Genitourinary Imaging |
1 From the Departments of Radiology (E.J.H., D.G.M., R.J.W., E.K.O.) and Surgery (M.J.M., G.A.W.), Thomas Jefferson University Hospital, 132 S 10th St, Philadelphia, PA 19107-5244. From the 1999 RSNA scientific assembly. Received August 24, 1999; revision requested October 5; revision received October 25; accepted November 2. Address correspondence to E.J.H. (e-mail: Ethan.Halpern@mail.tju.edu).
PURPOSE: To compare computed tomographic (CT) angiography and magnetic resonance (MR) angiography for preoperative evaluation of living renal donors.
MATERIALS AND METHODS: Thirty-five living renal donors underwent preoperative contrast materialenhanced CT angiography and gadolinium-enhanced MR angiography. Each study was interpreted by two independent radiologists blinded to all other studies and to interpretations provided by other reviewers. Eighteen kidneys had surgical correlation.
RESULTS: CT demonstrated 33 supernumerary arteries in 19 patients, bilateral solitary arteries in 16 patients, and 18 proximal arterial branches in 16 patients. MR demonstrated 26 supernumerary arteries in 15 patients, bilateral solitary renal arteries in 20 patients, and 21 proximal arterial branches in 16 patients. Interobserver agreements for MR (
= 0.74) and CT (
= 0.73) were similar to the agreement between MR and CT (
= 0.74). Among the kidneys chosen for nephrectomy, one small accessory artery and one proximal arterial branch were missed with CT and MR. Two of the accessory arteries suggested at CT were not found at nephrectomy. By averaging data for both modalities, supernumerary arteries were present in 49% of kidney donors and were bilateral in approximately 17%. Proximal arterial branches were present in 46% of kidney donors.
CONCLUSION: Preoperative CT and MR angiography of the renal arteries in renal donors demonstrate substantial agreement. Interobserver disagreement in the interpretation of CT and MR angiograms is related to 12-mm-diameter vessels.
Index terms: Computed tomography (CT), angiography, 81.12116 Kidney, blood supply, 961.13 Kidney, transplantation, 81.4551 Magnetic resonance (MR), vascular studies, 81.12142 Renal arteries, CT, 961.12916 Renal arteries, MR, 961.12942
This article has been cited by other articles:
![]() |
A. Holden, A. Smith, P. Dukes, H. Pilmore, and M. Yasutomi Assessment of 100 Live Potential Renal Donors for Laparoscopic Nephrectomy with Multi-Detector Row Helical CT Radiology, December 1, 2005; 237(3): 973 - 980. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. C. J. M. Kock, J. N. M. Ijzermans, K. Visser, S. M. Hussain, W. Weimar, P. M. T. Pattynama, G. P. Krestin, and M. G. M. Hunink Contrast-Enhanced MR Angiography and Digital Subtraction Angiography in Living Renal Donors: Diagnostic Agreement, Impact on Decision Making, and Costs Am. J. Roentgenol., August 1, 2005; 185(2): 448 - 456. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Kim, J. H. Kim, S.-J. Bae, and K.-S. Cho CT Angiography for Evaluation of Living Renal Donors: Comparison of Four Reconstruction Methods Am. J. Roentgenol., August 1, 2004; 183(2): 471 - 477. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Matsuki, H. Kani, F. Tatsugami, S. Yoshikawa, I. Narabayashi, S.-W. Lee, H. Shinohara, E. Nomura, and N. Tanigawa Preoperative Assessment of Vascular Anatomy Around the Stomach by 3D Imaging Using MDCT Before Laparoscopy-Assisted Gastrectomy Am. J. Roentgenol., July 1, 2004; 183(1): 145 - 151. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-K. Kim, S.-Y. Park, H.-j. Kim, C.-S. Kim, H.-J. Ahn, T.-Y. Ahn, and K.-S. Cho Living Donor Kidneys: Usefulness of Multi-Detector Row CT for Comprehensive Evaluation Radiology, December 1, 2003; 229(3): 869 - 876. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kawamoto, R. A. Montgomery, L. P. Lawler, K. M. Horton, and E. K. Fishman Multidetector CT Angiography for Preoperative Evaluation of Living Laparoscopic Kidney Donors Am. J. Roentgenol., June 1, 2003; 180(6): 1633 - 1638. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. Hussain, M. C. J. M. Kock, J. N. M. IJzermans, P. M. T. Pattynama, M. G. Myriam Hunink, and G. P. Krestin MR Imaging: A "One-Stop Shop" Modality for Preoperative Evaluation of Potential Living Kidney Donors RadioGraphics, March 1, 2003; 23(2): 505 - 520. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Willmann, S. Wildermuth, T. Pfammatter, J. E. Roos, B. Seifert, P. R. Hilfiker, B. Marincek, and D. Weishaupt Aortoiliac and Renal Arteries: Prospective Intraindividual Comparison of Contrast-enhanced Three-dimensional MR Angiography and Multi-Detector Row CT Angiography Radiology, March 1, 2003; 226(3): 798 - 811. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. S. Liem, M. C. J. M. Kock, J. N. M. Ijzermans, W. Weimar, K. Visser, and M.G. M. Hunink Living Renal Donors: Optimizing the Imaging Strategy--Decision- and Cost-effectiveness Analysis Radiology, January 1, 2003; 226(1): 53 - 62. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M. Israel, V. S. Lee, M. Edye, G. A. Krinsky, M. T. Lavelle, T. Diflo, and J. C. Weinreb Comprehensive MR Imaging in the Preoperative Evaluation of Living Donor Candidates for Laparoscopic Nephrectomy: Initial Experience Radiology, November 1, 2002; 225(2): 427 - 432. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Jha, S. J. Korangy, S. M. Ascher, J. Takahama, P. C. Kuo, and L. B. Johnson MR Angiography and Preoperative Evaluation for Laparoscopic Donor Nephrectomy Am. J. Roentgenol., June 1, 2002; 178(6): 1489 - 1495. [Abstract] [Full Text] [PDF] |
||||
![]() |
U J Schoepf, C R Becker, R D Bruening, B M Ohnesorge, A Huber, L-G Haw, H Hildebrandt, and M F Reiser Multislice CT angiography Imaging, December 15, 2001; 13(5): 357 - 365. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Glockner Three-dimensional Gadolinium-enhanced MR Angiography: Applications for Abdominal Imaging RadioGraphics, March 1, 2001; 21(2): 357 - 370. [Abstract] [Full Text] [PDF] |
||||