Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Don, S.
Right arrow Articles by McAlister, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Don, S.
Right arrow Articles by McAlister, W. H.
(Radiology. 1999;213:455-460.)
© RSNA, 1999


Experimental Studies

Computed Radiography versus Screen-Film Radiography: Detection of Pulmonary Edema in a Rabbit Model That Simulates Neonatal Pulmonary Infiltrates1

Steven Don, MD, Charles F. Hildebolt, DDS, PhD, Terry L. Sharp, RT(R), Gary D. Shackelford, MD, Debra M. Lau, MD 2, Thomas E. Herman, MD and William H. McAlister, MD

1 From the Mallinckrodt Institute of Technology, St Louis Children's Hospital, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110. Received October 7, 1998; revision requested November 11; revision received January 25, 1999; accepted March 2. S.D. supported in part by a grant from the Society for Pediatric Radiology Research and Education Foundation. Address reprint requests to S.D. (e-mail: don@mirlink.wustl.edu).

PURPOSE: To determine if computed radiography is equivalent to screen-film radiography in depicting pulmonary edema and to determine if radiation exposure can be reduced with computed radiography while maintaining equivalent diagnostic accuracy for pulmonary edema.

MATERIALS AND METHODS: Oleic acid was intravenously injected into three rabbits at each of four doses: 0, 0.02, 0.04, and 0.06 mL/kg. Two hours later, chest computed radiographs and screen-film radiographs were obtained at 60 kVp and 1.1 mAs. Additional computed radiographs were obtained after reducing milliampere seconds or by reducing milliampere seconds and increasing the kilovolt peak, which reduced bone marrow exposure by up to 20%. The presence of pulmonary opacities, "truth," was established by the wet-dry weight ratio and by chest computed tomography (CT). The radiographs were masked and randomized. Four observers rated the images for the presence of parenchymal opacities with a dichotomous score and judged the quality of the radiographs on a scale from 1 (worst) to 6 (best). Cochran Q tests and McNemar tests were used to analyze the differences in paired comparisons. Image quality was evaluated with logistic regression analysis.

RESULTS: There was no significant difference between truth and observer ability to detect opacity for either modality or for any exposure (P > .05). There was no significant difference between computed radiography and screen-film radiography for image quality (P > .05).

CONCLUSION: Computed radiography is equivalent to screen-film radiography in the detection of pulmonary edema. Radiation exposure reduction of 20% can be achieved without affecting pulmonary edema detection or image quality.

Index terms: Computed tomography (CT), comparative studies, 60.1211 • Lung, fluid, 60.711 • Radiography, comparative studies, 60.1211, 60.1215 • Radiography, in infants and children, 60.1215 • Radiography, storage phosphor, 60.1215




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. Don, B. R. Whiting, J. S. Ellinwood, D. H. Foos, K. A. Kronemer, and R. A. Kraus
Neonatal Chest Computed Radiography: Image Processing and Optimal Image Display
Am. J. Roentgenol., April 1, 2007; 188(4): 1138 - 1144.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. S. Kim, J.-G. Im, J. M. Goo, K. H. Lee, Y.-J. Lee, S. H. Kim, and S. Kim
Detection of Pulmonary Edema in Pigs: Storage Phosphor versus Amorphous Selenium-based Flat-Panel-Detector Radiography
Radiology, June 1, 2002; 223(3): 695 - 701.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
J V Cook
Radiation protection and quality assurance in paediatric radiology
Imaging, December 1, 2001; 13(4): 229 - 238.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1999 by the Radiological Society of North America.