhanced MR Imaging
Radiology, September 1, 2003; 228(3): 719 - 726.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
I. R. Kamel, M. A. Choti, K. M. Horton, H. J. V. Braga, B. A. Birnbaum, E. K. Fishman, R. E. Thompson, and D. A. Bluemke
Surgically Staged Focal Liver Lesions: Accuracy and Reproducibility of Dual-Phase Helical CT for Detection and Characterization
Radiology, June 1, 2003; 227(3): 752 - 757.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
S. C. Eberhardt, P. H. Choi, A. M. Bach, S. A. Funt, H. E. Felderman, and L. E. Hann
Utility of Sonography for Small Hepatic Lesions Found on Computed Tomography in Patients With Cancer
J. Ultrasound Med., April 1, 2003; 22(4): 335 - 343.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. R. van Erkel, M. E. J. Pijl, A. A. van den Berg-Huysmans, M. N. J. M. Wasser, C. J. H. van de Velde, and J. L. Bloem
Hepatic Metastases in Patients with Colorectal Cancer: Relationship between Size of Metastases, Standard of Reference, and Detection Rates
Radiology, August 1, 2002; 224(2): 404 - 409.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. J. V. Braga, M. A. Choti, V. S. Lee, E. K. Paulson, E. S. Siegelman, and D. A. Bluemke
Liver Lesions: Manganese-enhanced MR and Dual-Phase Helical CT for Preoperative Detection and Characterization—Comparison with Receiver Operating Characteristic Analysis
Radiology, May 1, 2002; 223(2): 525 - 531.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Matsuo, M. Kanematsu, K. Itoh, K. Ito, Y. Maetani, H. Kondo, N. Kako, N. Matsunaga, H. Hoshi, and J. Shiraishi
Detection of Malignant Hepatic Tumors: Comparison of Gadolinium-and Ferumoxide-Enhanced MR Imaging
Am. J. Roentgenol., September 1, 2001; 177(3): 637 - 643.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Itai, T. Irie, and R. C. Semelka
Metastatic Liver Tumor: Circumferential versus Wedge-shaped Perilesional Enhancement and Quantitative Image and Pathologic Correlation Dr Semelka responds:
Radiology, April 1, 2001; 219(1): 298 - 300.
[Full Text]


Home page
RadiologyHome page
C. Valls, E. Andía, A. Sánchez, A. Gumà, J. Figueras, J. Torras, and T. Serrano
Hepatic Metastases from Colorectal Cancer: Preoperative Detection and Assessment of Resectability with Helical CT
Radiology, January 1, 2001; 218(1): 55 - 60.
[Abstract] [Full Text]


Home page
RadiologyHome page
P. Reimer, N. Jähnke, M. Fiebich, W. Schima, F. Deckers, C. Marx, N. Holzknecht, and S. Saini
Hepatic Lesion Detection and Characterization: Value of Nonenhanced MR Imaging, Superparamagnetic Iron Oxide-enhanced MR Imaging, and Spiral CT-ROC Analysis
Radiology, October 1, 2000; 217(1): 152 - 158.
[Abstract] [Full Text]


Home page
RadiologyHome page
C. M. C. Tempany, K. H. Zou, S. G. Silverman, D. L. Brown, A. B. Kurtz, and B. J. McNeil
Staging of Advanced Ovarian Cancer: Comparison of Imaging Modalities-Report from the Radiological Diagnostic Oncology Group
Radiology, June 1, 2000; 215(3): 761 - 767.
[Abstract] [Full Text]