Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lang, E. K.
Right arrow Articles by Ramirez, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lang, E. K.
Right arrow Articles by Ramirez, J.
(Radiology. 2000;216:93-96.)
© RSNA, 2000


Vascular and Interventional Radiology

Autologous Blood Clot Seal to Prevent Pneumothorax at CT-guided Lung Biopsy1

Erich K. Lang, MD, Richard Ghavami, MD, Virginia C. Schreiner, MD, Steven Archibald, MD and Jorje Ramirez, MD

1 From the Department of Radiology, Tulane University School of Medicine, 1430 Tulane Ave, New Orleans, LA 70112 (E.K.L.); the Department of Radiology, State University of New York Health Science, Brooklyn (R.G.); the Department of Radiology, Louisiana State University School of Medicine, New Orleans (V.C.S., S.A.); and the Department of Radiology, Duke University Medical Center, Durham, NC (J.R.). Received February 18, 1999; revision requested April 5; final revision received September 28; accepted October 4. Address correspondence to E.K.L.

PURPOSE: To determine whether the use of autologous blood clot seal (ABCS) after biopsy of lung lesions can reduce or prevent pneumothorax.

MATERIALS AND METHODS: The authors evaluated 100 patients (63 men, 37 women; age range, 27–78 years) with pleural (n = 23) or deep (n = 77) lesions. Thirty-eight patients had emphysema. Patients were randomly assigned to one of two groups: those in whom the biopsy track was sealed with autologous blood clot (n = 50) and those who did not receive autologous blood clot (n = 50). Biopsy was performed with computed tomographic (CT) guidance and a 19-gauge coaxial system. The autologous blood clot, which ranged from 0.5 to 4.5 mL, was injected while the sheath was being withdrawn.

RESULTS: Pneumothorax developed in four of the 23 patients (17%) with pleural lesions and 19 of the 77 patients (24%) with deep lesions. Pneumothorax occurred in four of the 45 patients (9%) who had deep lesions and received autologous blood clot and in 15 of the 32 patients (47%) who had deep lesions and did not receive autologous blood clot (P < .001). In patients with emphysema, pneumothorax occurred in three of the 20 patients (15%) who received autologous blood clot and 10 of the 14 (71%) who did not (P < .001). There were seven large pneumothoraces necessitating treatment; all occurred in patients who did not receive autologous blood clot.

CONCLUSION: Plugging of biopsy tracks with ABCS, particularly after biopsy of deep lung lesions, significantly reduced the frequency of pneumothorax—particularly of large pneumothoraces—and, therefore, the need for treatment and the attendant cost.

Index terms: Lung, biopsy, 60.126 • Lung, CT, 60.12115 • Pneumothorax, 60.732




This article has been cited by other articles:


Home page
RadiologyHome page
H. T. Winer-Muram
The solitary pulmonary nodule.
Radiology, April 1, 2006; 239(1): 34 - 49.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
A Manhire, M Charig, C Clelland, F Gleeson, R Miller, H Moss, K Pointon, C Richardson, and E Sawicka
Guidelines for radiologically guided lung biopsy
Thorax, November 1, 2003; 58(11): 920 - 936.
[Full Text] [PDF]


Home page
ChestHome page
L. B. Haramati and G. Aviram
What Constitutes Effective Management of Pneumothorax After CT-Guided Needle Biopsy of the Lung?
Chest, April 1, 2002; 121(4): 1013 - 1015.
[Full Text] [PDF]


Home page
RadiologyHome page
J. E. Silberzweig, C. Hilfer, and E. K. Lang
Embolization of an Autologous Clot Dr Lang responds:
Radiology, May 1, 2001; 219(2): 574 - 574.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2000 by the Radiological Society of North America.