Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hug, J.
Right arrow Articles by Fleck, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hug, J.
Right arrow Articles by Fleck, E.
(Radiology. 2000;216:781-787.)
© RSNA, 2000


Cardiac Imaging

Coronary Arterial Stents: Safety and Artifacts during MR Imaging1

Jürgen Hug, MD, Eike Nagel, MD, Axel Bornstedt, PhD, Bernhard Schnackenburg, PhD, Helmut Oswald, PhD and Eckart Fleck, MD

1 From the Department of Internal Medicine and Cardiology, Charité, Campus Virchow-Klinikum Humboldt University & German Heart Institute, Augustenburger Platz 1, 13353 Berlin, Germany (J.H., E.N., A.B., H.O., E.F.), and Philips Medical Systems, Hamburg, Germany (B.S.). Received December 28, 1998; revision requested February 23, 1999; final revision received November 16; accepted December 6. Address correspondence to J.H. (e-mail: Juergen.hug@charite.de).

PURPOSE: To investigate the safety and imaging artifacts with different coronary arterial stents and magnetic resonance (MR) imaging sequences.

MATERIALS AND METHODS: The heating, artifacts, and ferromagnetism with different stents were studied with a 1.5-T MR tomograph with ultrafast gradients by using turbo spin-echo, turbo gradient-echo, and echo-planar imaging sequences. Nineteen stents, which were 8–25 mm in length and 3.0–4.5 mm in diameter, were evaluated. Stent deviation induced by the magnetic field and during MR imaging, migration, and heating caused by the radio-frequency pulses were examined. The size of imaging artifacts was measured with all the stents under standardized conditions and with six stents after their implantation into the coronary arteries of freshly explanted pig hearts.

RESULTS: All except two types of stents showed minimal ferromagnetism. No device migration or heating was induced. Turbo spin-echo images had minimal artifacts; larger artifacts were seen on the turbo gradient-echo and echo-planar images. With ultrafast gradients, the artifacts on the echo-planar images were substantially reduced.

CONCLUSION: The studied coronary stents were not influenced by heating or motion during 1.5-T MR imaging. Artifact size differed according to the type and size of the stent and the MR imaging sequence used. Thus, patients with these stents can be safely examined.

Index terms: Coronary vessels, MR, 54.121411, 54.121412, 54.121416, • Coronary vessels, stents and prostheses, 54.126 • Magnetic resonance (MR), artifact, 54.121411, 54.121412, 54.121416 • Magnetic resonance (MR), rapid imaging, 54.121411, 54.121412, 54.121416, • Magnetic resonance (MR), safety, 54.121411, 54.121412, 54.121416




This article has been cited by other articles:


Home page
CirculationHome page
G. N. Levine, A. S. Gomes, A. E. Arai, D. A. Bluemke, S. D. Flamm, E. Kanal, W. J. Manning, E. T. Martin, J. M. Smith, N. Wilke, et al.
Safety of Magnetic Resonance Imaging in Patients With Cardiovascular Devices: An American Heart Association Scientific Statement From the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: Endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance
Circulation, December 11, 2007; 116(24): 2878 - 2891.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Muhlenbruch, A. H. Mahnken, M. Das, R. Blindt, C. Hohl, J. E. Wildberger, R. W. Gunther, H. P. Kuhl, and R. Koos
Evaluation of Aortocoronary Bypass Stents with Cardiac MDCT Compared with Conventional Catheter Angiography
Am. J. Roentgenol., February 1, 2007; 188(2): 361 - 369.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. C. Genson, C. E. Blane, M. A. Helvie, S. A. Waits, and T. L. Chenevert
Effects on Breast MRI of Artifacts Caused by Metallic Tissue Marker Clips
Am. J. Roentgenol., February 1, 2007; 188(2): 372 - 376.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. R. Patel, T. S. E. Albert, D. E. Kandzari, E. F. Honeycutt, L. K. Shaw, M. H. Sketch Jr, M. D. Elliott, R. M. Judd, and R. J. Kim
Acute Myocardial Infarction: Safety of Cardiac MR Imaging after Percutaneous Revascularization with Stents
Radiology, September 1, 2006; 240(3): 674 - 680.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
F. Pugliese, F. Cademartiri, C. van Mieghem, W. B. Meijboom, P. Malagutti, N. R. A. Mollet, C. Martinoli, P. J. de Feyter, and G. P. Krestin
Multidetector CT for visualization of coronary stents.
RadioGraphics, May 1, 2006; 26(3): 887 - 904.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Spuentrup, A. Ruebben, A. Mahnken, M. Stuber, C. Kolker, T. H. Nguyen, R. W. Gunther, and A. Buecker
Artifact-Free Coronary Magnetic Resonance Angiography and Coronary Vessel Wall Imaging in the Presence of a New, Metallic, Coronary Magnetic Resonance Imaging Stent
Circulation, March 1, 2005; 111(8): 1019 - 1026.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
F. G. Shellock, M. Gounis, and A. Wakhloo
Detachable Coil for Cerebral Aneurysms: In Vitro Evaluation of Magnetic Field Interactions, Heating, and Artifacts at 3T
AJNR Am. J. Neuroradiol., February 1, 2005; 26(2): 363 - 366.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S K Prasad and D J Pennell
Safety of cardiovascular magnetic resonance in patients with cardiovascular implants and devices
Heart, November 1, 2004; 90(11): 1241 - 1244.
[Full Text] [PDF]


Home page
RadiologyHome page
F. G. Shellock and J. V. Crues
MR Procedures: Biologic Effects, Safety, and Patient Care
Radiology, September 1, 2004; 232(3): 635 - 652.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. C. Gerber, P. Fasseas, R. J. Lennon, V. U. Valeti, C. P. Wood, J. F. Breen, and P. B. Berger
Clinical safety of magnetic resonanceimaging early after coronary artery stent placement
J. Am. Coll. Cardiol., October 1, 2003; 42(7): 1295 - 1298.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Spuentrup, A. Ruebben, M. Stuber, R. W. Gunther, and A. Buecker
Metallic Renal Artery MR Imaging Stent: Artifact-free Lumen Visualization with Projection and Standard Renal MR Angiography
Radiology, June 1, 2003; 227(3): 897 - 902.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Nagel, T. Thouet, C. Klein, S. Schalla, A. Bornstedt, B. Schnackenburg, J. Hug, E. Wellnhofer, and E. Fleck
Noninvasive Determination of Coronary Blood Flow Velocity With Cardiovascular Magnetic Resonance in Patients After Stent Deployment
Circulation, April 8, 2003; 107(13): 1738 - 1743.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
W. Y. Kim, P. G. Danias, M. Stuber, S. D. Flamm, S. Plein, E. Nagel, S. E. Langerak, O. M. Weber, E. M. Pedersen, M. Schmidt, et al.
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
N. Engl. J. Med., December 27, 2001; 345(26): 1863 - 1869.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2000 by the Radiological Society of North America.