Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Serfaty, J.-M.
Right arrow Articles by Yang, X.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Serfaty, J.-M.
Right arrow Articles by Yang, X.
(Radiology. 2000;217:290-295.)
© RSNA, 2000


Technical Developments

Real-time Projection MR Angiography: Feasibility Study1

Jean-Michel Serfaty, MD, Ergin Atalar, PhD, Jerome Declerck, PhD, Perry Karmakar, MS, Harald H. Quick, MS, Kendrick A. Shunk, MD, Alan W. Heldman, MD and Xiaoming Yang, MD, PhD

1 From the Departments of Radiology and Biomedical Engineering, (J.M.S., E.A., P.K., H.H.Q., X.Y.), Biomedical Engineering (J.D.), and Division of Cardiology (K.A.S., A.W.H.), Johns Hopkins University School of Medicine, Outpatient Center, Room 4243, 601 North Caroline St, Baltimore, MD 21287-0845. Received May 26, 1999; revision requested July 19; final revision received December 15; accepted January 17, 2000. Supported in part by a Lavoisier Program grant (J.M.S.), a Société Francaise de Radiologie grant (J.M.S.), National Institutes of Health RO1HL61672 grant (E.A.), and National Institutes of Health R29HL57483 grant (E.A.). Address correspondence to X.Y. (e-mail: xyang@mri.jhu.edu).

Intraarterial injections of small doses of gadopentetate dimeglumine were combined with a fast spoiled-gradient-echo magnetic resonance (MR) sequence to obtain real-time projection angiographic images of the rabbit aorta and canine coronary arteries. Arterial filling and washout, as well as venous and perfusion phases, were clearly displayed, demonstrating that arterial fluoroscopy in which an MR technique is used is feasible.

Index terms: Angiography, contrast media, 50.121412, 50.12142, 54.121412, 54.12142 • Gadolinium, 50.121412, 50.12142, 54.121412, 54.12142 • Magnetic resonance (MR), contrast enhancement, 50.121412, 50.12142, 54.121412, 54.12142 • Magnetic resonance (MR), guidance • Magnetic resonance (MR), vascular studies, 50.121412, 50.12142, 54.121412, 54.12142




This article has been cited by other articles:


Home page
RadiologyHome page
A. Arepally, P. V. Karmarkar, C. Weiss, and E. Atalar
Percutaneous MR Imaging-guided Transvascular Access of Mesenteric Venous System: Study in Swine Model
Radiology, January 1, 2006; 238(1): 113 - 118.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. Zorger, M. Volk, O. W. Hamer, M. Lenhart, J. Seitz, B. Butz, and C. Paetzel
Intraarterial Gadolinium-Enhanced MR Angiography in Humans for the Detection of Infrainguinal Arterial Stenoses Before and After Percutaneous Angioplasty
Am. J. Roentgenol., October 1, 2005; 185(4): 867 - 872.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A.-C. Schulte, G. Bongartz, R. Huegli, M. Aschwanden, K. A. Jaeger, W. Ostheim-Dzerowycz, A. L. Jacob, and D. Bilecen
Intraarterial Versus IV Gadolinium Injections for MR Angiography: Quantitative and Qualitative Assessment of the Infrainguinal Arteries
Am. J. Roentgenol., September 1, 2005; 185(3): 735 - 740.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Bilecen, A.-C. Schulte, H. G. Heidecker, M. Aschwanden, R. Huegli, K. A. Jaeger, W. Ostheim-Dzerowycz, and G. Bongartz
Lower Extremity: Low-Dose Contrast Agent Intraarterial MR Angiography in Patients--Initial Results
Radiology, January 1, 2005; 234(1): 250 - 255.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. Hager, H. Kaemmerer, A. Leppert, M. Prokop, S. Blucher, H. Stern, and J. Hess
Follow-up of Adults With Coarctation of the Aorta: Comparison of Helical CT and MRI, and Impact on Assessing Diameter Changes
Chest, October 1, 2004; 126(4): 1169 - 1176.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. K. Wacker, R. M. Maes, J. A. Jesberger, S. G. Nour, J. L. Duerk, and J. S. Lewin
MR Imaging-Guided Vascular Procedures Using CO2 as a Contrast Agent
Am. J. Roentgenol., August 1, 2003; 181(2): 485 - 489.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. A. Omary, J. D. Green, B. E. Schirf, Y. Li, J. P. Finn, and D. Li
Real-Time Magnetic Resonance Imaging-Guided Coronary Catheterization in Swine
Circulation, June 3, 2003; 107(21): 2656 - 2659.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. D. Green, R. A. Omary, J. P. Finn, Y.-C. Chung, R. Tang, Y. Li, S. Vasireddy, and D. Li
Two- and Three-dimensional MR Coronary Angiography with Intraarterial Injections of Contrast Agent in Dogs: A Feasibility Study
Radiology, January 1, 2003; 226(1): 272 - 277.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. J. Lederman, M. A. Guttman, D. C. Peters, R. B. Thompson, J. M. Sorger, A. J. Dick, V. K. Raman, and E. R. McVeigh
Catheter-Based Endomyocardial Injection With Real-Time Magnetic Resonance Imaging
Circulation, March 19, 2002; 105(11): 1282 - 1284.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. A. Omary, K. P. Henseler, O. Unal, L. J. Maciolek, J. P. Finn, D. Li, A. A. Nemcek Jr., R. L. Vogelzang, and T. M. Grist
Comparison of Intraarterial and IV Gadolinium-Enhanced MR Angiography with Digital Subtraction Angiography for the Detection of Renal Artery Stenosis in Pigs
Am. J. Roentgenol., January 1, 2002; 178(1): 119 - 123.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
S. B. Reeder, Y. P. Du, J. A. C. Lima, and D. A. Bluemke
Advanced Cardiac MR Imaging of Ischemic Heart Disease
RadioGraphics, July 1, 2001; 21(4): 1047 - 1074.
[Abstract] [Full Text] [PDF]