|
|
||||||||
Experimental Studies |
1 From the Robarts Research Institute, Imaging Research Laboratories, PO Box 5015, 100 Perth Dr, London, Ontario, Canada N6A 5K8 (S.E.C., E.D., A.R.L., B.K.R.); the Department of Medical Biophysics, University of Western Ontario, London, Canada (S.E.C., B.K.R.); and the Schering Contrast Media Research Laboratories, Berlin, Germany (H.J.W.). Received April 2, 1999; revision requested May 21; revision received June 18; accepted August 10. Supported in part by grants from Schering Contrast Media Research Laboratories and the Medical Research Council of Canada (no. MT-14315). Address reprint requests to B.K.R. (brutt@irus.rri.on.ca).
PURPOSE: To evaluate two experimental blood pool agents for potential use in equilibrium phase abdominal magnetic resonance (MR) angiography.
MATERIALS AND METHODS: MR imaging at 0.5 T was performed in 37 rabbits before and after intravenous injection of a gadolinium-based blood pool contrast agent (SH L 643 A), superparamagnetic iron oxide blood pool agent (SH U 555 C), or gadopentetate dimeglumine. T1-weighted fast spoiled gradient-echo images from the renal arteries to below the iliac bifurcation were obtained. The aorta-to-tissue signal differenceto-noise ratio (SDNR) was measured over time.
RESULTS: Both blood pool agents yielded excellent demonstration of the rabbit abdominal aorta. At a dose of 0.1 mmol/kg, both provided a statistically significant increase in aorta-to-tissue SDNR in comparison with that achieved with gadopentetate dimeglumine (200% increase for SH L 643 A, 95% increase for SH U 555 C; P < .05). A 0.1 mmol/kg dose of SH L 643 A provided a 24% increase in SDNR relative to the increase with a 0.37 mmol/kg dose of gadopentetate dimeglumine. Time-dependent enhancement properties of the blood pool agents differed due to differences in elimination method.
CONCLUSION: Both blood pool agents were found to be promising contrast agents for 0.5-T MR angiography; however, their clinical applicability warrants further investigation. The gadolinium-based agent had several advantages over the iron oxide compound, including less T2* dephasing, lack of susceptibility artifacts, and fast renal elimination.
Index terms: Contrast media, comparative studies Contrast media, experimental studies Gadolinium Iron Magnetic resonance (MR), contrast media, 981.12943 Magnetic resonance (MR), vascular studies, 981.129412, 981.12942, 981.12943
This article has been cited by other articles:
![]() |
G. Korosoglou, S. Shah, E.-J. Vonken, W. D. Gilson, M. Schar, L. Tang, D. L. Kraitchman, R. C. Boston, D. E. Sosnovik, R. G. Weiss, et al. Off-Resonance Angiography: A New Method to Depict Vessels--Phantom and Rabbit Studies Radiology, November 1, 2008; 249(2): 501 - 509. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. W. Lee, W. K. Moon, H.-J. Weinmann, S. J. Kim, J. H. Kim, S. H. Park, T. J. Kim, C. J. Yoon, Y. H. Kim, E. Y. Cho, et al. Contrast-enhanced MR Imaging of Postoperative Scars and VX2 Carcinoma in Rabbits: Comparison of Macromolecular Contrast Agent and Gadopentetate Dimeglumine Radiology, October 1, 2003; 229(1): 132 - 139. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Lee, H. W. Goo, S. B. Park, C. H. Lim, G. Gong, J. B. Seo, and T.-H. Lim MR Imaging of Reperfused Myocardial Infarction: Comparison of Necrosis-Specific and Intravascular Contrast Agents in a Cat Model Radiology, March 1, 2003; 226(3): 739 - 747. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L. Gerber, D. A. Bluemke, B. B. Chin, R. C. Boston, A. W. Heldman, J. A. C. Lima, and D. L. Kraitchman Single-Vessel Coronary Artery Stenosis: Myocardial Perfusion Imaging with Gadomer-17 First-Pass MR Imaging in a Swine Model of Comparison with Gadopentetate Dimeglumine Radiology, October 1, 2002; 225(1): 104 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Taupitz, J. Schnorr, S. Wagner, C. Abramjuk, H. Pilgrimm, D. Kivelitz, T. Schink, J. Hansel, G. Laub, H. Hunigen, et al. Coronary MR Angiography: Experimental Results with a Monomer-stabilized Blood Pool Contrast Medium Radiology, January 1, 2002; 222(1): 120 - 126. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Allkemper, C. Bremer, L. Matuszewski, W. Ebert, and P. Reimer Contrast-enhanced Blood-Pool MR Angiography with Optimized Iron Oxides: Effect of Size and Dose on Vascular Contrast Enhancement in Rabbits Radiology, May 1, 2002; 223(2): 432 - 438. [Abstract] [Full Text] [PDF] |
||||