Gastrointestinal Imaging |
1 From the Department of Radiology, Kumamoto University School of Medicine, 1-1-1 Honjo, Kumamoto, 860-0811, Japan (Y.Y., Y.K., M.T.); the Department of Radiology, Kurume University School of Medicine, Japan (M.U., N.H.); and the Department of Radiology, Osaka Medical College, Japan (T.S., I.N.). Received July 27, 1999; revision requested August 30; revision received December 16; accepted December 21. Address correspondence to Y.Y. (e-mail: yama@kaiju.medic.kumamoto-u.ac.jp).
PURPOSE: To determine the optimal dose of intravenous contrast material for helical computed tomography (CT) of the abdomen on the basis of patient weight.
MATERIALS AND METHODS: A prospective randomized study of helical CT of the abdomen was performed by using different doses of intravenous contrast material in 221 patients (mean body weight, 57.3 kg) who were assigned randomly to three groups receiving 1.5, 2.0, or 2.5 mL/kg or a fixed dose of 100 mL of iopamidol 300. The degree of enhancement was scored visually. The CT numbers (HU) of the aorta, portal vein, liver, and pancreas were obtained at three levels of the abdomen.
RESULTS: In arterial enhancement, the 2.0 mL/kg, 2.5 mL/kg, and fixed-dose groups were significantly better than the 1.5 mL/kg group, but there was no significant difference among the 2.0 mL/kg, 2.5 mL/kg, or fixed-dose groups. The degree of enhancement of the liver, pancreas, and portal vein increased with larger doses. At visual analysis, hepatic parenchymal enhancement was graded as good or excellent in 64% of the 1.5 mL/kg, 85% of the 2.0 mL/kg, 94% of the 2.5 mL/kg, and 65% of the fixed-dose groups.
CONCLUSION: When dose was tailored to patient weight, the use of 2.02.5 mL/kg of intravenous contrast material produced better results than did 1.5 mL/kg or a fixed dose. Arterial enhancement did not differ among the 2.0 mL/kg, 2.5 mL/kg, or fixed-dose groups.
Index terms: Abdomen, CT, 70.12112, 70.12115 Aorta, CT, 981.12912, 981.12915 Computed tomography (CT), comparative studies, 70.12112, 70.12115 Computed tomography (CT), contrast media, 70.12112, 70.12115 Liver, CT, 761.12112, 761.12115 Pancreas, CT, 770.12112, 770.12115 Portal vein, CT, 957.12912, 957.12915
This article has been cited by other articles:
![]() |
X. Fei, X. Du, Q. Yang, Y. Shen, P. Li, J. Liao, and K. Li 64-MDCT Coronary Angiography: Phantom Study of Effects of Vascular Attenuation on Detection of Coronary Stenosis Am. J. Roentgenol., July 1, 2008; 191(1): 43 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. F. Behrendt, A. H. Mahnken, S. Stanzel, P. Seidensticker, E. Jost, R. W. Gunther, and G. Muhlenbruch Intraindividual Comparison of Contrast Media Concentrations for Combined Abdominal and Thoracic MDCT Am. J. Roentgenol., July 1, 2008; 191(1): 145 - 150. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Okada, T. Murakami, S. Kumano, I. Imaoka, T. Shimono, R. Ashikaga, and M. Hosono Comparison Between One-Route and Two-Route Injection for Liver and Aortic Enhancement Using MDCT Am. J. Roentgenol., June 1, 2008; 190(6): W323 - W326. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Yanaga, K. Awai, T. Nakaura, T. Namimoto, S. Oda, Y. Funama, and Y. Yamashita Optimal Contrast Dose for Depiction of Hypervascular Hepatocellular Carcinoma at Dynamic CT Using 64-MDCT Am. J. Roentgenol., April 1, 2008; 190(4): 1003 - 1009. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Kim, T. H. Kim, S. J. Kim, D. P. Kim, C. S. Oh, Y. H. Ryu, Y. J. Kim, and B. W. Choi Saline Flush Effect for Enhancement of Aorta and Coronary Arteries at Multidetector CT Coronary Angiography Radiology, January 1, 2008; 246(1): 110 - 115. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Yanaga, K. Awai, Y. Nakayama, T. Nakaura, Y. Tamura, M. Hatemura, and Y. Yamashita Pancreas: Patient Body Weight tailored Contrast Material Injection Protocol versus Fixed Dose Protocol at Dynamic CT Radiology, November 1, 2007; 245(2): 475 - 482. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Tatsugami, M. Matsuki, G. Nakai, M. Tanikake, S. Yoshikawa, I. Narabayashi, K. Miyaji, A. Asai, S. Fujiwara, Y. Hongo, et al. Hepatic Computed Tomography for Simultaneous Depiction of Hepatocellular Carcinoma, Intrahepatic Portal Veins, and Hepatic Veins in Real-time Virtual Sonography: Initial Experience J. Ultrasound Med., August 1, 2007; 26(8): 1065 - 1069. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Andreini, G. Pontone, M. Pepi, G. Ballerini, A. L. Bartorelli, A. Magini, C. Quaglia, E. Nobili, and P. Agostoni Diagnostic Accuracy of Multidetector Computed Tomography Coronary Angiography in Patients With Dilated Cardiomyopathy J. Am. Coll. Cardiol., May 22, 2007; 49(20): 2044 - 2050. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. M. Ho, R. C. Nelson, and D. M. DeLong Determining Contrast Medium Dose and Rate on Basis of Lean Body Weight: Does This Strategy Improve Patient-to-Patient Uniformity of Hepatic Enhancement during Multi-Detector Row CT? Radiology, May 1, 2007; 243(2): 431 - 437. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kuehl, P. Veit, S. J. Rosenbaum, A. Bockisch, and G. Antoch Can PET/CT Replace Separate Diagnostic CT for Cancer Imaging? Optimizing CT Protocols for Imaging Cancers of the Chest and Abdomen J. Nucl. Med., January 1, 2007; 48(1_suppl): 45S - 57S. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Goshima, M. Kanematsu, H. Kondo, R. Yokoyama, T. Miyoshi, H. Kato, Y. Tsuge, Y. Shiratori, H. Hoshi, M. Onozuka, et al. Pancreas: Optimal Scan Delay for Contrast-enhanced Multi-Detector Row CT Radiology, October 1, 2006; 241(1): 167 - 174. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Itoh, M. Ikeda, H. Satake, T. Ota, and T. Ishigaki The effect of patient age on contrast enhancement during CT of the pancreatobiliary region. Am. J. Roentgenol., August 1, 2006; 187(2): 505 - 510. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Orlandini, S. Boini, S. Iochum-Duchamps, T. Batch, X. Zhu, and A. Blum Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT. Am. J. Roentgenol., August 1, 2006; 187(2): 511 - 515. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kubo, E. Tadamura, M. Yamamuro, R. Hosokawa, T. Kimura, T. Kita, M. Komeda, and K. Togashi Thoracoabdominal-aortoiliac MDCT angiography using reduced dose of contrast material. Am. J. Roentgenol., August 1, 2006; 187(2): 548 - 554. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Goshima, M. Kanematsu, H. Kondo, R. Yokoyama, T. Miyoshi, H. Nishibori, H. Kato, H. Hoshi, M. Onozuka, and N. Moriyama MDCT of the liver and hypervascular hepatocellular carcinomas: optimizing scan delays for bolus-tracking techniques of hepatic arterial and portal venous phases. Am. J. Roentgenol., July 1, 2006; 187(1): W25 - W32. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Beyer, G. Antoch, A. Bockisch, and J. Stattaus Optimized Intravenous Contrast Administration for Diagnostic Whole-Body 18F-FDG PET/CT J. Nucl. Med., March 1, 2005; 46(3): 429 - 435. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, M. Inoue, Y. Yagyu, M. Watanabe, T. Sano, S. Nin, R. Koike, Y. Nishimura, and Y. Yamashita Moderate versus High Concentration of Contrast Material for Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast at Multi-Detector Row CT Radiology, December 1, 2004; 233(3): 682 - 688. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Fenchel, T R Fleiter, A J Aschoff, R van Gessel, H-J Brambs, and E M Merkle Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas Br. J. Radiol., October 1, 2004; 77(922): 821 - 830. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Ito, T. Fujita, A. Shimizu, S. Koike, K. Sasaki, N. Matsunaga, S. Hibino, and M. Yuhara Multiarterial Phase Dynamic MRI of Small Early Enhancing Hepatic Lesions in Cirrhosis or Chronic Hepatitis: Differentiating Between Hypervascular Hepatocellular Carcinomas and Pseudolesions Am. J. Roentgenol., September 1, 2004; 183(3): 699 - 705. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Furuta, K. Ito, T. Fujita, S. Koike, A. Shimizu, and N. Matsunaga Hepatic Enhancement in Multiphasic Contrast-Enhanced MDCT: Comparison of High- and Low-Iodine-Concentration Contrast Medium in Same Patients with Chronic Liver Disease Am. J. Roentgenol., July 1, 2004; 183(1): 157 - 162. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, K. Hiraishi, and S. Hori Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient Weight Radiology, January 1, 2004; 230(1): 142 - 150. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Nakamoto, B. B. Chin, D. L. Kraitchman, L. P. Lawler, L. T. Marshall, and R. L. Wahl Effects of Nonionic Intravenous Contrast Agents at PET/CT Imaging: Phantom and Canine Studies Radiology, June 1, 2003; 227(3): 817 - 824. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Haider, M. M. Amitai, D. C. Rappaport, M. E. O'Malley, A. E. Hanbidge, M. Redston, G. A. Lockwood, and S. Gallinger Multi-Detector Row Helical CT in Preoperative Assessment of Small (<=1.5 cm) Liver Metastases: Is Thinner Collimation Better? Radiology, October 1, 2002; 225(1): 137 - 142. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Hirai, Y. Korogi, K. Ono, Y. Murata, K. Suginohara, T. Omori, S. Uemura, and M. Takahashi Preoperative Evaluation of Intracranial Aneurysms: Usefulness of Intraarterial 3D CT Angiography and Conventional Angiography with a Combined Unit—Initial Experience Radiology, August 1, 2001; 220(2): 499 - 505. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |