Vascular and Interventional Radiology |
1 From the Department of Radiology (D.F., A.A.B., K.H.) and the Division of Angiography and Interventional Radiology (K.H.), University of Vienna, AKH, Währinger Gürtel 18-20, A-1090, Austria, and the Department of Radiology, Stanford University Medical Center, Stanford, Calif (D.F., G.D.R.). Received February 5, 1999; revision requested April 2; revision received May 3, 1999; accepted August 1. D. F. supported by a "Schrödinger Stipendium" grant by the Austrian Science Fund, Vienna, Austria. Manuscript preparation was supported in part by the Ludwig Boltzmann Institute for Radiological Sciences, Vienna, Austria. Address reprint requests to D.F. (e-mail: dominik.fleischmann@univie.ac.at).
PURPOSE: To compare the uniformity of aortoiliac opacification obtained from uniphasic contrast medium injections versus individualized biphasic injections at computed tomographic (CT) angiography.
MATERIALS AND METHODS: Thirty-two patients with an abdominal aortic aneurysm underwent CT angiography. In 16 patients (group 1), 120 mL of contrast material was administered at a flow rate of 4 mL/sec. In the other 16 patients (group 2), biphasic injection protocols were computed by using mathematic deconvolution of each patient's time-attenuation response to a standardized test injection. Attenuation uniformity was quantified as the "plateau deviation" of enhancement values, which were calculated as the SD of the time-contiguous attenuation values observed during the 30-second scanning period.
RESULTS: Group 2 patients received between 77 and 165 mL (mean, 115 mL) of contrast medium. Initial flow rates ranged from 4.1 to 10.0 mL/sec (mean, 6.8 mL/sec) for the first 46 seconds; continuing flow rates ranged from 2.0 to 4.8 mL/sec (mean, 3.1 mL/sec) for the remaining 2426 seconds. The plateau deviation was significantly smaller in group 2 patients (19 HU) versus group 1 patients (38 HU, P <.001).
CONCLUSION: At CT angiography, tailored biphasic injections led to more uniform aortoiliac enhancement, compared with standard uniphasic injections of contrast medium.
Index terms: Aneurysm, aortic, 98.73, 98.12912, 98.12916 Aorta, CT, 98.73, 98.12912, 98.12916 Arteries, CT, 98.12912, 98.12916 Arteries, iliac, 98.12912, 98.12916 Computed tomography (CT), angiography, 98.73, 98.12912, 98.12916 Computed tomography (CT), contrast enhancement, 98.12912, 98.12916
This article has been cited by other articles:
![]() |
P. H. Lin, C. Bechara, P. Kougias, T. T. Huynh, S. A. LeMaire, and J. S. Coselli Assessment of Aortic Pathology and Peripheral Arterial Disease Using Multidetector Computed Tomographic Angiography Vascular and Endovascular Surgery, December 1, 2009; 42(6): 583 - 598. [Abstract] [PDF] |
||||
![]() |
R. Schernthaner, D. Fleischmann, A. Stadler, M. Schernthaner, J. Lammer, and C. Loewe Value of MDCT Angiography in Developing Treatment Strategies for Critical Limb Ischemia Am. J. Roentgenol., May 1, 2009; 192(5): 1416 - 1424. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Nguyen, A. Platon, K. Shanmuganathan, S. E. Mirvis, C. D. Becker, and P.-A. Poletti Evaluation of a Single-Pass Continuous Whole-Body 16-MDCT Protocol for Patients with Polytrauma Am. J. Roentgenol., January 1, 2009; 192(1): 3 - 10. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Kerl, J. G. Ravenel, S. A. Nguyen, P. Suranyi, C. Thilo, P. Costello, W. Bautz, and U. J. Schoepf Right Heart: Split-Bolus Injection of Diluted Contrast Medium for Visualization at Coronary CT Angiography Radiology, May 1, 2008; 247(2): 356 - 364. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Schernthaner, D. Fleischmann, F. Lomoschitz, A. Stadler, J. Lammer, and C. Loewe Effect of MDCT Angiographic Findings on the Management of Intermittent Claudication Am. J. Roentgenol., November 1, 2007; 189(5): 1215 - 1222. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Burrill, Z. Dabbagh, F. Gollub, and M. Hamady Multidetector computed tomographic angiography of the cardiovascular system Postgrad. Med. J., November 1, 2007; 83(985): 698 - 704. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. G. Vrachliotis, K. G. Bis, A. Haidary, R. Kosuri, M. Balasubramaniam, M. Gallagher, G. Raff, M. Ross, B. O'Neil, and W. O'Neill Atypical Chest Pain: Coronary, Aortic, and Pulmonary Vasculature Enhancement at Biphasic Single-Injection 64-Section CT Angiography Radiology, May 1, 2007; 243(2): 368 - 376. [Abstract] [Full Text] [PDF] |
||||
![]() |
I-C. Tsai, T. Lee, M.-C. Chen, W.-L. Tsai, P.-C. Lin, and W.-C. Liao Homogeneous Enhancement in Pediatric Thoracic CT Aortography Using a Novel and Reproducible Method: Contrast-Covering Time Am. J. Roentgenol., April 1, 2007; 188(4): 1131 - 1137. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. H. Lee, J. M. Goo, H. J. Lee, K. G. Kim, J.-G. Im, and K. T. Bae Determination of Optimal Timing Window for Pulmonary Artery MDCT Angiography Am. J. Roentgenol., February 1, 2007; 188(2): 313 - 317. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Schoellnast, H. A. Deutschmann, A. Berghold, G. A. Fritz, G. J. Schaffler, and M. Tillich MDCT Angiography of the Pulmonary Arteries: Influence of Body Weight, Body Mass Index, and Scan Length on Arterial Enhancement at Different Iodine Flow Rates Am. J. Roentgenol., October 1, 2006; 187(4): 1074 - 1078. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Schueller-Weidekamm, E. Wassermann, H. Redl, M. Prokop, M. Zimpfer, C. Herold, P. Germann, and R. Ullrich Dynamic CT Measurement of Pulmonary Enhancement in Piglets with Experimental Acute Respiratory Distress Syndrome. Radiology, May 1, 2006; 239(2): 398 - 405. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, A. Hatcho, Y. Nakayama, S. Kusunoki, D. Liu, M. Hatemura, Y. Funama, M. Denbo, N. Sato, and Y. Yamashita Simulation of Aortic Peak Enhancement on MDCT Using a Contrast Material Flow Phantom: Feasibility Study Am. J. Roentgenol., February 1, 2006; 186(2): 379 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. de Monye, F. Cademartiri, T. T. de Weert, D. A. M. Siepman, D. W. J. Dippel, and A. van Der Lugt Sixteen-Detector Row CT Angiography of Carotid Arteries: Comparison of Different Volumes of Contrast Material with and without a Bolus Chaser Radiology, November 1, 2005; 237(2): 555 - 562. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Fleischmann and G. D. Rubin Quantification of Intravenously Administered Contrast Medium Transit through the Peripheral Arteries: Implications for CT Angiography Radiology, September 1, 2005; 236(3): 1076 - 1082. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Cademartiri, N. R. Mollet, A. van der Lugt, E. P. McFadden, T. Stijnen, P. J. de Feyter, and G. P. Krestin Intravenous Contrast Material Administration at Helical 16-Detector Row CT Coronary Angiography: Effect of Iodine Concentration on Vascular Attenuation Radiology, August 1, 2005; 236(2): 661 - 665. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Heuschmid, A. Kuettner, S. Schroeder, T. Trabold, A. Feyer, M. D. Seemann, R. Kuzo, C. D. Claussen, and A. F. Kopp ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses Am. J. Roentgenol., May 1, 2005; 184(5): 1413 - 1419. [Abstract] [Full Text] [PDF] |
||||
![]() |
V A Duddalwar Multislice CT angiography: a practical guide to CT angiography in vascular imaging and intervention Br. J. Radiol., December 1, 2004; 77(suppl_1): S27 - S38. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Cademartiri, K. Nieman, A. van der Lugt, R. H. Raaijmakers, N. Mollet, P. M. T. Pattynama, P. J. de Feyter, and G. P. Krestin Intravenous Contrast Material Administration at 16-Detector Row Helical CT Coronary Angiography: Test Bolus versus Bolus-tracking Technique Radiology, December 1, 2004; 233(3): 817 - 823. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. M. Ho, R. C. Nelson, J. Thomas, E. I. Gimenez, and D. M. DeLong Abdominal Aortic Aneurysms at Multi-Detector Row Helical CT: Optimization with Interactive Determination of Scanning Delay and Contrast Medium Dose Radiology, September 1, 2004; 232(3): 854 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
G H Roditi and G Harold Magnetic resonance angiography and computed tomography angiography for peripheral arterial disease Imaging, August 1, 2004; 16(3): 205 - 229. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. J. Schoepf, C. R. Becker, B. M. Ohnesorge, and E. K. Yucel CT of Coronary Artery Disease Radiology, July 1, 2004; 232(1): 18 - 37. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, H. Q. Tran, and J. P. Heiken Uniform Vascular Contrast Enhancement and Reduced Contrast Medium Volume Achieved by Using Exponentially Decelerated Contrast Material Injection Method Radiology, June 1, 2004; 231(3): 732 - 736. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. J. Schoepf and P. Costello CT Angiography for Diagnosis of Pulmonary Embolism: State of the Art Radiology, February 1, 2004; 230(2): 329 - 337. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Ba-Ssalamah, M. Prokop, M. Uffmann, P. Pokieser, B. Teleky, and G. Lechner Dedicated Multidetector CT of the Stomach: Spectrum of Diseases RadioGraphics, May 1, 2003; 23(3): 625 - 644. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Francois, S. M. Shors, R. O. Bonow, and J. P. Finn Analysis of Cardiopulmonary Transit Times at Contrast Material-enhanced MR Imaging in Patients with Heart Disease Radiology, May 1, 2003; 227(2): 447 - 452. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Schoder, F. Cartes-Zumelzu, M. Grabenwoger, M. Cejna, M. Funovics, C. G. Krenn, D. Hutschala, F. Wolf, S. Thurnher, G. Kretschmer, et al. Elective Endovascular Stent-Graft Repair of Atherosclerotic Thoracic Aortic Aneurysms:Clinical Results and Midterm Follow-Up Am. J. Roentgenol., March 1, 2003; 180(3): 709 - 715. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D. Rubin, A. J. Schmidt, L. J. Logan, and M. C. Sofilos Multi-Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience Radiology, October 1, 2001; 221(1): 146 - 158. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Macari, G. M. Israel, P. Berman, M. Lisi, A. J. Tolia, M. Adelman, and A. J. Megibow Infrarenal Abdominal Aortic Aneurysms at Multi-Detector Row CT Angiography: Intravascular Enhancement without a Timing Acquisition Radiology, August 1, 2001; 220(2): 519 - 523. [Abstract] [Full Text] [PDF] |
||||