Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weatherburn, G. C.
Right arrow Articles by Davies, J. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weatherburn, G. C.
Right arrow Articles by Davies, J. G.
(Radiology. 2000;217:707-712.)
© RSNA, 2000


Medical Physics

Comparison of Doses for Bedside Examinations of the Chest with Conventional Screen-Film and Computed Radiography: Results of a Randomized Controlled Trial1

Gwyneth C. Weatherburn, PhD, Stirling Bryan, PhD 2 and J. Glyn Davies, MSc 3

1 From the Health Economics Research Group, Brunel University, Uxbridge, Middlesex UB8 3PH, England. Received February 9, 2000; revision requested March 17; revision received April 25; accepted May 1. Supported by the Wales Office of Research and Development for Health and Social Care. Address correspondence to G.C.W. (e-mail: gwyneth.weatherburn@brunel.ac.uk).

PURPOSE: To compare the radiation doses received by patients during bedside chest radiography when a computed radiography system was used and when a 400-speed screen-film system was used.

MATERIALS AND METHODS: A randomized controlled trial was performed whereby all patients who were admitted to an intensive care unit were randomly assigned at admission to have all radiographic chest images obtained with either computed or conventional screen-film radiography. Doses were measured for 1 year, during which 269 patients underwent imaging. For these patients, surface entry doses were measured by means of individual thermoluminescent dosimeters placed on the skin at the center of the radiation beam. In addition, data were collected relating to the patient and examination characteristics, as well as to repeat examinations. Effective doses were calculated.

RESULTS: The patients in the two arms of the study were well matched. The surface entry doses were higher in the computed radiography group (median, 0.21 mGy for computed radiography and 0.16 mGy for conventional radiography), and the effective doses were also higher (median, 0.036 mSv for computed radiography and 0.027 mSv for conventional radiography). Fewer examinations were repeated when computed radiography was used.

CONCLUSION: When computed radiography was used, patient doses increased. The speed of this computed radiography system, which uses phosphor plate imaging, equates approximately to a 300-speed screen-film system.

Index terms: Radiations, exposure to patients and personnel • Radiography, bedside, **.114 • Radiography, comparative studies, **.11 • Radiography, computer-assisted, **.11 • Radiography, storage phosphor, **.11 • Thorax, abnormalities, **.11 • Thorax, radiography, **.11




This article has been cited by other articles:


Home page
RadioGraphicsHome page
M. Korner, C. H. Weber, S. Wirth, K.-J. Pfeifer, M. F. Reiser, and M. Treitl
Advances in Digital Radiography: Physical Principles and System Overview
RadioGraphics, May 1, 2007; 27(3): 675 - 686.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Vano, J. M. Fernandez, J. I. Ten, C. Prieto, L. Gonzalez, R. Rodriguez, and H. de Las Heras
Transition from Screen-Film to Digital Radiography: Evolution of Patient Radiation Doses at Projection Radiography
Radiology, May 1, 2007; 243(2): 461 - 466.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
G Compagnone, M C. Baleni, L Pagan, F L Calzolaio, L Barozzi, and C Bergamini
Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography.
Br. J. Radiol., November 1, 2006; 79(947): 899 - 904.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. Mazzocchi, G. Belli, S. Busoni, C. Gori, I. Menchi, P. Salucci, A. Taddeucci, and G. Zatelli
AEC set-up optimisation with computed radiography imaging
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 169 - 173.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Neofotistou, V. Tsapaki, S. Kottou, A. Schreiner-Karoussou, and E. Vano
Does digital imaging decrease patient dose? A pilot study and review of the literature
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 204 - 210.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
L Gonzalez, R Fernandez, V Ziraldo, E Vano, and R Ortega
Reference level for patient dose in dental skull lateral teleradiography
Br. J. Radiol., September 1, 2004; 77(921): 735 - 739.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Vano, J. M. Fernandez, J. I. Ten, E. Guibelalde, L. Gonzalez, and C. S. A. Pedrosa
Real-Time Measurement and Audit of Radiation Dose to Patients Undergoing Computed Radiography
Radiology, October 1, 2002; 225(1): 283 - 288.
[Abstract] [Full Text] [PDF]