Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davis, S. D.
Right arrow Articles by Hentel, K. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davis, S. D.
Right arrow Articles by Hentel, K. D.
(Radiology. 2000;216:97-106.)
© RSNA, 2000


Thoracic Imaging

Obliquely Oriented Superior Accessory Fissure of the Lower Lobe of the Lung: CT Evaluation of the Normal Appearance and Effect on the Distribution of Parenchymal and Pleural Opacities1

Sheila D. Davis, MD, Lawrence S. Yu, MD and Keith D. Hentel, MD

1 From the Department of Radiology, New York Presbyterian Hospital, 525 E 68th St, New York, NY 10021. Received November 19, 1998; revision requested January 25, 1999; final revision received December 21; accepted January 12, 2000. Address correspondence to S.D.D.

PURPOSE: To review computed tomographic (CT) and radiographic features of an oblique superior accessory fissure in the lower lobe of the lung.

MATERIALS AND METHODS: CT scans in 34 patients with a prospectively identified accessory fissure of the lower lobe were reviewed and correlated with chest radiographs (31 patients). The fissure and its relationship to segmental bronchovascular structures were evaluated on transverse scans. Three-dimensional (3D) shaded surface display (SSD) reconstructions were obtained from spiral volume data (six patients).

RESULTS: Thirty-four patients had 36 accessory fissures (26 right, 10 left). Four of the 36 accessory fissures were manifested by a normal fissure line; two, by slight thickening or minimal linear atelectasis; 16, by thicker linear or subsegmental atelectasis; two, by contiguous tumor infiltration; one, by adjacent consolidation; and 11, by intrafissural extension of pleural fluid. Analysis of bronchovascular structures revealed that this fissure was the superior accessory fissure. The 3D SSD reconstructions demonstrated an oblique orientation. On frontal radiographs, presence of this fissure correlated with a curvilinear band of atelectasis coursing inferomedially and obliquely from its intersection with the lateral aspect of the major fissure toward the infrahilar region on the right and the heart border on the left. Chest radiographs also showed intrafissural extension of pleural fluid.

CONCLUSION: A superior accessory fissure of the lower lobe, more common on the right than on the left, can be identified at transverse CT. Contrary to previous descriptions, it may be oblique, as findings on transverse images suggest and 3D SSD reconstructions confirm. Its presence correlates with characteristic patterns of atelectasis and pleural fluid collection on conventional radiographs.

Index terms: Lung, anatomy, 60.92, 63.139, 65.139 • Lung, CT, 60.12115 • Lung, radiography, 60.11 • Pleura, 66.139 • Pleura, CT, 66.12115