Vascular and Interventional Radiology |
1 From the Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305-5105. Received June 15, 1999; revision requested August 3; revision received August 17; accepted September 14. Supported by National Institutes of Health grant R01HL58915. Address correspondence to G.D.R. (e-mail: grubin @stanford.edu).
PURPOSE: To compare single- versus four-channel helical computed tomographic (CT) aortography.
MATERIALS AND METHODS: Forty-eight patients with aortic aneurysm or dissection underwent four- and one-channel CT angiography. Scan pairs covered the thoracic inlet to the diaphragm (n = 10) and supraceliac abdominal aorta (n = 19) or thoracic inlet (n = 19) to the femoral arterial bifurcations. For four-channel CT, nominal section thickness and pitch were 2.5 mm and 6.0, respectively, and for one-channel CT, 3.0 mm and 2.0 to the infrarenal aorta and 5.0 mm and 2.0 to the femoral arteries. Effective section thickness, scanning duration, scanning coverage, dose of iodinated contrast material, and mean aortoiliac attenuation were compared. Data were summarized as speed (coverage/duration), scanning efficiency (speed/section thickness), and contrast efficiency (mean aortic attenuation/dose of contrast material).
RESULTS: At four- versus one-channel CT, CT angiography was 2.6 times faster, scanning efficiency was 4.1 times greater, contrast efficiency was 2.5 times greater, dose of contrast material was reduced (mean, 57%; 97 vs 232 mL) without a significant change in aortic enhancement, and sections were thinner (mean, 40%; 3.2 vs 5.3 mm) despite a 59% shorter scanning duration (22 vs 56 seconds).
CONCLUSION: Substantially reduced doses of contrast medium, shorter scanning durations, and narrower effective sections result with four- versus one-channel CT aortography. No advantages of one-channel CT aortography were demonstrated.
Index terms: Aneurysm, aorta, 94.73, 98.73, Aorta, CT, 94.12912, 94.12914, 94.12915, 94.12916, 98.12912, 98.12914, 98.12915, 98.12916 Aorta, dissection, 94.74, 98.74 Computed tomography (CT), angiography, 94.12916, 98.12916 Computed tomography (CT), comparative studies Computed tomography (CT), helical, 94.12915, 98.12915 Computed tomography (CT), technology
This article has been cited by other articles:
![]() |
P. H. Lin, C. Bechara, P. Kougias, T. T. Huynh, S. A. LeMaire, and J. S. Coselli Assessment of Aortic Pathology and Peripheral Arterial Disease Using Multidetector Computed Tomographic Angiography Vascular and Endovascular Surgery, December 1, 2009; 42(6): 583 - 598. [Abstract] [PDF] |
||||
![]() |
D.Y. Yoon, S.K. Chang, C.S. Choi, W.-K. Kim, and J.-H. Lee Multidetector Row CT Angiography in Spontaneous Lobar Intracerebral Hemorrhage: A Prospective Comparison with Conventional Angiography AJNR Am. J. Neuroradiol., May 1, 2009; 30(5): 962 - 967. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Schernthaner, D. Fleischmann, A. Stadler, M. Schernthaner, J. Lammer, and C. Loewe Value of MDCT Angiography in Developing Treatment Strategies for Critical Limb Ischemia Am. J. Roentgenol., May 1, 2009; 192(5): 1416 - 1424. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Josephs, H. A. Rowley, G. D. Rubin, and for Writing Group 3 Atherosclerotic Peripheral Vascular Disease Symposium II: Vascular Magnetic Resonance and Computed Tomographic Imaging Circulation, December 16, 2008; 118(25): 2837 - 2844. [Full Text] [PDF] |
||||
![]() |
R. Schernthaner, D. Fleischmann, F. Lomoschitz, A. Stadler, J. Lammer, and C. Loewe Effect of MDCT Angiographic Findings on the Management of Intermittent Claudication Am. J. Roentgenol., November 1, 2007; 189(5): 1215 - 1222. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Burrill, Z. Dabbagh, F. Gollub, and M. Hamady Multidetector computed tomographic angiography of the cardiovascular system Postgrad. Med. J., November 1, 2007; 83(985): 698 - 704. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. W. Stavropoulos and S. R. Charagundla Imaging Techniques for Detection and Management of Endoleaks after Endovascular Aortic Aneurysm Repair Radiology, June 1, 2007; 243(3): 641 - 655. [Abstract] [Full Text] [PDF] |
||||
![]() |
D.Y. Yoon, K.J. Lim, C.S. Choi, B.M. Cho, S.M. Oh, and S.K. Chang Detection and Characterization of Intracranial Aneurysms with 16-Channel Multidetector Row CT Angiography: A Prospective Comparison of Volume-Rendered Images and Digital Subtraction Angiography AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 60 - 67. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Nakayama, K. Awai, Y. Funama, D. Liu, T. Nakaura, Y. Tamura, and Y. Yamashita Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. Am. J. Roentgenol., November 1, 2006; 187(5): W490 - W497. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Ouwendijk, M. C. J. M. Kock, L. C. van Dijk, M. R. H. M. van Sambeek, T. Stijnen, and M. G. M. Hunink Vessel Wall Calcifications at Multi-Detector Row CT Angiography in Patients with Peripheral Arterial Disease: Effect on Clinical Utility and Clinical Predictors Radiology, November 1, 2006; 241(2): 603 - 608. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kubo, E. Tadamura, M. Yamamuro, R. Hosokawa, T. Kimura, T. Kita, M. Komeda, and K. Togashi Thoracoabdominal-aortoiliac MDCT angiography using reduced dose of contrast material. Am. J. Roentgenol., August 1, 2006; 187(2): 548 - 554. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Rieger, A. Mallouhi, T. Tauscher, M. Lutz, and W. R. Jaschke Traumatic Arterial Injuries of the Extremities: Initial Evaluation with MDCT Angiography. Am. J. Roentgenol., March 1, 2006; 186(3): 656 - 664. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Utsunomiya, K. Awai, Y. Tamura, T. Nishiharu, J. Urata, T. Sakamoto, A. Taniguchi, and Y. Yamashita 16-MDCT Aortography with a Low-Dose Contrast Material Protocol Am. J. Roentgenol., February 1, 2006; 186(2): 374 - 378. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. T. Johnson and E. K. Fishman IV Contrast Selection for MDCT: Current Thoughts and Practice Am. J. Roentgenol., February 1, 2006; 186(2): 406 - 415. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Ouwendijk, M. C. J. M. Kock, K. Visser, P. M. T. Pattynama, M. W. de Haan, and M. G. M. Hunink Interobserver Agreement for the Interpretation of Contrast-Enhanced 3D MR Angiography and MDCT Angiography in Peripheral Arterial Disease Am. J. Roentgenol., November 1, 2005; 185(5): 1261 - 1267. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.-F. Ko, C.-C. Huang, S.-H. Ng, T.-Y. Lee, M.-J. Hsieh, F.-Y. Lee, M.-C. Chen, S.-M. Sheen-Chen, and C.-H. Lee MDCT Angiography for Evaluation of the Complete Vascular Tree of Hemodialysis Fistulas Am. J. Roentgenol., November 1, 2005; 185(5): 1268 - 1274. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. C. Chow, A. Napoli, M. B. Klein, J. Chang, and G. D. Rubin Vascular Mapping of the Leg with Multi-Detector Row CT Angiography prior to Free-Flap Transplantation Radiology, October 1, 2005; 237(1): 353 - 360. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Willmann, B. Baumert, T. Schertler, S. Wildermuth, T. Pfammatter, F. R. Verdun, B. Seifert, B. Marincek, and T. Bohm Aortoiliac and Lower Extremity Arteries Assessed with 16-Detector Row CT Angiography: Prospective Comparison with Digital Subtraction Angiography Radiology, September 1, 2005; 236(3): 1083 - 1093. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Josephs Accuracy of Computed Tomographic Angiography and Magnetic Resonance Angiography for Diagnosing Renal Artery Stenosis Perspectives in Vascular Surgery and Endovascular Therapy, June 1, 2005; 17(2): 180-1 - 182. [Abstract] [PDF] |
||||
![]() |
V A Duddalwar Multislice CT angiography: a practical guide to CT angiography in vascular imaging and intervention Br. J. Radiol., December 1, 2004; 77(suppl_1): S27 - S38. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. M. Ho, R. C. Nelson, J. Thomas, E. I. Gimenez, and D. M. DeLong Abdominal Aortic Aneurysms at Multi-Detector Row Helical CT: Optimization with Interactive Determination of Scanning Delay and Contrast Medium Dose Radiology, September 1, 2004; 232(3): 854 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Napoli, C. Catalano, G. Silecchia, P. Fabiano, F. Fraioli, F. Pediconi, F. Venditti, N. Basso, and R. Passariello Laparoscopic Splenectomy: Multi-Detector Row CT for Preoperative Evaluation Radiology, August 1, 2004; 232(2): 361 - 367. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. W. Olin, J. A. Kaufman, D. A. Bluemke, R. O. Bonow, M. D. Gerhard, M. R. Jaff, G. D. Rubin, and W. Hall Atherosclerotic Vascular Disease Conference: Writing Group IV: Imaging Circulation, June 1, 2004; 109(21): 2626 - 2633. [Full Text] [PDF] |
||||
![]() |
S. J. Riederer Coronary Artery MR Angiography: Are We There Yet? Radiology, May 1, 2004; 231(2): 302 - 304. [Full Text] [PDF] |
||||
![]() |
C. Catalano, F. Fraioli, A. Laghi, A. Napoli, M. Bezzi, F. Pediconi, M. Danti, I. Nofroni, and R. Passariello Infrarenal Aortic and Lower-Extremity Arterial Disease: Diagnostic Performance of Multi-Detector Row CT Angiography Radiology, May 1, 2004; 231(2): 555 - 563. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Ota, K. Takase, K. Igarashi, Y. Chiba, K. Haga, H. Saito, and S. Takahashi MDCT Compared with Digital Subtraction Angiography for Assessment of Lower Extremity Arterial Occlusive Disease: Importance of Reviewing Cross-Sectional Images Am. J. Roentgenol., January 1, 2004; 182(1): 201 - 209. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-K. Kim, S.-Y. Park, H.-j. Kim, C.-S. Kim, H.-J. Ahn, T.-Y. Ahn, and K.-S. Cho Living Donor Kidneys: Usefulness of Multi-Detector Row CT for Comprehensive Evaluation Radiology, December 1, 2003; 229(3): 869 - 876. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Willmann, D. Mayer, M. Banyai, L. M. Desbiolles, F. R. Verdun, B. Seifert, B. Marincek, and D. Weishaupt Evaluation of Peripheral Arterial Bypass Grafts with Multi-Detector Row CT Angiography: Comparison with Duplex US and Digital Subtraction Angiography Radiology, November 1, 2003; 229(2): 465 - 474. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Morgan-Hughes, P. E. Owens, A. J. Marshall, and C. A. Roobottom Thoracic Aorta at Multi-Detector Row CT: Motion Artifact with Various Reconstruction Windows Radiology, August 1, 2003; 228(2): 583 - 588. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. E. Chiang, P. M. Boiselle, V. Raptopoulos, K. F. Reynolds, M. P. Rosen, and M. Simon Detection of Pulmonary Embolism: Comparison of Paddlewheel and Coronal CT Reformations--Initial Experience Radiology, August 1, 2003; 228(2): 577 - 582. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tanikake, T. Shimizu, I. Narabayashi, M. Matsuki, K. Masuda, K. Yamamoto, Y. Uesugi, and S. Yoshikawa Three-dimensional CT Angiography of the Hepatic Artery: Use of Multi-Detector Row Helical CT and a Contrast Agent Radiology, June 1, 2003; 227(3): 883 - 889. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kawamoto, R. A. Montgomery, L. P. Lawler, K. M. Horton, and E. K. Fishman Multidetector CT Angiography for Preoperative Evaluation of Living Laparoscopic Kidney Donors Am. J. Roentgenol., June 1, 2003; 180(6): 1633 - 1638. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. L. Martin, K. H. Tay, B. Flak, P. D. Fry, D. L. Doyle, D. C. Taylor, Y. N. Hsiang, and L. S. Machan Multidetector CT Angiography of the Aortoiliac System and Lower Extremities: A Prospective Comparison with Digital Subtraction Angiography Am. J. Roentgenol., April 1, 2003; 180(4): 1085 - 1091. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Ofer, S. S. Nitecki, S. Linn, M. Epelman, D. Fischer, T. Karram, D. Litmanovich, H. Schwartz, A. Hoffman, and A. Engel Multidetector CT Angiography of Peripheral Vascular Disease: A Prospective Comparison with Intraarterial Digital Subtraction Angiography Am. J. Roentgenol., March 1, 2003; 180(3): 719 - 724. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Willmann, S. Wildermuth, T. Pfammatter, J. E. Roos, B. Seifert, P. R. Hilfiker, B. Marincek, and D. Weishaupt Aortoiliac and Renal Arteries: Prospective Intraindividual Comparison of Contrast-enhanced Three-dimensional MR Angiography and Multi-Detector Row CT Angiography Radiology, March 1, 2003; 226(3): 798 - 811. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Mallouhi, M. Rieger, B. Czermak, M. C. Freund, P. Waldenberger, and W. R. Jaschke Volume-Rendered Multidetector CT Angiography: Noninvasive Follow-Up of Patients Treated with Renal Artery Stents Am. J. Roentgenol., January 1, 2003; 180(1): 233 - 239. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Maintz, B. Tombach, K.-U. Juergens, S. Weigel, W. Heindel, and R. Fischbach Revealing In-Stent Stenoses of the Iliac Arteries: Comparison of Multidetector CT with MR Angiography and Digital Radiographic Angiography in a Phantom Model Am. J. Roentgenol., November 1, 2002; 179(5): 1319 - 1322. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Willmann, J. E. Roos, A. Platz, T. Pfammatter, P. R. Hilfiker, B. Marincek, and D. Weishaupt Multidetector CT: Detection of Active Hemorrhage in Patients with Blunt Abdominal Trauma Am. J. Roentgenol., August 1, 2002; 179(2): 437 - 444. [Abstract] [Full Text] [PDF] |
||||
![]() |
U J Schoepf, C R Becker, R D Bruening, B M Ohnesorge, A Huber, L-G Haw, H Hildebrandt, and M F Reiser Multislice CT angiography Imaging, December 15, 2001; 13(5): 357 - 365. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Katz and M. Hon CT Angiography of the Lower Extremities and Aortoiliac System with a Multi-Detector Row Helical CT Scanner: Promise of New Opportunities Fulfilled Radiology, October 1, 2001; 221(1): 7 - 10. [Full Text] [PDF] |
||||
![]() |
G. D. Rubin, A. J. Schmidt, L. J. Logan, and M. C. Sofilos Multi-Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience Radiology, October 1, 2001; 221(1): 146 - 158. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. P. Lawler and E. K. Fishman Multi-Detector Row CT of Thoracic Disease with Emphasis on 3D Volume Rendering and CT Angiography RadioGraphics, September 1, 2001; 21(5): 1257 - 1273. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Rankin, W. Jan, and C. G. Koffman Noninvasive Imaging of Living Related Kidney Donors: Evaluation with CT Angiography and Gadolinium-Enhanced MR Angiography Am. J. Roentgenol., August 1, 2001; 177(2): 349 - 355. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Macari, G. M. Israel, P. Berman, M. Lisi, A. J. Tolia, M. Adelman, and A. J. Megibow Infrarenal Abdominal Aortic Aneurysms at Multi-Detector Row CT Angiography: Intravascular Enhancement without a Timing Acquisition Radiology, August 1, 2001; 220(2): 519 - 523. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Simon, P. M. Boiselle, J. R. Choi, M. P. Rosen, K. Reynolds, and V. Raptopoulos Paddle-Wheel CT Display of Pulmonary Arteries and Other Lung Structures: A New Imaging Approach Am. J. Roentgenol., July 1, 2001; 177(1): 195 - 198. [Full Text] [PDF] |
||||
![]() |
T. R. Jones, R. T. Kaplan, B. Lane, S. W. Atlas, and G. D. Rubin Single- versus Multi-Detector Row CT of the Brain: Quality Assessment Radiology, June 1, 2001; 219(3): 750 - 755. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Hara, C. D. Johnson, R. L. MacCarty, T. J. Welch, C. H. McCollough, and W. S. Harmsen CT Colonography: Single- versus Multi-Detector Row Imaging Radiology, May 1, 2001; 219(2): 461 - 465. [Abstract] [Full Text] |
||||
![]() |
D. Fleischmann, G. D. Rubin, D. S. Paik, S. Y. Yen, P. R. Hilfiker, C. F. Beaulieu, and S. Napel Stair-Step Artifacts with Single versus Multiple Detector-Row Helical CT Radiology, July 1, 2000; 216(1): 185 - 196. [Abstract] [Full Text] |
||||
![]() |
J. E. Roos, J. K. Willmann, D. Weishaupt, M. Lachat, B. Marincek, and P. R. Hilfiker Thoracic Aorta: Motion Artifact Reduction with Retrospective and Prospective Electrocardiography-assisted Multi-Detector Row CT Radiology, January 1, 2002; 222(1): 271 - 277. [Abstract] [Full Text] [PDF] |
||||