Vascular and Interventional Radiology |
1 From the Department of Radiology, Tulane University School of Medicine, 1430 Tulane Ave, New Orleans, LA 70112 (E.K.L.); the Department of Radiology, State University of New York Health Science, Brooklyn (R.G.); the Department of Radiology, Louisiana State University School of Medicine, New Orleans (V.C.S., S.A.); and the Department of Radiology, Duke University Medical Center, Durham, NC (J.R.). Received February 18, 1999; revision requested April 5; final revision received September 28; accepted October 4. Address correspondence to E.K.L.
PURPOSE: To determine whether the use of autologous blood clot seal (ABCS) after biopsy of lung lesions can reduce or prevent pneumothorax.
MATERIALS AND METHODS: The authors evaluated 100 patients (63 men, 37 women; age range, 2778 years) with pleural (n = 23) or deep (n = 77) lesions. Thirty-eight patients had emphysema. Patients were randomly assigned to one of two groups: those in whom the biopsy track was sealed with autologous blood clot (n = 50) and those who did not receive autologous blood clot (n = 50). Biopsy was performed with computed tomographic (CT) guidance and a 19-gauge coaxial system. The autologous blood clot, which ranged from 0.5 to 4.5 mL, was injected while the sheath was being withdrawn.
RESULTS: Pneumothorax developed in four of the 23 patients (17%) with pleural lesions and 19 of the 77 patients (24%) with deep lesions. Pneumothorax occurred in four of the 45 patients (9%) who had deep lesions and received autologous blood clot and in 15 of the 32 patients (47%) who had deep lesions and did not receive autologous blood clot (P < .001). In patients with emphysema, pneumothorax occurred in three of the 20 patients (15%) who received autologous blood clot and 10 of the 14 (71%) who did not (P < .001). There were seven large pneumothoraces necessitating treatment; all occurred in patients who did not receive autologous blood clot.
CONCLUSION: Plugging of biopsy tracks with ABCS, particularly after biopsy of deep lung lesions, significantly reduced the frequency of pneumothoraxparticularly of large pneumothoracesand, therefore, the need for treatment and the attendant cost.
Index terms: Lung, biopsy, 60.126 Lung, CT, 60.12115 Pneumothorax, 60.732
This article has been cited by other articles:
![]() |
H. T. Winer-Muram The solitary pulmonary nodule. Radiology, April 1, 2006; 239(1): 34 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Manhire, M Charig, C Clelland, F Gleeson, R Miller, H Moss, K Pointon, C Richardson, and E Sawicka Guidelines for radiologically guided lung biopsy Thorax, November 1, 2003; 58(11): 920 - 936. [Full Text] [PDF] |
||||
![]() |
L. B. Haramati and G. Aviram What Constitutes Effective Management of Pneumothorax After CT-Guided Needle Biopsy of the Lung? Chest, April 1, 2002; 121(4): 1013 - 1015. [Full Text] [PDF] |
||||
![]() |
J. E. Silberzweig, C. Hilfer, and E. K. Lang Embolization of an Autologous Clot Dr Lang responds: Radiology, May 1, 2001; 219(2): 574 - 574. [Full Text] |
||||