Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bavelaar-Croon, C. D. L.
Right arrow Articles by Atsma, D. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bavelaar-Croon, C. D. L.
Right arrow Articles by Atsma, D. E.
(Radiology. 2000;217:572-575.)
© RSNA, 2000


Technical Developments

Left Ventricular Function: Correlation of Quantitative Gated SPECT and MR Imaging over a Wide Range of Values1

Carine D. L. Bavelaar-Croon, MD, Hein W. M. Kayser, MD, Ernst E. van der Wall, MD, PhD, Albert de Roos, MD, PhD, Petra Dibbets-Schneider, CNMTM, Ernest K. J. Pauwels, PhD, Guido Germano, PhD and Douwe E. Atsma, MD, PhD

1 From the Department of Radiology (H.W.M.K., A.d.R.), Divisions of Nuclear Medicine (C.D.L.B.C., P.D.S., E.K.J.P.) and Cardiology (E.E.v.d.W., D.E.A.), Leiden University Medical Centre, Albinusdreef 2, C4Q-80, 2333 ZA Leiden, the Netherlands; and the Division of Nuclear Medicine, Cedars-Sinai Medical Center, Los Angeles, Calif (G.G.). Received November 10, 1999; revision requested December 15; revision received February 7, 2000; accepted March 30. Address correspondence to C.D.L.B.C. (e-mail: C.Bavelaar-Croon@inter.nl.net).

In 21 patients, the authors compared results with quantitative gated single photon emission computed tomography (SPECT) to results with magnetic resonance imaging in the assessment of left ventricular (LV) end-diastolic volume (LVEDV), end-systolic volume (LVESV), and ejection fraction (LVEF). Between the two methods, correlations were good for LVEF (r = 0.85), LVEDV (r = 0.94), and LVESV (r = 0.95). Quantitative gated SPECT can help determine LVEF, LVEDV, and LVESV.

Index terms: Heart, function, 524.91 • Heart, MR, 524.121412 • Heart, SPECT, 524.12162 • Heart, ventricles, 524.121412, 524.12162, 524.91 • Heart, volume, 524.121412, 524.12162 • Magnetic resonance (MR), comparative studies, 524.121412, 524.1262




This article has been cited by other articles:


Home page
JNMHome page
D. Knollmann, O. H. Winz, P. T. Meyer, M. Raptis, T. Krohn, K.-C. Koch, and W. M. Schaefer
Gated Myocardial Perfusion SPECT: Algorithm-Specific Influence of Reorientation on Calculation of Left Ventricular Volumes and Ejection Fraction
J. Nucl. Med., October 1, 2008; 49(10): 1636 - 1642.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M S KRISHNAM, A TOMASIAN, M. Iv, S G RUEHM, R SALEH, C PANKNIN, and J G GOLDIN
Left ventricular ejection fraction using 64-slice CT coronary angiography and new evaluation software: initial experience
Br. J. Radiol., June 1, 2008; 81(966): 450 - 455.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Schepis, O. Gaemperli, P. Koepfli, I. Valenta, K. Strobel, A. Brunner, S. Leschka, L. Desbiolles, L. Husmann, H. Alkadhi, et al.
Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
J. Nucl. Med., August 1, 2006; 47(8): 1288 - 1294.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. M. Schaefer, C. S.A. Lipke, D. Standke, H. P. Kuhl, B. Nowak, H.-J. Kaiser, K.-C. Koch, and U. Buell
Quantification of Left Ventricular Volumes and Ejection Fraction from Gated 99mTc-MIBI SPECT: MRI Validation and Comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT
J. Nucl. Med., August 1, 2005; 46(8): 1256 - 1263.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Yamamuro, E. Tadamura, S. Kubo, H. Toyoda, T. Nishina, M. Ohba, R. Hosokawa, T. Kimura, N. Tamaki, M. Komeda, et al.
Cardiac Functional Analysis with Multi-Detector Row CT and Segmental Reconstruction Algorithm: Comparison with Echocardiography, SPECT, and MR Imaging
Radiology, February 1, 2005; 234(2): 381 - 390.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
A. K. Paul and H. A. Nabi
Gated Myocardial Perfusion SPECT: Basic Principles, Technical Aspects, and Clinical Applications
J. Nucl. Med. Technol., December 1, 2004; 32(4): 179 - 187.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. M. Schaefer, C. S.A. Lipke, H. P. Kuhl, K.-C. Koch, H.-J. Kaiser, P. Reinartz, B. Nowak, and U. Buell
Prone Versus Supine Patient Positioning During Gated 99mTc-Sestamibi SPECT: Effect on Left Ventricular Volumes, Ejection Fraction, and Heart Rate
J. Nucl. Med., December 1, 2004; 45(12): 2016 - 2020.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S.R. Underwood, J. J Bax, J. v. Dahl, M. Y Henein, A. C van Rossum, E. R Schwarz, J.-L. Vanoverschelde, E. E.v. d. Wall, and W. Wijns
Imaging techniques for the assessment of myocardial hibernation: Report of a Study Group of the European Society of Cardiology
Eur. Heart J., May 2, 2004; 25(10): 815 - 836.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
V. Go, M. R. Bhatt, and R. C. Hendel
The Diagnostic and Prognostic Value of ECG-Gated SPECT Myocardial Perfusion Imaging
J. Nucl. Med., May 1, 2004; 45(5): 912 - 921.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. P. A. Ioannidis, T. A. Trikalinos, and P. G. Danias
Electrocardiogram-gated single-photonemission computed tomography versus cardiacmagnetic resonance imaging for the assessmentof left ventricular volumes and ejection fraction: A meta-analysis
J. Am. Coll. Cardiol., June 19, 2002; 39(12): 2059 - 2068.
[Abstract] [Full Text] [PDF]