Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kalyanpur, A.
Right arrow Articles by Brink, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kalyanpur, A.
Right arrow Articles by Brink, J. A.
(Radiology. 2000;217:772-779.)
© RSNA, 2000


Computer Applications

Evaluation of JPEG and Wavelet Compression of Body CT Images for Direct Digital Teleradiologic Transmission1

Arjun Kalyanpur, MD, Vladimir P. Neklesa, MD, Caroline R. Taylor, MD, Aditya R. Daftary, MB, BS and James A. Brink, MD

1 From the Department of Diagnostic Radiology, Yale University School of Medicine, 2-332 SP, 333 Cedar St, New Haven, CT 06520. Received October 27, 1999; revision requested December 7; revision received April 6, 2000; accepted April 20. Address correspondence to J.A.B. (e-mail: James.Brink@yale.edu).

PURPOSE: To determine acceptable levels of JPEG (Joint Photographic Experts Group) and wavelet compression for teleradiologic transmission of body computed tomographic (CT) images.

MATERIALS AND METHODS: A digital test pattern (Society of Motion Picture and Television Engineers, 512 x 512 matrix) was transmitted after JPEG or wavelet compression by using point-to-point and Web-based teleradiology, respectively. Lossless, 10:1 lossy, and 20:1 lossy ratios were tested. Images were evaluated for high- and low-contrast resolution, sensitivity to small signal differences, and misregistration artifacts. Three independent observers who were blinded to the compression scheme evaluated these image quality measures in 20 clinical cases with similar levels of compression.

RESULTS: High-contrast resolution was not diminished with any tested level of JPEG or wavelet compression. With JPEG compression, low-contrast resolution was not lost with 10:1 lossy compression but was lost at 3% modulation with 20:1 lossy compression. With wavelet compression, there was loss of 1% modulation with 10:1 lossy compression and loss of 5% modulation with 20:1 lossy compression. Sensitivity to small signal differences (5% and 95% of the maximal signal) diminished only with 20:1 lossy wavelet compression. With 10:1 lossy compression, misregistration artifacts were mild and were equivalent with JPEG and wavelet compression. Qualitative clinical findings supported these findings.

CONCLUSION: Lossy 10:1 compression is suitable for on-call electronic transmission of body CT images as long as original images are subsequently reviewed.

Index terms: Computed tomography (CT), image processing, **.121122 • Computed tomography (CT), image quality, **.1211 • Data compression • Images, storage and retrieval • Images, transmission • Phantoms • Teleradiology




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
V. Bajpai, K. H. Lee, B. Kim, K. J. Kim, T. J. Kim, Y. H. Kim, and H. S. Kang
Differences in Compression Artifacts on Thin- and Thick-Section Lung CT Images
Am. J. Roentgenol., August 1, 2008; 191(2): W38 - W43.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Ringl, R. Schernthaner, E. Sala, K. El-Rabadi, M. Weber, W. Schima, C. J. Herold, and A. K. Dixon
Lossy 3D JPEG2000 Compression of Abdominal CT Images in Patients with Acute Abdominal Complaints: Effect of Compression Ratio on Diagnostic Confidence and Accuracy
Radiology, August 1, 2008; 248(2): 476 - 484.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Kim, K. H. Lee, K. J. Kim, R. Mantiuk, H.-r. Kim, and Y. H. Kim
Artifacts in Slab Average-Intensity-Projection Images Reformatted from JPEG 2000 Compressed Thin-Section Abdominal CT Data Sets
Am. J. Roentgenol., June 1, 2008; 190(6): W342 - W350.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Ringl, R. E. Schernthaner, C. Kulinna-Cosentini, M. Weber, C. Schaefer-Prokop, C. J. Herold, and W. Schima
Lossy Three-dimensional JPEG2000 Compression of Abdominal CT Images: Assessment of the Visually Lossless Threshold and Effect of Compression Ratio on Image Quality
Radiology, November 1, 2007; 245(2): 467 - 474.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Suryanarayanan, A. Karellas, S. Vedantham, S. M. Waldrop, and C. J. D'Orsi
Detection of Simulated Lesions on Data-compressed Digital Mammograms
Radiology, July 1, 2005; 236(1): 31 - 36.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Kalyanpur, V. P. Neklesa, D. T. Pham, H. P. Forman, S. T. Stein, and J. A. Brink
Implementation of an International Teleradiology Staffing Model
Radiology, August 1, 2004; 232(2): 415 - 419.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Ko, H. Rusinek, D. P. Naidich, G. McGuinness, A. N. Rubinowitz, B. S. Leitman, and J. M. Martino
Wavelet Compression of Low-Dose Chest CT Data: Effect on Lung Nodule Detection
Radiology, July 1, 2003; 228(1): 70 - 75.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2000 by the Radiological Society of North America.