Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weishaupt, D.
Right arrow Articles by Debatin, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weishaupt, D.
Right arrow Articles by Debatin, J. F.
(Radiology. 2000;214:902-907.)
© RSNA, 2000


Technical Developments

Ligating Clips for Three-dimensional MR Angiography at 1.5 T: In Vitro Evaluation1

Dominik Weishaupt, MD, Harald H. Quick, MSc, Daniel Nanz, PhD, Michaela Schmidt, RT, Paolo C. Cassina, MD and Jörg F. Debatin, MD

1 From the Institute of Diagnostic Radiology (D.W., H.H.Q., D.N., M.S., J.F.D.) and the Department of Surgery (P.C.C.), University Hospital Zürich, Switzerland. Received January 20, 1999; revision requested April 5; revision received June 18; accepted August 12. Address reprint requests to J.F.D., Department of Diagnostic Radiology, University Hospital Essen, Hufelandstrasse 55, D-45122 Essen, Germany (e-mail: debatin@uni-essen.de).

Artifact size on three-dimensional (3D) magnetic resonance (MR) angiograms and safety of various vascular clips (15 titanium and three absorbable polydioxanone clips) were assessed. All evaluated clips were completely safe. Biodegradable clips rendered no artifacts; titanium clips were associated with susceptibility effects. Artifact size was dependent on clip size, clip orientation, echo time, and degree of k-space coverage. In the presence of titanium vascular clips, fast 3D MR angiography should be performed with the shortest echo time and full k-space coverage.

Index terms: Magnetic resonance (MR), artifact, 9*.129422 • Magnetic resonance (MR), safety, 9*.12942




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. C. Genson, C. E. Blane, M. A. Helvie, S. A. Waits, and T. L. Chenevert
Effects on Breast MRI of Artifacts Caused by Metallic Tissue Marker Clips
Am. J. Roentgenol., February 1, 2007; 188(2): 372 - 376.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. R. Khalid, V. J. Casillas, B. M. Montalvo, R. Centeno, and J. U. Levi
Using MR Cholangiopancreatography to Evaluate Iatrogenic Bile Duct Injury
Am. J. Roentgenol., December 1, 2001; 177(6): 1347 - 1352.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. V. Pandharipande, V. S. Lee, G. R. Morgan, L. W. Teperman, G. A. Krinsky, N. M. Rofsky, M.-C. Roy, and J. C. Weinreb
Vascular and Extravascular Complications of Liver Transplantation: Comprehensive Evaluation with Three-Dimensional Contrast-Enhanced Volumetric MR Imaging and MR Cholangiopancreatography
Am. J. Roentgenol., November 1, 2001; 177(5): 1101 - 1107.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Bertschinger, P. C. Cassina, J. F. Debatin, and S. G. Ruehm
Surveillance of Peripheral Arterial Bypass Grafts with Three-Dimensional MR Angiography: Comparison with Digital Subtraction Angiography
Am. J. Roentgenol., January 1, 2001; 176(1): 215 - 220.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2000 by the Radiological Society of North America.