Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kanematsu, M.
Right arrow Articles by Moriwaki, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kanematsu, M.
Right arrow Articles by Moriwaki, H.
(Radiology. 2000;215:95-102.)
© RSNA, 2000


Gastrointestinal Imaging

Pancreas and Peripancreatic Vessels: Effect of Imaging Delay on Gadolinium Enhancement at Dynamic Gradient-Recalled-Echo MR Imaging1

Masayuki Kanematsu, MD, Yoshimune Shiratori, MD, Hiroaki Hoshi, MD, Hiroshi Kondo, MD, Masayuki Matsuo, MD and Hisataka Moriwaki, MD

1 From the Department of Radiology (M.K., H.H., H.K., M.M.) and the First Department of Internal Medicine (Y.S., H.M.), Gifu University School of Medicine, 40 Tsukasamachi, Gifu 500-8705, Japan. Received April 20, 1999; revision requested June 29; revision received August 5; accepted August 13. Address reprint requests to M.K. (e-mail: masa-gif@umin.ac.jp).

PURPOSE: To investigate the effect of imaging delay on gadolinium enhancement of the pancreas and peripancreatic vessels at dynamic gradient-recalled-echo magnetic resonance (MR) imaging of the pancreas.

MATERIALS AND METHODS: Dynamic MR images were obtained after intravenous bolus injection of gadopentetate dimeglumine in 75 patients with no pancreatic malignancies. Test-bolus imaging was performed to determine aortic transit time in individual patients. Patients were randomly assigned so that the middle of k space was acquired at 5, 15, 25, 35, or 45 seconds after arrival of contrast material in the abdominal aorta. Mean signal intensities of pancreas, liver, and peripancreatic vessels were measured, and images were qualitatively assessed by two radiologists.

RESULTS: The best pancreatic enhancement occurred at a delay of 15 seconds (P < .05). The best enhancement of the liver and peripancreatic vessels occurred at 25 seconds or later (P < .05). Qualitatively, the best images of the pancreas were obtained at 15 seconds, and the best images of the liver and peripancreatic vessels were obtained at 25 seconds or later.

CONCLUSION: Biphasic imaging at 15 and 45 seconds or later after arrival of contrast material in the abdominal aorta is a practical method for acquisition of high-quality dynamic gradient-recalled-echo MR images of the pancreas.

Index terms: Liver, MR, 761.121412, 761.121414, 761.121415, 761.12143 • Pancreas, blood supply, 770.92, 95.92 • Pancreas, cysts, 770.312 • Pancreas, fat, 770.299 • Pancreas, MR, 770.121412, 770.121414, 770.121415, 770.12143 • Pancreas, neoplasms, 770.312, 770.32 • Pancreas, surgery, 770.45 • Pancreatitis, 770.291, 770.458




This article has been cited by other articles:


Home page
Diabetes CareHome page
E. Faglia, G. Clerici, J. Clerissi, L. Gabrielli, S. Losa, M. Mantero, M. Caminiti, V. Curci, A. Quarantiello, T. Luppattelli, et al.
Long-Term Prognosis of Diabetic Patients With Critical Limb Ischemia: A population-based cohort study
Diabetes Care, May 1, 2009; 32(5): 822 - 827.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. L. Chu, B. N. Joe, A. C. A. Westphalen, E. M. Webb, F. V. Coakley, and B. M. Yeh
Patient-specific Time to Peak Abdominal Organ Enhancement Varies with Time to Peak Aortic Enhancement at MR Imaging
Radiology, December 1, 2007; 245(3): 779 - 787.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Kanematsu, R. C. Semelka, M. Matsuo, H. Kondo, M. Enya, S. Goshima, N. Moriyama, and H. Hoshi
Gadolinium-enhanced MR Imaging of the Liver: Optimizing Imaging Delay for Hepatic Arterial and Portal Venous Phases—A Prospective Randomized Study in Patients with Chronic Liver Damage
Radiology, November 1, 2002; 225(2): 407 - 415.
[Abstract] [Full Text] [PDF]