Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wang, Y.
Right arrow Articles by Bergman, G. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wang, Y.
Right arrow Articles by Bergman, G. W.
(Radiology. 1999;213:751-758.)
© RSNA, 1999


Cardiac Imaging

Cardiac Motion of Coronary Arteries: Variability in the Rest Period and Implications for Coronary MR Angiography1

Yi Wang, PhD, Erez Vidan, BS and Geoffrey W. Bergman, MD

1 From the Departments of Radiology (Y.W., E.V.) and Medicine (G.W.B.), Joan and Sanford I. Weill Medical College, Cornell University, 1300 York Ave, New York, NY 10021. From the 1998 RSNA scientific assembly. Received September 21, 1998; revision requested November 10; final revision received March 5, 1999; accepted April 29. Supported in part by research grants from the Whitaker Foundation and EPIX Medical. Address reprint requests to Y.W. (e-mail: yiwang@mail.med.cornell.edu).

PURPOSE: To measure the duration of the rest period in the cardiac cycle, a parameter vital to data acquisition in coronary magnetic resonance (MR) angiography.

MATERIALS AND METHODS: Motion of coronary arteries was measured in 13 patients by using breath-hold, biplane, conventional angiography, with frontal and lateral projections of the left and right coronary arteries acquired at 30 frames per second. The time courses of the coordinates of bifurcations of proximal parts of the coronary arteries were measured, from which the rest period (motion < 1 mm in orthogonal axes), velocity, displacement range, motion correlation, and reproducibility from heartbeat to heartbeat were estimated.

RESULTS: Both the motion pattern and the amplitude varied substantially from patient to patient. The rest period varied from 66 to 333 msec (mean, 161 msec) for the left coronary artery and from 66 to 200 msec (mean, 120 msec) for the right coronary artery.

CONCLUSION: The rest period for coronary arteries in the cardiac cycle varies substantially from patient to patient, which may cause quality to be inconsistent in current coronary MR angiography. A cardiac motion image prior to coronary data acquisition (preimage) may be used to estimate the optimal duration and timing in the cardiac cycle for coronary MR angiography.

Index terms: Coronary angiography, 54.1244 • Coronary arteries, MR, 54.12142 • Heart, flow dynamics, 54.12142, 54.1244, 54.761 • Magnetic resonance (MR), artifact, 54.12142




This article has been cited by other articles:


Home page
RadiologyHome page
D. Oncel, G. Oncel, and A. Tastan
Effectiveness of Dual-Source CT Coronary Angiography for the Evaluation of Coronary Artery Disease in Patients with Atrial Fibrillation: Initial Experience
Radiology, December 1, 2007; 245(3): 703 - 711.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Seifarth, S. Wienbeck, M. Pusken, K.-U. Juergens, D. Maintz, C. Vahlhaus, W. Heindel, and R. Fischbach
Optimal Systolic and Diastolic Reconstruction Windows for Coronary CT Angiography Using Dual-Source CT
Am. J. Roentgenol., December 1, 2007; 189(6): 1317 - 1323.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. J. M. Kroft, A. de Roos, and J. Geleijns
Artifacts in ECG-Synchronized MDCT Coronary Angiography
Am. J. Roentgenol., September 1, 2007; 189(3): 581 - 591.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Rispler, Z. Keidar, E. Ghersin, A. Roguin, A. Soil, R. Dragu, D. Litmanovich, A. Frenkel, D. Aronson, A. Engel, et al.
Integrated Single-Photon Emission Computed Tomography and Computed Tomography Coronary Angiography for the Assessment of Hemodynamically Significant Coronary Artery Lesions
J. Am. Coll. Cardiol., March 13, 2007; 49(10): 1059 - 1067.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Ustun, M. Desai, K. Z. Abd-Elmoniem, M. Schar, and M. Stuber
Automated Identification of Minimal Myocardial Motion for Improved Image Quality on MR Angiography at 3 T
Am. J. Roentgenol., March 1, 2007; 188(3): W283 - W290.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. M. Bansmann, A. N. Priest, K. Muellerleile, A. Stork, G. K. Lund, M. G. Kaul, and G. Adam
MRI of the Coronary Vessel Wall at 3 T: Comparison of Radial and Cartesian k-Space Sampling
Am. J. Roentgenol., January 1, 2007; 188(1): 70 - 74.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Jahnke, I. Paetsch, S. Achenbach, B. Schnackenburg, R. Gebker, E. Fleck, and E. Nagel
Coronary MR Imaging: Breath-hold Capability and Patterns, Coronary Artery Rest Periods, and {beta}-Blocker Use
Radiology, April 1, 2006; 239(1): 71 - 78.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Herzog, M. Arning-Erb, S. Zangos, K. Eichler, R. Hammerstingl, S. Dogan, H. Ackermann, and T. J. Vogl
Multi-Detector Row CT Coronary Angiography: Influence of Reconstruction Technique and Heart Rate on Image Quality
Radiology, January 1, 2006; 238(1): 75 - 86.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Katoh, M. Stuber, A. Buecker, R. W. Gunther, and E. Spuentrup
Spin-labeling Coronary MR Angiography with Steady-State Free Precession and Radial k-Space Sampling: Initial Results in Healthy Volunteers
Radiology, September 1, 2005; 236(3): 1047 - 1052.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. P.S. Dunphy, A. Freiman, S. M. Larson, and H. W. Strauss
Association of Vascular 18F-FDG Uptake with Vascular Calcification
J. Nucl. Med., August 1, 2005; 46(8): 1278 - 1284.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Ozgun, A. Hoffmeier, M. Kouwenhoven, R. M. Botnar, M. Stuber, H. H. Scheld, W. J. Manning, W. Heindel, and D. Maintz
Comparison of 3D Segmented Gradient-Echo and Steady-State Free Precession Coronary MRI Sequences in Patients with Coronary Artery Disease
Am. J. Roentgenol., July 1, 2005; 185(1): 103 - 109.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. H. K. Hoffmann, H. Shi, R. Manzke, F. T. Schmid, L. De Vries, M. Grass, H.-J. Brambs, and A. J. Aschoff
Noninvasive Coronary Angiography with 16-Detector Row CT: Effect of Heart Rate
Radiology, January 1, 2005; 234(1): 86 - 97.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. J. Riederer
Coronary Artery MR Angiography: Are We There Yet?
Radiology, May 1, 2004; 231(2): 302 - 304.
[Full Text] [PDF]


Home page
RadiologyHome page
E. Spuentrup, M. Katoh, A. Buecker, W. J. Manning, T. Schaeffter, T.-H. Nguyen, H. P. Kuhl, M. Stuber, R. M. Botnar, and R. W. Gunther
Free-breathing 3D Steady-State Free Precession Coronary MR Angiography with Radial k-Space Sampling: Comparison with Cartesian k-Space Sampling and Cartesian Gradient-Echo Coronary MR Angiography--Pilot Study
Radiology, May 1, 2004; 231(2): 581 - 586.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. R. Van Hoe, K. G. De Meerleer, P. Ph. Leyman, and P. K. Vanhoenacker
Coronary Artery Calcium Scoring Using ECG-Gated Multidetector CT: Effect of Individually Optimized Image-Reconstruction Windows on Image Quality and Measurement Reproducibility
Am. J. Roentgenol., October 1, 2003; 181(4): 1093 - 1100.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. C. Yang, C. H. Meyer, M. Terashima, S. Kaji, M. V. McConnell, A. l Macovski, J. M. Pauly, D. G. Nishimura, and B. S. Hu
Spiral magnetic resonance coronary angiography with rapid real-time localization
J. Am. Coll. Cardiol., April 2, 2003; 41(7): 1134 - 1141.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Bogaert, R. Kuzo, S. Dymarkowski, R. Beckers, J. Piessens, and F. E. Rademakers
Coronary Artery Imaging with Real-time Navigator Three-dimensional Turbo-Field-Echo MR Coronary Angiography: Initial Experience
Radiology, March 1, 2003; 226(3): 707 - 716.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
K Nieman, B J Rensing, R-J M van Geuns, J Vos, P M T Pattynama, G P Krestin, P W Serruys, and P J de Feyter
Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate
Heart, December 1, 2002; 88(5): 470 - 474.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Giesler, U. Baum, D. Ropers, S. Ulzheimer, E. Wenkel, M. Mennicke, W. Bautz, W. A. Kalender, W. G. Daniel, and S. Achenbach
Noninvasive Visualization of Coronary Arteries Using Contrast-Enhanced Multidetector CT: Influence of Heart Rate on Image Quality and Stenosis Detection
Am. J. Roentgenol., October 1, 2002; 179(4): 911 - 916.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Plein, J. P. Ridgway, T. R. Jones, T. N. Bloomer, and M. U. Sivananthan
Coronary Artery Disease: Assessment with a Comprehensive MR Imaging Protocol—Initial Results
Radiology, October 1, 2002; 225(1): 300 - 307.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Wang, R. Watts, I. R. Mitchell, T. D. Nguyen, J. W. Bezanson, G. W. Bergman, and M. R. Prince
Coronary MR Angiography: Selection of Acquisition Window of Minimal Cardiac Motion with Electrocardiography-triggered Navigator Cardiac Motion Prescanning--Initial Results
Radiology, February 1, 2001; 218(2): 580 - 585.
[Abstract] [Full Text]


Home page
RadiologyHome page
Y. Wang, P. A. Winchester, L. Yu, R. Watts, G. Ding, H. M. Lee, and G. W. Bergman
Breath-Hold Three-dimensional Contrast-enhanced Coronary MR Angiography: Motion-matched k-Space Sampling for Reducing Cardiac Motion Effects
Radiology, May 1, 2000; 215(2): 600 - 607.
[Abstract] [Full Text]


Home page
CirculationHome page
E. Spuentrup, A. Ruebben, T. Schaeffter, W. J. Manning, R. W. Gunther, and A. Buecker
Magnetic Resonance-Guided Coronary Artery Stent Placement in a Swine Model
Circulation, February 19, 2002; 105(7): 874 - 879.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1999 by the Radiological Society of North America.