Vascular and Interventional Radiology |
1 From the Departments of Epidemiology (P.J.N., H.C.W.d.V.) and Radiology (T.L., J.M.A.v.E.), University of Maastricht, P Debyeplein 1, 6229 HA Maastricht, the Netherlands; and the Cochrane Methods Group on Systematic Review of Screening and Diagnostic Tests (H.C.W.d.V.). Received November 24, 1998; revision requested January 26, 1999; final revision received January 18; accepted February 7. Address correspondence to P.J.N. (e-mail: patty.nelemans@epid.unimaas.nl).
PURPOSE: To summarize the overall diagnostic performance of magnetic resonance (MR) angiography in the evaluation of peripheral arteriosclerotic occlusive disease and to identify the most important sources of variation in diagnostic accuracy between studies.
MATERIALS AND METHODS: A search strategy in MEDLINE and citation tracking were used to identify relevant English-language articles published since 1991. Each article was critically appraised for examination, patient, and study design characteristics. The accuracy data from different studies were analyzed by constructing summary receiver operating characteristic curves; multiple linear regression was used to examine the variation between study results.
RESULTS: Twenty-three studies were included. There was much heterogeneity in the study results, which could not be explained as differences in the threshold for a positive result. About half of the variation was due to the type of MR angiographic examination and the extent of image evaluation. The relative diagnostic odds ratio (DOR) for three-dimensional (3D) gadolinium-enhanced MR angiography compared with two-dimensional (2D) time-of-flight MR angiography was 7.46 (95% CI: 2.48, 22.20). The relative DOR for review of transverse source images or multiplanar reformations in addition to maximum intensity projections (MIPs) compared with the use of only MIPs for image evaluation was 4.53 (95% CI: 1.46, 13.87).
CONCLUSION: The diagnostic accuracy of 3D gadolinium-enhanced MR angiography is superior to that of 2D time-of-flight MR angiography. Also, the review of transverse source images or use of additional postprocessing techniques, such as multiplanar reformation, results in significantly better diagnostic performance.
Index terms: Arteries, MR, 91.12942, 91.12943, 92.12942, 92.12943 Arteries, peripheral, 91.721, 92.721 Arteries, stenoses or obstruction, 91.721, 92.721 Arteriosclerosis, 91.721, 92.721 Magnetic resonance (MR), comparative studies Magnetic resonance (MR), technology Receiver operating characteristic (ROC) curve
This article has been cited by other articles:
![]() |
M. Miyazaki and V. S. Lee Nonenhanced MR Angiography Radiology, July 1, 2008; 248(1): 20 - 43. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Thurnher, S. Miller, G. Schneider, C. Ballarati, G. Bongartz, C. U. Herborn, S. Schoenberg, M. A. Cova, G. Morana, K. Niazi, et al. Diagnostic Performance of Gadobenate Dimeglumine Enhanced MR Angiography of the Iliofemoral and Calf Arteries: A Large-Scale Multicenter Trial Am. J. Roentgenol., November 1, 2007; 189(5): 1223 - 1237. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Albrecht, E. Foert, R. Holtkamp, M. A. Kirchin, C. Ribbe, F. K. Wacker, M. Kruschewski, and B. C. Meyer 16-MDCT Angiography of Aortoiliac and Lower Extremity Arteries: Comparison with Digital Subtraction Angiography Am. J. Roentgenol., September 1, 2007; 189(3): 702 - 711. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Fenchel, R. Saleh, H. Dinh, M. H. Lee, K. Nael, M. Krishnam, S. G. Ruehm, S. Miller, J. Child, and J. P. Finn Juvenile and Adult Congenital Heart Disease: Time-resolved 3D Contrast-enhanced MR Angiography Radiology, August 1, 2007; 244(2): 399 - 410. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Cina, R. Ouwendijk, and M. G. M. Hunink First Challenge of MR versus CT Peripheral Angiography: How to Identify a Winner? Radiology, July 1, 2006; 240(1): 302 - 304. [Full Text] [PDF] |
||||
![]() |
P. J. Schaefer, F. P. Boudghene, H. J. Brambs, M. Bret-Zurita, J. L. Caniego, R. A. Coulden, H. B. Gehl, R. Hammerstingl, A. Huber, R. J. Mendez, et al. Abdominal and Iliac Arterial Stenoses: Comparative Double-blinded Randomized Study of Diagnostic Accuracy of 3D MR Angiography with Gadodiamide or Gadopentetate Dimeglumine Radiology, March 1, 2006; 238(3): 827 - 840. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. W.S. Rutjes, J. B. Reitsma, M. Di Nisio, N. Smidt, J. C. van Rijn, and P. M.M. Bossuyt Evidence of bias and variation in diagnostic accuracy studies. Can. Med. Assoc. J., February 14, 2006; 174(4): 469 - 476. [Abstract] [Full Text] [PDF] |
||||
![]() |
P S Sidhu, P L Allan, F Cattin, D O Cosgrove, A H Davies, D D Do, S Karakagil, J Langholz, D A Legemate, A Martegani, et al. Diagnostic efficacy of SonoVue(R), a second generation contrast agent, in the assessment of extracranial carotid or peripheral arteries using colour and spectral Doppler ultrasound: a multicentre study Br. J. Radiol., January 1, 2006; 79(937): 44 - 51. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Bipat, M. S. van Leeuwen, E. F. I. Comans, M. E. J. Pijl, P. M. M. Bossuyt, A. H. Zwinderman, and J. Stoker Colorectal Liver Metastases: CT, MR Imaging, and PET for Diagnosis--Meta-analysis Radiology, October 1, 2005; 237(1): 123 - 131. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Leiner, A. G. H. Kessels, P. J. Nelemans, G. B. C. Vasbinder, M. W. de Haan, P. E. J. H. M. Kitslaar, K. Y. J. A. M. Ho, J. H. M. Tordoir, and J. M. A. van Engelshoven Peripheral Arterial Disease: Comparison of Color Duplex US and Contrast-enhanced MR Angiography for Diagnosis Radiology, May 1, 2005; 235(2): 699 - 708. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Baumgartner, H. C. Thoeny, O. Kummer, C. Roefke, C. Skjelsvik, C. Boesch, and R. Kreis Leg Ischemia: Assessment with MR Angiography and Spectroscopy Radiology, March 1, 2005; 234(3): 833 - 841. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Bezooijen, H. C. M. van den Bosch, A. V. Tielbeek, G. R. P. Thelissen, K. Visser, M. G. M. Hunink, L. E. M. Duijm, J. Wondergem, J. Buth, and P. W. M. Cuypers Peripheral Arterial Disease: Sensitivity-encoded Multiposition MR Angiography Compared with Intraarterial Angiography and Conventional Multiposition MR Angiography Radiology, April 1, 2004; 231(1): 263 - 271. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M Bossuyt, J. B Reitsma, D. E Bruns, C. A Gatsonis, P. P Glasziou, L. M Irwig, J. G Lijmer, D. Moher, D. Rennie, and H. C. de Vet Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative Fam. Pract., February 1, 2004; 21(1): 4 - 10. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Ota, K. Takase, K. Igarashi, Y. Chiba, K. Haga, H. Saito, and S. Takahashi MDCT Compared with Digital Subtraction Angiography for Assessment of Lower Extremity Arterial Occlusive Disease: Importance of Reviewing Cross-Sectional Images Am. J. Roentgenol., January 1, 2004; 182(1): 201 - 209. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Bossuyt, J. B. Reitsma, D. E. Bruns, C. A. Gatsonis, P. P. Glasziou, L. M. Irwig, J. G. Lijmer, D. Moher, D. Rennie, and H. C. W. de Vet Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative Am. J. Roentgenol., July 1, 2003; 181(1): 51 - 55. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Visser, M. C. J. M. Kock, K. M. Kuntz, M. C. Donaldson, G. S. Gazelle, and M. G. Myriam Hunink Cost-effectiveness Targets for Multi-Detector Row CT Angiography in the Work-up of Patients with Intermittent Claudication Radiology, June 1, 2003; 227(3): 647 - 656. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Bossuyt, J. B. Reitsma, D. E. Bruns, C. A. Gatsonis, P. P. Glasziou, L. M. Irwig, J. G. Lijmer, D. Moher, D. Rennie, H. C.W. de Vet, et al. Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative Ann Intern Med, January 7, 2003; 138(1): 40 - 44. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M Bossuyt, J. B Reitsma, D. E Bruns, C. A Gatsonis, P. P Glasziou, L. M Irwig, J. G Lijmer, D. Moher, D. Rennie, and H. C W de Vet Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative BMJ, January 4, 2003; 326(7379): 41 - 44. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Bossuyt, J. B. Reitsma, D. E. Bruns, C. A. Gatsonis, P. P. Glasziou, L. M. Irwig, J. G. Lijmer, D. Moher, D. Rennie, and H. C.W. de Vet Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative Clin. Chem., January 1, 2003; 49(1): 1 - 6. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Bossuyt, J. B. Reitsma, D. E. Bruns, C. A Gatsonis, P. P. Glasziou, L. M. Irwig, J. G. Lijmer, D. Moher, D. Rennie, and H. C. W. de Vet Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative Radiology, January 1, 2003; 226(1): 24 - 28. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Loewe, M. Schoder, T. Rand, U. Hoffmann, J. Sailer, T. Kos, J. Lammer, and S. Thurnher Peripheral Vascular Occlusive Disease: Evaluation with Contrast-Enhanced Moving-Bed MR Angiography Versus Digital Subtraction Angiography in 106 Patients Am. J. Roentgenol., October 1, 2002; 179(4): 1013 - 1021. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Huo, M. L. Giger, C. J. Vyborny, and C. E. Metz Breast Cancer: Effectiveness of Computer-aided Diagnosis—Observer Study with Independent Database of Mammograms Radiology, August 1, 2002; 224(2): 560 - 568. [Abstract] [Full Text] [PDF] |
||||