Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Samei, E.
Right arrow Articles by Eyler, W. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Samei, E.
Right arrow Articles by Eyler, W. R.
(Radiology. 1999;213:727-734.)
© RSNA, 1999


Thoracic Imaging

Detection of Subtle Lung Nodules: Relative Influence of Quantum and Anatomic Noise on Chest Radiographs1

Ehsan Samei, PhD, Michael J. Flynn, PhD and William R. Eyler, MD

1 From the Department of Diagnostic Radiology, Henry Ford Health System, Detroit, Mich. Received November 23, 1998; revision requested February 11, 1999; revision received March 31; accepted July 1. Address reprint requests to M.J.F., Radiology Research (2F), Henry Ford Health System, 1 Ford Pl, Detroit, MI 48202 (e-mail: mikef@rad.hfh.edu).

PURPOSE: To assess the relative influence of quantum mottle and structured lung patterns (anatomic noise) on the detection of subtle lung nodules on chest radiographs.

MATERIALS AND METHODS: Sixty 8 x 8-cm lung pattern images were extracted from digital chest radiographs in healthy individuals. Sixty quantum mottle images of the same size and quantum noise level were extracted from uniformly exposed digital radiographs. Simulated nodules with various peak contrast-diameter products (CD) that emulated subtle tissue-equivalent lung nodules were numerically superimposed at the center on three-fourths of the images. Printouts were independently viewed and scored by five experienced radiologists. The area under the receiver operating characteristic curve (Az) was estimated as a measure of the detectability of the nodules.

RESULTS: At a fixed observer performance level (eg, Az = 0.8), much smaller and lower-contrast nodules were detected on quantum mottle images (1-mm diameter, CD = 0.01 mm), compared with those on anatomic images (4.5-mm diameter, CD = 0.20 mm). The findings generally agreed with the signal-to-noise ratio calculations based on statistical observer models.

CONCLUSION: The detection of subtle lung nodules on chest radiographs is limited by anatomic noise.

Index terms: Diagnostic radiology, observer performance • Lung neoplasms, diagnosis, 60.1215, 60.31 • Lung, nodule, 60.1215, 60.281 • Radiography, digital, 60.1215 • Receiver operating characteristic (ROC) curve • Thorax, radiography, 60.1215




This article has been cited by other articles:


Home page
RadiologyHome page
J. Vikgren, S. Zachrisson, A. Svalkvist, A. A. Johnsson, M. Boijsen, A. Flinck, S. Kheddache, and M. Bath
Comparison of Chest Tomosynthesis and Chest Radiography for Detection of Pulmonary Nodules: Human Observer Study of Clinical Cases
Radiology, December 1, 2008; 249(3): 1034 - 1041.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. J. Tapiovaara
Review of relationships between physical measurements and user evaluation of image quality
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 244 - 248.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. Samei, S. A. Stebbins, J. T. Dobbins III, and J. Y. Lo
Multiprojection Correlation Imaging for Improved Detection of Pulmonary Nodules
Am. J. Roentgenol., May 1, 2007; 188(5): 1239 - 1245.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Samei, R. S. Saunders Jr, J. A. Baker, and D. M. Delong
Digital Mammography: Effects of Reduced Radiation Dose on Diagnostic Performance
Radiology, May 1, 2007; 243(2): 396 - 404.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. P. McAdams, E. Samei, J. Dobbins III, G. D. Tourassi, and C. E. Ravin
Recent Advances in Chest Radiography
Radiology, December 1, 2006; 241(3): 663 - 683.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, J. P. A. van Delft, and J. Geleijns
Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography.
Radiology, November 1, 2006; 241(2): 392 - 398.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. L. Hoe, E. Samei, D. P. Frush, and D. M. Delong
Simulation of Liver Lesions for Pediatric CT
Radiology, December 21, 2005; (2005) 2381050477.
[Abstract] [Full Text]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, S. Borjesson, S. Kheddache, A. Grahn, M. Ruschin, A. Tingberg, S. Mattsson, and L. G. Mansson
Nodule detection in digital chest radiography: introduction to the RADIUS chest trial
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 85 - 91.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Hakansson, M. Bath, S. Borjesson, S. Kheddache, A. A. Johnsson, and L. G. Mansson
Nodule detection in digital chest radiography: effect of system noise
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 97 - 101.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, S. Borjesson, S. Kheddache, A. Grahn, F. O. Bochud, F. R. Verdun, and L. G. Mansson
Nodule detection in digital chest radiography: part of image background acting as pure noise
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 102 - 108.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Samei, J. T. Dobbins III, J. Y. Lo, and M. P. Tornai
A framework for optimising the radiographic technique in digital X-ray imaging
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 220 - 229.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, J. Hansson, and L. G. Mansson
A conceptual optimisation strategy for radiography in a digital environment
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 230 - 235.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, A. Tingberg, and L. G. Mansson
Method of simulating dose reduction for digital radiographic systems
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 253 - 259.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. Hansson, M. Bath, M. Hakansson, H. Grundin, E. Bjurklint, P. Orvestad, A. Kjellstrom, H. Bostrom, M. Jonsson, K. Jonsson, et al.
An optimisation strategy in a digital environment applied to neonatal chest imaging
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 278 - 285.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
L. G. Mansson, M. Bath, and S. Mattsson
Priorities in optimisation of medical X-ray imaging--a contribution to the debate
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 298 - 302.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D G W Onnasch, A Schemm, and H-H Kramer
Optimization of radiographic parameters for paediatric cardiac angiography
Br. J. Radiol., June 1, 2004; 77(918): 479 - 487.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
S. R. Turner, E. Samei, B. S. Hertzberg, D. M. DeLong, R. Vargas-Voracek, A. Singer, C. H. Maynor, and M. A. Kliewer
Sonography of Fetal Choroid Plexus Cysts: Detection Depends on Cyst Size and Gestational Age
J. Ultrasound Med., November 1, 2003; 22(11): 1219 - 1227.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Samei, M. J. Flynn, E. Peterson, and W. R. Eyler
Subtle Lung Nodules: Influence of Local Anatomic Variations on Detection
Radiology, July 1, 2003; 228(1): 76 - 84.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. T. Dobbins III, E. Samei, H. G. Chotas, R. J. Warp, A. H. Baydush, C. E. Floyd Jr, and C. E. Ravin
Chest Radiography: Optimization of X-ray Spectrum for Cesium Iodide-Amorphous Silicon Flat-Panel Detector
Radiology, January 1, 2003; 226(1): 221 - 230.
[Abstract] [Full Text] [PDF]