Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yang, X.
Right arrow Articles by Atalar, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yang, X.
Right arrow Articles by Atalar, E.
(Radiology. 2000;217:501-506.)
© RSNA, 2000


Experimental Studies

Intravascular MR Imaging-guided Balloon Angioplasty With an MR Imaging Guide Wire: Feasibility Study in Rabbits1

Xiaoming Yang, MD, PhD and Ergin Atalar, PhD

1 From the Department of Radiology, Johns Hopkins University School of Medicine, Outpatient Center Rm 4243, 601 N Caroline St, Baltimore MD 21287-0845. Received September 21, 1999; revision requested November 1; final revision received February 4, 2000; accepted February 22. Supported in part by National Institutes of Health grant number R29HL57483, the Whitaker Foundation, and Surgi-Vision. Address correspondence to X.Y. (e-mail: xyang@mri.jhu.edu).

PURPOSE: To develop a technique for intravascular magnetic resonance (MR)–guided balloon angioplasty with use of an MR imaging guide wire.

MATERIALS AND METHODS: An MR imaging guide wire (0.6-mm loopless antenna) that could be placed within a balloon catheter was manufactured. The guide wire was expected to function as either an MR receiver probe in real-time MR imaging or a guide wire for use with interventional devices. Laparotomy was performed in eight rabbits, and a dilatable stenosis was created at the upper abdominal aorta. Balloon angioplasty, validated at pre- and postoperative MR aortography with renal contrast enhancement was performed by using a 1.5-T MR unit with a fast spoiled gradient-echo pulse sequence, short repetition and echo times, and a rate of three frames per second.

RESULTS: During MR tracking, the entire length of the MR imaging guide wire was always visible as a band of high signal intensity. In all cases, the MR imaging guide wires were passed through the aortic stenoses dilated by means of balloon inflation. Before balloon angioplasty, flow in the aorta distal to the stenosis was decreased, which caused mild contrast enhancement in each kidney. After balloon angioplasty, distal flow was restored, resulting in substantial renal enhancement.

CONCLUSION: The MR imaging guide wire is a potential tool for use in endovascular interventional MR imaging.

Index terms: Animals • Interventional procedures, experimental studies, 943.1282, 943.7229 • Magnetic resonance (MR), contrast enhancement, 943.12943, 961.12943 • Magnetic resonance (MR), guidance, 943.1282 • Magnetic resonance (MR), vascular studies, 81.129412, 81.12942, 81.12943, 943.129412, 943.12942, 943.12943




This article has been cited by other articles:


Home page
CirculationHome page
J. J. Krueger, P. Ewert, S. Yilmaz, D. Gelernter, B. Peters, K. Pietzner, A. Bornstedt, B. Schnackenburg, H. Abdul-Khaliq, E. Fleck, et al.
Magnetic Resonance Imaging-Guided Balloon Angioplasty of Coarctation of the Aorta: A Pilot Study
Circulation, February 28, 2006; 113(8): 1093 - 1100.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
X. Du, B. Qiu, X. Zhan, A. Kolmakova, F. Gao, L. V. Hofmann, L. Cheng, S. Chatterjee, and X. Yang
Radiofrequency-enhanced Vascular Gene Transduction and Expression for Intravascular MR Imaging-guided Therapy: Feasibility Study in Pigs
Radiology, September 1, 2005; 236(3): 939 - 944.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. A. Krombach, J. G. Pfeffer, S. Kinzel, M. Katoh, R. W. Gunther, and A. Buecker
MR-guided Percutaneous Intramyocardial Injection with an MR-compatible Catheter: Feasibility and Changes in T1 Values after Injection of Extracellular Contrast Medium in Pigs
Radiology, May 1, 2005; 235(2): 487 - 494.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. W. Olin, J. A. Kaufman, D. A. Bluemke, R. O. Bonow, M. D. Gerhard, M. R. Jaff, G. D. Rubin, and W. Hall
Atherosclerotic Vascular Disease Conference: Writing Group IV: Imaging
Circulation, June 1, 2004; 109(21): 2626 - 2633.
[Full Text] [PDF]


Home page
RadiologyHome page
X. Yang
Imaging of Vascular Gene Therapy
Radiology, July 1, 2003; 228(1): 36 - 49.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Kuehne, M. Saeed, C. B. Higgins, K. Gleason, G. A. Krombach, O. M. Weber, A. J. Martin, D. Turner, D. Teitel, and P. Moore
Endovascular Stents in Pulmonary Valve and Artery in Swine: Feasibility Study of MR Imaging-guided Deployment and Postinterventional Assessment
Radiology, February 1, 2003; 226(2): 475 - 481.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
R. P. Choudhury, V. Fuster, J. J. Badimon, E. A. Fisher, and Z. A. Fayad
MRI and Characterization of Atherosclerotic Plaque: Emerging Applications and Molecular Imaging
Arterioscler. Thromb. Vasc. Biol., July 1, 2002; 22(7): 1065 - 1074.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
X. Yang, E. Atalar, D. Li, J.-M. Serfaty, D. Wang, A. Kumar, and L. Cheng
Magnetic Resonance Imaging Permits In Vivo Monitoring of Catheter-Based Vascular Gene Delivery
Circulation, October 2, 2001; 104(14): 1588 - 1590.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2000 by the Radiological Society of North America.