Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yamashita, Y.
Right arrow Articles by Narabayashi, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamashita, Y.
Right arrow Articles by Narabayashi, I.
(Radiology. 2000;216:718-723.)
© RSNA, 2000


Gastrointestinal Imaging

Abdominal Helical CT: Evaluation of Optimal Doses of Intravenous Contrast Material-A Prospective Randomized Study1

Yasuyuki Yamashita, MD, Yasuyuki Komohara, MD, Mutsumasa Takahashi, MD, Masafumi Uchida, MD, Naofumi Hayabuchi, MD, Tadafumi Shimizu, MD and Isamu Narabayashi, MD

1 From the Department of Radiology, Kumamoto University School of Medicine, 1-1-1 Honjo, Kumamoto, 860-0811, Japan (Y.Y., Y.K., M.T.); the Department of Radiology, Kurume University School of Medicine, Japan (M.U., N.H.); and the Department of Radiology, Osaka Medical College, Japan (T.S., I.N.). Received July 27, 1999; revision requested August 30; revision received December 16; accepted December 21. Address correspondence to Y.Y. (e-mail: yama@kaiju.medic.kumamoto-u.ac.jp).

PURPOSE: To determine the optimal dose of intravenous contrast material for helical computed tomography (CT) of the abdomen on the basis of patient weight.

MATERIALS AND METHODS: A prospective randomized study of helical CT of the abdomen was performed by using different doses of intravenous contrast material in 221 patients (mean body weight, 57.3 kg) who were assigned randomly to three groups receiving 1.5, 2.0, or 2.5 mL/kg or a fixed dose of 100 mL of iopamidol 300. The degree of enhancement was scored visually. The CT numbers (HU) of the aorta, portal vein, liver, and pancreas were obtained at three levels of the abdomen.

RESULTS: In arterial enhancement, the 2.0 mL/kg, 2.5 mL/kg, and fixed-dose groups were significantly better than the 1.5 mL/kg group, but there was no significant difference among the 2.0 mL/kg, 2.5 mL/kg, or fixed-dose groups. The degree of enhancement of the liver, pancreas, and portal vein increased with larger doses. At visual analysis, hepatic parenchymal enhancement was graded as good or excellent in 64% of the 1.5 mL/kg, 85% of the 2.0 mL/kg, 94% of the 2.5 mL/kg, and 65% of the fixed-dose groups.

CONCLUSION: When dose was tailored to patient weight, the use of 2.0–2.5 mL/kg of intravenous contrast material produced better results than did 1.5 mL/kg or a fixed dose. Arterial enhancement did not differ among the 2.0 mL/kg, 2.5 mL/kg, or fixed-dose groups.

Index terms: Abdomen, CT, 70.12112, 70.12115 • Aorta, CT, 981.12912, 981.12915 • Computed tomography (CT), comparative studies, 70.12112, 70.12115 • Computed tomography (CT), contrast media, 70.12112, 70.12115 • Liver, CT, 761.12112, 761.12115 • Pancreas, CT, 770.12112, 770.12115 • Portal vein, CT, 957.12912, 957.12915




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
X. Fei, X. Du, Q. Yang, Y. Shen, P. Li, J. Liao, and K. Li
64-MDCT Coronary Angiography: Phantom Study of Effects of Vascular Attenuation on Detection of Coronary Stenosis
Am. J. Roentgenol., July 1, 2008; 191(1): 43 - 49.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. F. Behrendt, A. H. Mahnken, S. Stanzel, P. Seidensticker, E. Jost, R. W. Gunther, and G. Muhlenbruch
Intraindividual Comparison of Contrast Media Concentrations for Combined Abdominal and Thoracic MDCT
Am. J. Roentgenol., July 1, 2008; 191(1): 145 - 150.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Okada, T. Murakami, S. Kumano, I. Imaoka, T. Shimono, R. Ashikaga, and M. Hosono
Comparison Between One-Route and Two-Route Injection for Liver and Aortic Enhancement Using MDCT
Am. J. Roentgenol., June 1, 2008; 190(6): W323 - W326.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. Yanaga, K. Awai, T. Nakaura, T. Namimoto, S. Oda, Y. Funama, and Y. Yamashita
Optimal Contrast Dose for Depiction of Hypervascular Hepatocellular Carcinoma at Dynamic CT Using 64-MDCT
Am. J. Roentgenol., April 1, 2008; 190(4): 1003 - 1009.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard
Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity
Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. J. Kim, T. H. Kim, S. J. Kim, D. P. Kim, C. S. Oh, Y. H. Ryu, Y. J. Kim, and B. W. Choi
Saline Flush Effect for Enhancement of Aorta and Coronary Arteries at Multidetector CT Coronary Angiography
Radiology, January 1, 2008; 246(1): 110 - 115.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Yanaga, K. Awai, Y. Nakayama, T. Nakaura, Y. Tamura, M. Hatemura, and Y. Yamashita
Pancreas: Patient Body Weight tailored Contrast Material Injection Protocol versus Fixed Dose Protocol at Dynamic CT
Radiology, November 1, 2007; 245(2): 475 - 482.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
F. Tatsugami, M. Matsuki, G. Nakai, M. Tanikake, S. Yoshikawa, I. Narabayashi, K. Miyaji, A. Asai, S. Fujiwara, Y. Hongo, et al.
Hepatic Computed Tomography for Simultaneous Depiction of Hepatocellular Carcinoma, Intrahepatic Portal Veins, and Hepatic Veins in Real-time Virtual Sonography: Initial Experience
J. Ultrasound Med., August 1, 2007; 26(8): 1065 - 1069.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. Andreini, G. Pontone, M. Pepi, G. Ballerini, A. L. Bartorelli, A. Magini, C. Quaglia, E. Nobili, and P. Agostoni
Diagnostic Accuracy of Multidetector Computed Tomography Coronary Angiography in Patients With Dilated Cardiomyopathy
J. Am. Coll. Cardiol., May 22, 2007; 49(20): 2044 - 2050.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. M. Ho, R. C. Nelson, and D. M. DeLong
Determining Contrast Medium Dose and Rate on Basis of Lean Body Weight: Does This Strategy Improve Patient-to-Patient Uniformity of Hepatic Enhancement during Multi-Detector Row CT?
Radiology, May 1, 2007; 243(2): 431 - 437.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Kuehl, P. Veit, S. J. Rosenbaum, A. Bockisch, and G. Antoch
Can PET/CT Replace Separate Diagnostic CT for Cancer Imaging? Optimizing CT Protocols for Imaging Cancers of the Chest and Abdomen
J. Nucl. Med., January 1, 2007; 48(1_suppl): 45S - 57S.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Goshima, M. Kanematsu, H. Kondo, R. Yokoyama, T. Miyoshi, H. Kato, Y. Tsuge, Y. Shiratori, H. Hoshi, M. Onozuka, et al.
Pancreas: Optimal Scan Delay for Contrast-enhanced Multi-Detector Row CT
Radiology, October 1, 2006; 241(1): 167 - 174.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Itoh, M. Ikeda, H. Satake, T. Ota, and T. Ishigaki
The effect of patient age on contrast enhancement during CT of the pancreatobiliary region.
Am. J. Roentgenol., August 1, 2006; 187(2): 505 - 510.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. Orlandini, S. Boini, S. Iochum-Duchamps, T. Batch, X. Zhu, and A. Blum
Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT.
Am. J. Roentgenol., August 1, 2006; 187(2): 511 - 515.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Kubo, E. Tadamura, M. Yamamuro, R. Hosokawa, T. Kimura, T. Kita, M. Komeda, and K. Togashi
Thoracoabdominal-aortoiliac MDCT angiography using reduced dose of contrast material.
Am. J. Roentgenol., August 1, 2006; 187(2): 548 - 554.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Goshima, M. Kanematsu, H. Kondo, R. Yokoyama, T. Miyoshi, H. Nishibori, H. Kato, H. Hoshi, M. Onozuka, and N. Moriyama
MDCT of the liver and hypervascular hepatocellular carcinomas: optimizing scan delays for bolus-tracking techniques of hepatic arterial and portal venous phases.
Am. J. Roentgenol., July 1, 2006; 187(1): W25 - W32.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Beyer, G. Antoch, A. Bockisch, and J. Stattaus
Optimized Intravenous Contrast Administration for Diagnostic Whole-Body 18F-FDG PET/CT
J. Nucl. Med., March 1, 2005; 46(3): 429 - 435.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Awai, M. Inoue, Y. Yagyu, M. Watanabe, T. Sano, S. Nin, R. Koike, Y. Nishimura, and Y. Yamashita
Moderate versus High Concentration of Contrast Material for Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast at Multi-Detector Row CT
Radiology, December 1, 2004; 233(3): 682 - 688.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S Fenchel, T R Fleiter, A J Aschoff, R van Gessel, H-J Brambs, and E M Merkle
Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas
Br. J. Radiol., October 1, 2004; 77(922): 821 - 830.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Ito, T. Fujita, A. Shimizu, S. Koike, K. Sasaki, N. Matsunaga, S. Hibino, and M. Yuhara
Multiarterial Phase Dynamic MRI of Small Early Enhancing Hepatic Lesions in Cirrhosis or Chronic Hepatitis: Differentiating Between Hypervascular Hepatocellular Carcinomas and Pseudolesions
Am. J. Roentgenol., September 1, 2004; 183(3): 699 - 705.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Furuta, K. Ito, T. Fujita, S. Koike, A. Shimizu, and N. Matsunaga
Hepatic Enhancement in Multiphasic Contrast-Enhanced MDCT: Comparison of High- and Low-Iodine-Concentration Contrast Medium in Same Patients with Chronic Liver Disease
Am. J. Roentgenol., July 1, 2004; 183(1): 157 - 162.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Awai, K. Hiraishi, and S. Hori
Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient Weight
Radiology, January 1, 2004; 230(1): 142 - 150.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Nakamoto, B. B. Chin, D. L. Kraitchman, L. P. Lawler, L. T. Marshall, and R. L. Wahl
Effects of Nonionic Intravenous Contrast Agents at PET/CT Imaging: Phantom and Canine Studies
Radiology, June 1, 2003; 227(3): 817 - 824.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. A. Haider, M. M. Amitai, D. C. Rappaport, M. E. O'Malley, A. E. Hanbidge, M. Redston, G. A. Lockwood, and S. Gallinger
Multi-Detector Row Helical CT in Preoperative Assessment of Small (<=1.5 cm) Liver Metastases: Is Thinner Collimation Better?
Radiology, October 1, 2002; 225(1): 137 - 142.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Hirai, Y. Korogi, K. Ono, Y. Murata, K. Suginohara, T. Omori, S. Uemura, and M. Takahashi
Preoperative Evaluation of Intracranial Aneurysms: Usefulness of Intraarterial 3D CT Angiography and Conventional Angiography with a Combined Unit—Initial Experience
Radiology, August 1, 2001; 220(2): 499 - 505.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2000 by the Radiological Society of North America.